1 / 57

OBS 13: Measuring Upper Tropospheric Humidity with Operational Microwave Satellite Sensors

OBS 13: Measuring Upper Tropospheric Humidity with Operational Microwave Satellite Sensors. COST 723 UTLS Summerschool Cargese, Corsica, Oct. 3-15, 2005 Stefan A. Buehler Institute of Environmental Physics University of Bremen www.sat.uni-bremen.de. Overview.

tacey
Download Presentation

OBS 13: Measuring Upper Tropospheric Humidity with Operational Microwave Satellite Sensors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. OBS 13: Measuring Upper Tropospheric Humidity with Operational Microwave Satellite Sensors COST 723 UTLS Summerschool Cargese, Corsica, Oct. 3-15, 2005 Stefan A. Buehler Institute of Environmental Physics University of Bremen www.sat.uni-bremen.de

  2. Overview • Water vapor in the Earths radiation balance • Operational meteorological microwave satellite instruments (AMSU-B) • AMSU-B measurements of upper tropospheric water vapor • Comparison with radiosonde measurements • Temperature uncertainty and supersaturation • The radiative transfer model ARTS • Summary Cited papers can be found at http://www.sat.uni-bremen.de

  3. Overview • Water vapor in the Earths radiation balance • Operational meteorological microwave satellite instruments (AMSU-B) • AMSU-B measurements of upper tropospheric water vapor • Comparison with radiosonde measurements • Temperature uncertainty and supersaturation • The radiative transfer model ARTS • Summary

  4. Earths Radiation Balance Sun Earth Incoming Shortwave Radiation Outgoing Longwave Radiation OLR

  5. Earths Radiation Balance λEλ [normalized] Wavelength [μm] (Wallace und Hobbs, `Atmospheric Science', Academic Press, 1977.) • Radiative equilibrium temperature: -18°C • Global mean surface temperature: +15°C • 34 K natural greenhouse effect

  6. Clear-Sky OLR Spectrum • A lot of the radiation comes from the UT • Water vapor and CO2 are the most important greenhouse gases

  7. Jacobians [10-14W Hz-1 sr-1 m-2]

  8. [10-14W Hz-1 sr-1 m-2] [10-14W Hz-1 sr-1 m-2] [10-14W Hz-1 sr-1 m-2] [10-14W Hz-1 sr-1 m-2]

  9. Important Altitude Range [10-14W Hz-1 sr-1 m-2] MLS • OLR is sensitive to changes of humidity in the upper troposphere, where it is difficult to measure. • Sensitivity peak below TTL.

  10. H2O is a stronger greenhouse gas than CO2 Impact on Tropical OLR 15% change in humidity = double CO2 - (for a tropical atmosphere) • Higher surface temperature = more evaporation positive feedback. (Buehler et al., JQSRT, submitted 2005)

  11. The Water Vapor Feedback • Convection and cyclones transport moisture into the UT (see lectures of Heini Wernli and Andrew Gettelman) • Ascending air is dried by condensation processes • High spatial and temporal variability • Residence time of water substance ~10 days

  12. Variability of Clear-Sky OLR • Paradox: More humidity = more OLR! Simulated OLR [W/m2] Total water vapor [mm] (Buehler et al., Q. J. R. Meteorol. Soc., submitted 2005)

  13. Variability of Clear-Sky OLR CERES Data Simulated OLR [W/m2] Radiosondes • High temperature correlated with high humidity • Positive temperature signal outweighs negative humidity signal • Expected, otherwise runaway greenhouse effect • Water vapor signal strongest in the tropics • Simulated radiances agree with CERES OLR data Surface temperature [K] (Buehler et al., Q. J. R. Meteorol. Soc., submitted 2005)

  14. Variability of Clear-Sky OLR CERES Data Simulated OLR [W/m2] Radiosondes Delta OLR [W/m2] • (Buehler et al., Q. J. R. Meteorol. Soc., submitted 2005) • No strong temperature variations in the tropics • Temperature and Water Vapor variations are both important for clear-sky OLR

  15. Climate GCMs indicate that the feedback is positive. • A large part (about half) of the warming predicted by models for a CO2 rise is due to the water vapor feedback (Held and Soden, Annu. Rev. Energy Environ., 2000). • The UT is an important altitude region for this feedback, but humidity there is poorly known. • Radiosonde measurements: • Low spatial coverage • Poor data quality in the UT • Infrared satellite measurements: • Good global coverage, but affected by clouds • Clear sky bias • Microwave satellite measurements (today) • Radio occultation (Friday, OBS 16) • Ice clouds play also an important role in the UT radiation balance (Friday, OBS 15)

  16. Big differences between the different data sets, for example: +/-15 %RH difference between IR satellite and radiosonde = 40% relative difference in humidity, as RH values are low in the UT. Comparison: Radiosondes ↔ Infrared Satellite Data (Soden and Lanzante, JGR 1996) Problem: Large discrepancies, true climatology unknown (see e.g. SPARC UTLS H2O Assessment)

  17. Overview • Water vapor in the Earths radiation balance • Operational meteorological microwave satellite instruments (AMSU-B) • AMSU-B measurements of upper tropospheric water vapor • Comparison with radiosonde measurements • Temperature uncertainty and supersaturation • The radiative transfer model ARTS • Summary

  18. Microwave Satellite Data • SSM-T2 since 1995 • AMSU-B since 1999 • Passive microwave instruments (measuring thermal radiation from the atmosphere) • Less affected by cloud than infrared • Well calibrated

  19. AMSU-B • Cross-track scanner • 90 pixels per scan line • Outermost pixels 49° off-nadir • Swath with ≈ 2300 km • Global coverage twice daily • 16 km horizontal resolution (at nadir)

  20. AMSU-B Channels Water vapor Oxygen (Details:John and Buehler,GRL, 31, L21108, doi:10.1029/2004GL021214)

  21. AMSU-B Channels Water vapor Oxygen (Figure by Viju O. John)

  22. AMSU-B Jacobians 20 19 18 19 20 ARTS Simulation, Atmosphere: Midlatitude-Summer (Figure by Viju O. John)

  23. Jacobians depend on Atmospheric State (Figures by Viju O. John) • Measurement not in TTL, but below • Altitude where OLR is very sensitive to H2O changes

  24. AMSU-B Data (Channel 18) Dry areas in the UT (NOAA 16, Channel 18, 15.6.2004. Figure: Oliver Lemke)

  25. Overview • Water vapor in the Earths radiation balance • Operational meteorological microwave satellite instruments (AMSU-B) • AMSU-B measurements of upper tropospheric water vapor • Comparison with radiosonde measurements • Temperature uncertainty and supersaturation • The radiative transfer model ARTS • Summary

  26. Retrieving humidity usually requires a priori, problematic for climate applications • Humidity Assimilation can destroy information on absolute value due to the bias corrections applied (compare lecture by Francois Bouttier) • Solution: Look for a humidity product that is related as closely as possible to the radiances

  27. Regression UTH Retrieval • UTH = Jacobian-weighted relative humidity ≈ mean relative humidity between 500 and 200 hPa • Simple relation: ln(UTH) = a + b Tb • Determine a and b by linear regression with training data set • Details: Buehler and John, JGR, 2004 • Method originally invented by Brian Soden for IR data.

  28. Coefficients independent of training data set • Basically another unit for radiance • Other humidity data must be processed in same way for comparison

  29. AMSU UTH-Climatology (AMSU-B, Channel 18, NOAA 15, Winter 1999-2000. Figure by Mashrab Kuvatov) With deep apologies to Mark Baldwin for the weird color scale...

  30. Walker Circulation during La Nina NOAA 15 AMSU-B UTH DJF 99-00 500-200 hPa HALOE, 82 hPa Gettelman et al, 2001, J. Clim

  31. Comparison with an Infrared Climatology Infrared UTH (1981-1991), Soden and Bretherton, JGR, 101 (D5), 9333-9343, 1996 Microwave UTH (AMSU-B, NOAA 16, 2002), Mashrab Kuvatov

  32. UTH, AMSU-B, Channel 18, NOAA 16, 2002 Difference with and without cloud filter (Figures by Mashrab Kuvatov)

  33. Overview • Water vapor in the Earths radiation balance • Operational meteorological microwave satellite instruments (AMSU-B) • AMSU-B measurements of upper tropospheric water vapor • Comparison with radiosonde measurements • Temperature uncertainty and supersaturation • The radiative transfer model ARTS • Summary

  34. Case Study for one selected Station

  35. (Figure by Viju O. John)

  36. Finding Matches • Define target area (radius 50 km) • Compare mean satellite value to radiosonde • Take standard deviation σ50kmas measure of sampling error

  37. Large variability in σ50km • Lowest values consistent with nominal radiometric noise

  38. Error Model Sources of error: • Radiometric noise of the AMSU measurement • Sampling error due to atmospheric inhomogeneity • Radiosonde measurement error in humidity and temperature • RT model error • AMSU calibration error χ2 tests show that C0 can be taken as a global constant with a value of 0.5K.

  39. Results • Non-unity radiance slope • Possible reasons: • RT model • AMSU • Radiosonde • Increasing radiosonde dry bias under very dry conditions (Buehler et al., JGR, 109, D13103, doi:10.1029/2004JD004605, 2004)

  40. Comparison for a Different Sensor • Kem, Russia (64N, 34E) • Goldbeater’s skin type sondes • very large wet bias (expected from Soden and Lanzante, JGR, 1996 ) (Figure by Viju O. John)

  41. Comparing different Radiosonde Stations • 40 European stations • Sonde data from BADC (John and Buehler, ACP, 2005)

  42. Comparing different Radiosonde Stations (John and Buehler, ACP, 2005) • General dry bias (expected for Vaisala sensor) • Apparently erratic jumps can be understood by sensor and/or procedure changes for individual stations • Information about stations not readily available • Mystery: UK stations have less dry bias, although the are supposed to use similar sensors • See also poster by T. Suortti

  43. Overview • Water vapor in the Earths radiation balance • Operational meteorological microwave satellite instruments (AMSU-B) • AMSU-B measurements of upper tropospheric water vapor • Comparison with radiosonde measurements • Temperature uncertainty and supersaturation • The radiative transfer model ARTS • Summary

  44. Supersaturation in UARS-MLS Data exponential drop-off

  45. Gaussian T distr. Non-Gauss RH distr.

  46. MLS Data Effect of 2K T uncertainty Some of the observed supersaturation can be due to temperature uncertainties (Buehler and Courcoux, GRL, 2003).

  47. Overview • Water vapor in the Earths radiation balance • Operational meteorological microwave satellite instruments (AMSU-B) • AMSU-B measurements of upper tropospheric water vapor • Comparison with radiosonde measurements • Temperature uncertainty and supersaturation • The radiative transfer model ARTS • Summary

  48. RTTOV • Fast RT model • Freely available from Eumetsat NWP SAF • Already configured for most meteorological sensors • Biases compared to more accurate ARTS model (see Poster by Nathalie Courcoux) • Not used for the calculations in this lecture

  49. Public Domain Program, developed together with Chalmers University, Göteborg and University of Edinburgh. Two branches: ARTS-1-0: Clear-sky ARTS-1-1: with cloud scattering

  50. RT Workshop 2004 Radiative Transfer Core Developers (2005) • Development and workshops since 1999. RT Workshop 2005