1 / 15

Analysis of Multi-Turn ERLs for X-ray Sources

Analysis of Multi-Turn ERLs for X-ray Sources. Georg Hoffstaetter Cornell Physics Dept. / CLASSE Progress report on a paper with I. Bazarov, S. Belomestnyk, J. Crittenden, M. Ehrlichman, M. Liepe, C. Mayes, S. Peck, M. Tigner. BBU: Collective Instabilities. Higher Order Modes.

takoda
Download Presentation

Analysis of Multi-Turn ERLs for X-ray Sources

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Analysis of Multi-Turn ERLs for X-ray Sources Georg HoffstaetterCornell Physics Dept. / CLASSEProgress report on a paper withI. Bazarov, S. Belomestnyk, J. Crittenden, M. Ehrlichman, M. Liepe, C. Mayes, S. Peck, M. Tigner

  2. BBU: Collective Instabilities Higher Order Modes

  3. BBU: Collective Instabilities Higher Order Modes

  4. BBU: Collective Instabilities Higher Order Modes

  5. HOM with BBU: Starting from Noise

  6. Optimize shape of cavity (>70 parameter…) to minimize cryogenic losses and maximize limits to beam current Understand sensitivity of optimized design to fabrication errors; find “sloppy” parameter! Main Linac Cavity Optimization Higher-Order-modes Red: Optimized cavity; blue: perturbed cavities

  7. Cavities with misalignments R/Q and Q in cavities with misalignments can be significantly worse then expected, but orders of magnitude. (Here for 1/16mm construction error) A very good safety margin for BBU is therefore needed.

  8. Reason for high sensitivity of HOMs Trapped TTF HOMs: Construction errors in cells change the individual cell’s HOM frequencies and hinder good coupling between cells, leading to trapped modes with much larger Q.

  9. Perturbatio: Baseline Center Cell (minimize cryo-load) and optimized end cells (HOM damping) +-1/16 mm perturbations, 400 cavities

  10. Center Cell (optimized HOM passband widths), optimized end cells (HOM damping) +-1/16 mm perturbations, 400 cavities

  11. Center Cell (optimized HOM passband widths), optimized end cells (HOM damping) +-1/8 mm perturbations, 400 cavities

  12. Improved center cell with increased width passbands Preliminary optimized end-cells, no perturbations, 10 MHz HOM frequency spread One turn BBU Threshold current 1000 simulations

  13. Improved center cell with increased width passbands, and deformations +- 1/16 mm perturbations, no additional HOM frequency spread One turn BBU Threshold current

  14. Detuning from deformations +- 1/16 mm perturbations, no additional HOM frequency spread  1 MHz only!

  15. Need for BBU investigation • Is an ERL test loop needed and why? For BBU studies? • Trapped modes above the beam pipe cutoff are hard to measure without a return loop. Are there beam based measurements without return loop? Excite by beam of 1MHz rep rate as function of x offset to get R/Q*Q. From the width of the resonances one can get Q. • Needs a linac cryomodule with beam, possibly a shortened model. • Important to measure Q of HOMs in vertical test as quality test. • Study is needed on keeping production tolerances. • Conclusion: BBU effects are well understood and mitigations have been well understood in experiments with existing return loops.

More Related