1 / 1

Sponsors: David Cadogan Scott Davidson Advisor: Dr. Michael Keefe

Position Sensing Glove. Sponsors: David Cadogan Scott Davidson Advisor: Dr. Michael Keefe. Background:. Final Concept:. Proof of Concept Prototype:.

Download Presentation

Sponsors: David Cadogan Scott Davidson Advisor: Dr. Michael Keefe

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Position Sensing Glove Sponsors: David Cadogan Scott DavidsonAdvisor: Dr. Michael Keefe Background: Final Concept: Proof of Concept Prototype: Team 6: Barbara Tuday Nathan Schreppler Michael Nolan Lauren McIlwain Glove with Model Sensors and Securing Devices: Circuit Diagram and Test Setup: LabView DAQ Program: During a hand therapy session, physical therapists must manually measure the angle of each joint in a patient’s hand and wrist. Problem Statement: Our goal is to design, develop, produce, and test a prototypic, low-cost, and functional glove that will sense key finger, thumb, and wrist positions using compliant advanced technologies. Testing: • Attachment of sensors • Effect of backing thickness • Need for electrical connection stiffener • Behavior of sensors: • Tension Test • Bend Radius Test • Pressure Test • Twist Test Concept Selection: Glove with Sensors: Top Ten Wants: • Key Customers: • ILC Dover • Physical Therapists • Patients Results: • Optimal backing is the medium-thickness backing (three layers of packing tape). • No effect from pressure. • Minimal effects from tension and twist. • Bend radius has no effect on voltage readings. • An electrical connection stiffener is necessary for consistent results. Features: Subsystems: • Spectra Symbol flex sensors glued to a nylon knit comfort glove. • Sensors wired with 24 gauge wire to an eight- channel DAQ board. • Data collected using LabView, which will convert voltage readings to angular measurements. • Stiffeners made of polypropylene stabilize and protect the electrical connections on the sensors. Project Transition: Selected Concepts: • Sensors – Peratech “QTC” material • Wiring – Calmont brand wire • Glove – Knit “Comfort glove” • DAQ – LabView • Used in Prototype: • Sensors – Spectra Symbol flex sensors • Wiring – Copper wire • Replace Sensors with Peratech QTC Technology • Rewire with Calmont brand wire • Improve DAQ system (USB Port Input) • Improve LabView Program

More Related