110 likes | 258 Views
Design Solution. For a 35kW level II enclosure: 11 pieces are to be cut from received board Installed into walls/doors Installed above generator and around exhaust system. Insulation board dimensions. Cutting/Forming. Done with circular saws 57.5 feet of cutting per enclosure
E N D
Design Solution For a 35kW level II enclosure: • 11 pieces are to be cut from received board • Installed into walls/doors • Installed above generator and around exhaust system
Cutting/Forming Done with circular saws 57.5 feet of cutting per enclosure Ventilation is required to eliminate spread of dust
Exhaust box installation Insulation block Small bolts Perforated steel
Thickness will remain the same Thermal conductivity of expanded perlite: .85 Btu in/hr ft2 °F Thermal conductivity of mineral wool: 1.06 Btu in/hr ft2 °F Same thickness will be used Thermal insulation will improve
Thermal conductivity heat flow rate thickness *Assuming a heat flow of 3000 Btu/hr area thermal conductivity ∆T = 735 °F • For mineral wool with k = 1.06 Btu in/hr ft2°F • ∆T = 590 °F
Further Testing • Acoustical testing • Mock-up enclosure • Mechanical testing • Ability for material to withstand vibrations • Impact testing