An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Refined Scientific Requirementsfor the PTCS Jim Condon

  2. GBT Science Summary – Frequency Coverage

  3. Tracking errors: sensitivity loss and flux uncertainty

  4. Distributions of flux uncertainties from tracking errors

  5. Pointing requirements • 2003 October: • improved blind pointing • usable pointing at 52 GHz σ = 2.8 arcsec • Early 2005: • good pointing at 52 GHz σ = 2.0 arcsec • usable pointing at 86 GHz σ = 1.7 arcsec • 2005 October: • good pointing at 86 GHz σ = 1.2 arcsec • usable pointing at 115 GHz σ = 1.3 arcsec

  6. GBT pointing calibrators NVSS calibration sources 45 arcsec resolution σ = 0.7 arcsec σ²(cal) < σ² / 16 at 52 GHz New calibration images 5—10 arcsec resolution σ< 0.3 arcsec σ²(cal) < σ² / 16 at 115 GHz

  7. Sky distribution of GBT pointing calibrators

  8. Tracking time • Operational efficiency = (1 – β) • Calibration overhead β = 0.2, t(cal) = 5 min • Required tracking time Δt = t(cal) / β ≈ 0.5 hours • We may be able to reduce Δt or • increase operational efficiency by reducing β, • but Δt < 12 min (3 deg at sidereal rate) not useful

  9. Wind and short-term (40 s) pointing changes σ(wind) = 1"[ v / 2.5 m/s ]²

  10. GBT cumulative wind-speed distribution Extreme wind Normal wind Benign wind

  11. Wind speed conditions • Operational efficiencies: • benign conditions (2.5 m/s): 60% • normal conditions (3.5 m/s): 75% • extreme conditions (5.0 m/s): 90%

  12. Wind speed requirements • σ²(wind) = σ² / 4 (1/4 of variance allocated to wind) • 2003 December results: • usable 52 GHz pointing at v = 3.0 m/s • Early 2005 requirements: • usable 52 GHz pointing at v = 3.5 m/s • usable 86 GHz pointing at v = 2.5 m/s • 2005 October requirements: • good 86 GHz pointing at v = 2.5 m/s • usable 115 GHz pointing at v = 2.5 m/s

  13. Thermal requirements • As with wind, the main scientific requirement is • good operational efficiency. • Thermal corrections can be made continuously. • Thermal stresses may be too large for good pointing • around sunrise and sunset • while slewing around the sky on a sunny day

  14. Blind pointing • Calibrator acquisition: • σ(az) = 0.30 θ for 90% reliability on first try • 2003 October: • 52 GHz requirement σ(az) = 4.3 arcsec • Early 2005: • 86 GHz requirement σ(az) = 2.6 arcsec • 2005 October: • 115 GHz requirement σ(az) = 1.9 arcsec

  15. Blind pointing gradients |ΔE| / rad

  16. Requirements for blind pointing gradients • 2003 December results: • good pointing at 52 GHz |ΔE| = 10.8 arcsec/rad • Early 2005: • usable pointing at 86 GHz |ΔE| = 9.4 arcsec/rad • 2005 October: • good pointing at 86 GHz |ΔE| = 6.5 arcsec/rad • usable pointing at 115 GHz |ΔE| = 7.0 arcsec/rad

  17. Aperture surface accuracy • good efficiency ε = λ / 16 η = 0.54 • usable efficiency ε = λ / 4πη = 0.37 • 2003 October: • usable efficiency at 52 GHz ε = 0.46 mm • Early 2005: • usable efficiency at 86 GHz ε = 0.28 mm 2005 October: • good efficiency at 86 GHz ε = 0.22 mm • usable efficiency at 115 GHz ε = 0.21 mm

  18. Focus tracking stability

  19. Focus tracking requirements • Good focusing Δy = | λ / 4 | • Usable focusing Δy = | λ / 2 | • 2003 October: • usable focusing at 52 GHz Δy = 2.9 mm • Early 2005: • usable focusing at 86 GHz Δy = 1.7 mm • 2005 October: • good focusing at 86 GHz Δy = 0.9 mm • usable focusing at 115 GHz Δy = 1.3 mm

  20. Summary of PTCS requirements: • 2003 October: • usable pointing at 52 GHz σ = 2.8 arcsec • improved blind pointing • calibrators OK for 52 GHZ σ(cal) = 0.7 arcsec • tracking time at 52 GHz Δt = 0.5 hours • 60% of time (benign wind) v = 2.5 m/s • blind pointing at 52 GHz σ(az) = 4.3 arcsec • blind gradient at 52 GHz |ΔE| = 10.8 arcsec/rad • usable efficiency at 52 GHz ε = 0.46 mm • usable focusing at 52 GHz Δy = 2.9 mm

  21. Summary of PTCS requirements: • Early 2005: • usable pointing at 86 GHz σ = 1.7 arcsec • calibrators OK for 86 GHz σ(cal) = 0.3 arcsec • tracking time at 86 GHz Δt = 0.5 hours • 60% of time at 86 GHz (benign wind) v = 2.5 m/s • 75% of time at 52 GHz (moderate wind) v = 3.5 m/s • blind pointing at 86 GHz σ(az) = 2.6 arcsec • blind gradient at 86 GHz |ΔE| = 9.4 arcsec/rad • usable efficiency at 115 GHz ε = 0.28 mm • usable focusing at 86 GHz Δy = 1.7 mm

  22. Summary of PTCS requirements: • 2005 October: • good pointing at 86 GHz σ = 1.2 arcsec • calibrators OK for 115 GHz σ(cal) = 0.3 arcsec • tracking time at 115 GHz Δt = 0.5 hours • 60% of time at 115 GHz (benign wind) v = 2.5 m/s • 75% of time at 52 GHz (moderate wind) v = 3.5 m/s • blind pointing at 115 GHz σ(az) = 1.9 arcsec • blind gradient at 86 GHz |ΔE| = 6.5 arcsec/rad • usable efficiency at 115 GHz ε = 0.21 mm • good focusing at 86 GHz y = 0.9 mm