1 / 17

Abgeleitete Datentypen - 1 -

Abgeleitete Datentypen - 1 -. Aufzählungen. Type Passwort : (Otto, Fritz, Klaus); END_TYPE. Bereichseingrenzungen. Type Sollwert : UINT(100..200); END_TYPE. Diagnose- und Zustandsflags. TYPE Diagnostic_Typ: (DBM, DBC, DAK ):=DBM END_TYPE. PS_Diagnostic. PS_Message.

taipa
Download Presentation

Abgeleitete Datentypen - 1 -

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Abgeleitete Datentypen - 1 - Aufzählungen Type Passwort : (Otto, Fritz, Klaus); END_TYPE Bereichseingrenzungen Type Sollwert : UINT(100..200); END_TYPE

  2. Diagnose- und Zustandsflags TYPE Diagnostic_Typ: (DBM, DBC, DAK ):=DBM END_TYPE PS_Diagnostic PS_Message Diagnostic_Typ BOOL Result Diagnostic Type Result Message Type TYPE Message_Typ: ( ICS, ISA, RTW, REC, DAKE, KOM ):=ICS END_TYPE Message_Typ BOOL Eingansparameter der FB vom Typ Aufzählung Eingansparameter der FB vom Typ Aufzählung

  3. Literale und Konstanten

  4. Remanenz H L T R U N H L T R U N M - R E S E T R U N R U N M - R E S E T ColdstartRetention UINT BOOL Enable Error UINT UINT SetpointStartMarker ActualStartMarker UINT UINT ActualLength SetpointLength Warmstart-Remanenz Kaltstart-Remanenz

  5. Adressierung Analogbaugruppen der PS416 Topologie-Konfiguration Strang Teiln. Slot Typ Index 0 0 2 CPU400 0 0 15 AIO400 : : : : %QAW0.0.15.6 %IAW0.0.15.2

  6. Topologiekonfiguration  AIO-400 Markierte Baugruppe PARAMETRIEREN

  7. Spannungseingänge Wertebereich für Spannungseingänge +/- 10 V, +/- 5 V ohne Mittelwertbildung 5,5 V 5,0 V 2,5 V 11,0 V 10,0 V 5,0 V Wertebereich für Spannungseingänge0...10 V, 0...5 V, 0...1 V ohne Mittelwertbildung 10,5 V 10,0 V 7,50 V 5,00 V 2,50 V 5,25 V 5,00 V 3,75 V 2,50 V 1,25 V 1,05 V 1,00 V 0,75 V 0,50 V 0,25 V 30000 OR 2048 3072 0 1024 2047 OR 30000 -2,5 V -5,0 V -5,5 V -5,0 V -10,0 V -11,0 V OR 0 30000 1024 2048 3072 4095 OR 30000 -0,50 V -0,25 V -0,05 V bipolar unipolar

  8. Stromeingänge OR 2048 3072 4095 OR 30000 DB 1024 2048 3072 4095 OR 30000 820 - 1 mA 1024 31000

  9. Hinweise zur Programmstrukturierung - 1 -

  10. Hinweise zur Programmstrukturierung - 2 -

  11. Programmparametrierung Programmparameter

  12. Transfer (Vergleich) auf die Memory Card =

  13. Anlaufverhalten auf die Memory Card übertragen / ändern

  14. Abgeleitete Datentypen - 2 - Aufzählungen Felder Type Passwort : (Otto, Fritz, Klaus); END_TYPE Type Messwert : ARRAY[1..10] OF INT; END_TYPE Bereichseingrenzungen Type Sollwert : UINT(100..200); END_TYPE

  15. Felder - ARRAY´s . . . :Array[1..10,1..4,1..3] of INT; . . . :Array[1..10,1..4] of INT; 3 DatenFeld:Array[1..10] of INT; 2 1 1 1 1 2 2 2 3 3 3 4 4 4 5 5 5 6 6 6 7 7 7 8 8 8 9 9 9 10 10 10 1 2 3 4 1 2 3 4 DatenFeld[5] DatenFeld[7,4] DatenFeld[5,4,2]

  16. Datenfelder – ARRAY‘s – vierdimensional ?! 4 3 2 1