Failed Double Studded Adapter (Choke Manifold Test – 4 th test @ 10,000 psi; equipment failed)

Failed Double Studded Adapter (Choke Manifold Test – 4 th test @ 10,000 psi; equipment failed). Rig Commissioning – Yard (Jan 28, 2010) New double studded adapter (DSA) delivered from pressure testers – ‘ready to go’

sydnee-holt
Download Presentation

Failed Double Studded Adapter (Choke Manifold Test – 4 th test @ 10,000 psi; equipment failed)

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Failed Double Studded Adapter(Choke Manifold Test – 4th test @ 10,000 psi; equipment failed) Rig Commissioning – Yard (Jan 28, 2010) • New double studded adapter (DSA) delivered from pressure testers – ‘ready to go’ • Made up the equipment and readied for testing ~ failed at +/- 10,000 psi (5 minutes into a 10 minute test) Root Cause – Failure • Studs not made-up to the DSA properly – had < ½” make-up • No equipment verification ~ both ‘long bolting / short bolting’ evident Action – Everyone • Trust-n-verify ~ ensure equipment is inspected & ready to go • Question stud length anomalies (upon make-up) • Establish & maintain buffer zones • Ensure CoW 4 1/16” 10K x 2 1/16” 10K DSA Barely threaded into DSA For more information contact: Don McKelvey 1-307-413-4585

More Related