1 / 1

Abstract

Application of OMI Ozone Profiles in CMAQ. M. Newchurch 1 , L. Wang 1 , A. Biazar 1 , M. Khan 2 , X. Liu 3,4 , D. Byun 5 , B. Pierce 6 1 UAH, 2 USRA, 3 SAO, 4 NASA/UMBC-GEST, 5 UH, 6 UW. Abstract

tanek
Download Presentation

Abstract

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Application of OMI Ozone Profiles in CMAQ M. Newchurch1, L. Wang1, A. Biazar1, M. Khan2, X. Liu3,4, D. Byun5, B. Pierce6 1UAH, 2USRA, 3SAO, 4NASA/UMBC-GEST, 5UH, 6UW Abstract Using OMI ozone profiles as the boundary conditions for CMAQ calculations significantly improves the agreement of the model with ozonesonde observations during IONS06. This improvement results from both representing the free-tropospheric ozone amounts more accurately and also from representing recirculating air masses more accurately. A simultaneous assessment of the OMI ozone profiles directly with the sondes indicates agreement to better than 10% throughout the free troposphere with 10-20% differences in the PBL. Model Evaluations cntrl raqms_bc sat_bc sat_icbc Using OMI boundary (bc) or bc+initial conditions, results in significantly better agreement between CMAQ and the sondes in the middle and upper troposphere (Figure 3). The temporal evolution seen at Huntsville is also significantly improved throughout the troposphere by using OMI ic/bc information (Figure 4). The monthly mean difference over 252 sonde stations likewise shows the vertical profile of the improvement in CMAQ with increasing amounts of OMI ozone information, including the direct comparison of OMI ozone profiles and ozonesondes in CMAQ space (Figure 5). 212 mb (level 33; ~11584 m) 501 mb (level 24; ~5352 m) Experiment Description In this study, 4 CMAQ runs are made: (1) cntrl: uses static profiles as the lateral boundary conditions; (2) raqms_bc: obtains lateral boundary conditions from global chemical model output (RAQMS); (3) sat_bc: uses OMI/O3 as lateral boundary conditions; (4) sat_icbc: uses OMI/O3 as lateral boundary conditions, and once a model-day, modifies simulated O3 with OMI O3. 853 mb (level 15; ~867 m) Fig 3. O3 (ppbv) 1900 UTC, 8/21/2006 simulated by 4 CMAQ runs; over plotted with 9 ozonesondes found within 1500~2300 UTC. OMI/O3 Data Processing cntrl raqms_bc sat_bc sat_icbc • Ozone Monitoring Instrument (OMI) onboard NASA’s AURA satellite provides mapping of O3 profiles at a nominal ground footprint of 13x48 km2 at nadir. • OMI O3 profiles during each day are gridded to CMAQ domain (36km x 36km resolution) using a “drop-in-the-box” method. • Interpolate gridded OMI O3 profiles (24 layers) onto 39 sigma layers of CMAQ. Fig. 1 OMI O3 retrievals between 1013-701mb during Aug. 21, 2006, are gridded to CMAQ horizontal domain. Fig 5. Differences calculated between model simulated O3(ppbv) and ozonesondes, as well as between level-2 OMI/O3 profiles and ozonesondes, during August 2006. Sample size too small (0~50) Evaluation with IONS06 ozonesondes Fig 4. CMAQ simulated ozone variations at Huntsville, AL, during August 2006. Ozonesonde measurements are re-sampled onto CMAQ vertical resolution and over-plotted. Mean of (x-sonde)/sonde (%) Sample size = 252 (varies with altitude) • IONS06 provides the best set of free tropospheric ozone measurements ever gathered across the continent in a single season data. • Of the IONS06 ozonesondes, 252 are chosen for evaluation of CMAQ results. Criteria include: • Within CMAQ domain; • Launched during UTC1500 ~ 2300, Aug 2006. Contact info: Mike Newchurch mike@nsstc.uah.edu The 90th American Meteorological Society Annual Meeting, 17-21 January 2010 - Atlanta, GA Conclusions Using OMI ozone profiles as lateral BCs for CMAQ, improves the middle and upper-tropospheric ozone calculations. By modifying modeled O3 with OMI O3 throughout model domain once a model-day, further improvement can be made, especially in interior region. Fig. 2 IONS06 Ozonesonde network. (http://croc.gsfc.nasa.gov/intexb/ions06.html).

More Related