1 / 34

The Majorana Experiment

The Majorana Experiment. Ryan Martin for the LBNL Majorana Group NSD Monday Morning Meeting 26 April 2010. Outline. Neutrinoless double-beta decay The use of 1 tonne of Germanium The Majorana Demonstrator Technology Developments at LBNL. 2 . 0 . 10 4 0 .

tekla
Download Presentation

The Majorana Experiment

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The Majorana Experiment Ryan Martin for the LBNL Majorana Group NSD Monday Morning Meeting 26 April 2010

  2. Outline • Neutrinoless double-beta decay • The use of 1 tonne of Germanium • The Majorana Demonstrator • Technology Developments at LBNL Ryan Martin, LBNL, MMM, 4/26/2010

  3. 2 0 104 0 Neutrinoless Double-Beta Decay Isotope Q % • Neutrinoless double beta decay is a very rare process that can occur in isotopes where beta-decay is energetically forbidden • Observing this requires excellent energy resolution Ryan Martin, LBNL, MMM, 4/26/2010 G. Gratta

  4. disfavored by 0 Klapdor-Kleingrothaus et al. claimed signal Tonne Scale Disfavored by cosmology Experimental Searches for 0nbb Klapdor-Kleingrothaus’ 6.4s claim (Mod. Phys. Lett. A 21, 1547 (2006) Phase Space Nuclear Matrix Element T½0ν=( G0ν|M0ν|2〈mββ〉2 )-1 〈mββ〉 ≡ Ue12m1+ Ue22m2eif2 + Ue32m3eif3 PMNS Matrix Majorana Phases • The half life for 2nbb is of order 1020 years, so 0nbb is very rare if it exists • A tonne scale experiment is required to probe mbb of order the atmospheric mass-squared difference Ryan Martin, LBNL, MMM, 4/26/2010

  5. Impact of detecting 0nbb • Only practical way to see if neutrinos are Majorana particles • Sets the scale for neutrino masses • Allows for leptogenesis as a way to solve the matter/anti-matter asymmetry in the Universe Ryan Martin, LBNL, MMM, 4/26/2010

  6. Arguments for using Germanium • There are several reasons for using Germanium diode detectors (HPGe): • Source is detector • Can be enriched in 76Ge to 86% • Low level of radio-impurities • Technology is well understood • Energy resolution is excellent (~0.2% at 2039keV) • Easy to operate (LN temperature, volume is small) Ryan Martin, LBNL, MMM, 4/26/2010

  7. Towards a 1Tonne Experiment • In order to build a 1 tonne Ge experiment, one must demonstrate that the required background levels can be achieved with a technology that can scale • The Majorana and GERDA collaborations are both working to demonstrate different technologies to reduce and remove radioactive backgrounds in Ge detector arrays • There is a cooperative agreement between the two collaborations to share information and come together to build an international 1 tonne Ge experiment that uses the best features from the two technologies Ryan Martin, LBNL, MMM, 4/26/2010

  8. Challenges in detecting 0nbb • The main challenges in detecting 0nbb are backgrounds, backgrounds and backgrounds • One aims to have backgrounds of the level of 1 count per tonne per year within a 4keV Region Of Interest (ROI) around 2039keV to be sensitive to the atmospheric mass scale • Need to enrich Ge to have significant quantities of 76Ge Ryan Martin, LBNL, MMM, 4/26/2010

  9. Main backgrounds • Natural radioactivity in detector components (U, Th) • Surface contaminants (a, b) • Low-energy backgrounds (Ge isotopes, 65Zn, 73As,3H; low-E compton from K, U, Th; 210Pb brem; …) • Cosmogenic radioactivity (68Ge, 60Co) • Muons, fast neutrons • 2nbb decay • Neutrino scattering (reactor, solar, atm., geo, SN…) Use clean materials Go deep underground Not much you can do! Ryan Martin, LBNL, MMM, 4/26/2010

  10. LN Dewar Pb/Cu Shield Cu Cryostat 2m Lift The Majorana Demonstrator • The Majorana experiment is a US-led effort that will be deployed at the Sanford lab in South Dakota • The design focuses on the use of high purity material and will use a Pb/Cu shield • The experiment will be run in phases and will culminate with the use of 60 kg of Ge (30kg of which will be enriched) Ryan Martin, LBNL, MMM, 4/26/2010

  11. Technologies used in Majorana • Electroformed copper • Low-noise electronics and DAQ • Stringent materials assays • Point contact Ge detectors tests • Low background detector mounts • Monte Carlo simulations • Various analysis techniques LBNL strongly involved! Ryan Martin, LBNL, MMM, 4/26/2010

  12. Electroformed copper • The use of electroformed copper removes impurities and significantly reduces backgrounds; goal is 0.3 µBq 232Th and 238U/kg Cu (~0.08 x 10-12 g/gCu) • The copper is electroformed on steel mandrels that have the same diameter as the cryostats • A total of 16 baths will be deployed underground. The material from the electroformed cylinders will be machined into various components Ryan Martin, LBNL, MMM, 4/26/2010

  13. Low Noise Electronics Copper “mount” for the board FET Amorphous Ge resistor Fused-silica board Au/Cr pads FET Parylene cable • Paul Luke has developed a “low mass front end” (LMFE) board that allows one to have an amplification stage close to the Ge diode and thus reduce the noise in the signal from capacitance • The resistive feedback configuration for this pre-amplier is achieved by using amorphous Germanium and the intrinsic capacitance between the pads. The large resistor also reduces noise in the signal, allowing for a low threshold • Our group is testing and characterizing various implementations for this design Ryan Martin, LBNL, MMM, 4/26/2010

  14. Electronics Development • LBNL is playing a leading role in the development of the electronics for the Majorana Demonstrator: • LMFE board • Cable Characterization • Preamplifier design • Digitizer Card Characterization (Gretina and Struck cards) • Low noise power source Ryan Martin, LBNL, MMM, 4/26/2010

  15. Materials Assays • In order to determine which materials are suitable to go into the experiment, one needs to be able to assay the radio purity of materials - Several techniques and facilities are being used by the collaboration: • Gamma counting • Accurate but slow and needs large samples ~ 50-100ppt U,Th at Oroville • Can determine activity from all parts of a decay chain and unexpected contaminants • Neutron Activation Analysis • Accurate and can use small samples • Can determine activity from all parts of a decay chain and unexpected contaminants • ICP-MS (Inductively coupled plasma mass spectroscopy) • accurate and can (must!) do small samples ~ <1ppt U, Th at PNNL • Can only determine contributions from top parts of decay chain • LBNL is responsible for the assay and characterization of the components for the low mass front end board Ryan Martin, LBNL, MMM, 4/26/2010

  16. Point contact Ge detector Point contact Ge detector allow multi-site events to be identified- invented by Paul Luke (LBNL) coax Ge PC Ge Ryan Martin, LBNL, MMM, 4/26/2010

  17. Pulse Shape Analysis • The use of point contact detectors allows one to use pulse shape analysis to distinguish Multi-Site Events (MSE, background-like) from Single Site Events (SSE, signal-like) 232Th source data Red: all events Blue: PSA-selected events 208Tl DEP 9/30/09 Radford, RedTeam Review Ryan Martin, LBNL, MMM, 4/26/2010

  18. Segmented PPC Prototype – SPPC Segment waveform Point-contact waveform LDRD (Amman, Luke, Chan, Lesko) • Combination of point contact and segment detector • Idea is to read out both electrodes to determine the position of the events Ryan Martin, LBNL, MMM, 4/26/2010

  19. Mini-PPC Detector To cold finger Pin contact Contact pressure adjust Crystal mount Temp Ref plate • The main purpose of the mini PPC was to study surface passivation in a conventional setup (shown here) • The detector was also to used to study the low mass front end board (different configuration, not shown) as well as help to characterize the digitizing boards To sensor/heater IR shield base-plate Ryan Martin, LBNL, MMM, 4/26/2010

  20. Low Background Detector Mounts my watch Front end board Detector “blank” Cold plate Cryostat “Mercedes” mount PTFE blocks to support crystal • The Majorana experiment will employ detector mounts fabricated from electroformed copper in order to reduce backgrounds • These are being tested at LBNL Ryan Martin, LBNL, MMM, 4/26/2010

  21. Detector Simulation • The Majorana and GERDA collaborations have worked on the MaGe Monte Carlo simulation package (using Geant4 and ROOT) • O(5) publications • Pulse shape calculations also implemented • Simulation and Analysis task lead is at LBNL Example: 60Co in cryostat granularity PPC PSA Ryan Martin, LBNL, MMM, 4/26/2010

  22. Pulse Shape Simulation • LBNL group has done work on modelling the electric field to determine pulse shapes • BEGe detector from Canberra shown here Geometry of BEGe simulated pulses Electric field and potential Point contact Ryan Martin, LBNL, MMM, 4/26/2010

  23. Digital Energy Filter Development Filter Pulse • New energy digital filter was developed to correct for possible changes in the response of the front end electronics (varying pole zero correction) and improve the energy resolution • Individual pulses are fit to determine the pole zero correction and the energy Ryan Martin, LBNL, MMM, 4/26/2010

  24. Discreet Wavelet Analysis Can be used to tag SSE and MSE Can be used for de-noising • The Discreet Wavelet Transform (DWT) is a reversible transformation (like the Fourier Transform) that can be done on a discreetly sampled signal • Unlike the Fourier Transform, the DWT contains information about the frequencies contained in a signal and when they occur Ryan Martin, LBNL, MMM, 4/26/2010

  25. Majorana Sensitivity The Majorana experiment will be able to test the Klapdor claim Ryan Martin, LBNL, MMM, 4/26/2010

  26. Low noise electronics and DM search • Low capacitance results in very good resolution and low noise • Can look for low energy events (Dark Matter searches) The CoGeNT collaboration, has recently published a paper showing the energy spectrum in a low-threshold point contact Ge detector (http://arxiv.org/abs/1002.4) 2 CDMS Events DAMA/LIBRA Ryan Martin, LBNL, MMM, 4/26/2010

  27. Summary • 0nbb discovery would be a very compelling result • 1 tonne of Ge would allow one to explore mass scales beyond the inverted mass hierarchy • The Majorana Demonstrator will soon start to evaluate the feasibility of a tonne scale 76Ge experiment as well as test the Klapdor claim • LBNL is leading the detector development and analysis tasks for the Majorana Demonstrator and will continue to play a leadership role in the experiment Ryan Martin, LBNL, MMM, 4/26/2010

  28. Backup Slides Ryan Martin, LBNL, MMM, 4/26/2010

  29. http://ilias.in2p3.fr/ilias_site/meetings/documents/ILIAS_3rd_Annual_Meeting/Parallel_DBD_Exp_Zuzel.pdfhttp://ilias.in2p3.fr/ilias_site/meetings/documents/ILIAS_3rd_Annual_Meeting/Parallel_DBD_Exp_Zuzel.pdf The GERDA Exeperiment • The GERDA experiment is a European experiment that is in the final phases of construction at LNGS • The Ge diodes are immersed in LAr inside a stainless steel tank, surrounded by an instrumented tank of water • The first phase of the experiment uses ~18kg of enriched Ge from the IGEX and Heidelberg Moscow experiments - in the second phase, they will have a total of 35-40kg of enriched Ge Ryan Martin, LBNL, MMM, 4/26/2010

  30. Towards a 1 tonne Ge experiment Sensitivity depends on energy resolution, background rate and exposure: energy resolution background rate live-time active mass A 1 tonne experiment is well suited for exploring mass scales down to the atmospheric neutrino oscillation mass-squared difference. Ryan Martin, LBNL, MMM, 4/26/2010

  31. 3 2 mass mass 1 2 1 3 Neutrino Mass • We know from neutrino oscillation experiments that neutrinos have mass, but: • We do not know the hierarchy • We do not know the absolute mass scale • We do not know if the neutrinos have a Majorana mass term (the only particle that could) ? (solar, reactor) (atmospheric, LBL) ? ? Ryan Martin, LBNL, MMM, 4/26/2010 Normal hierarchy ? Inverted hierarchy ?

  32. Other Experiments Ryan Martin, LBNL, MMM, 4/26/2010

  33. Nuclear Matrix Elements Ryan Martin, LBNL, MMM, 4/26/2010

  34. The Majorana and Advanced Detector Development at LBNL • Staff Scientists: Alan Poon, Yuen-Dat Chan, Brian Fujikawa, Kai Vetter • Engineers: Paul Luke, Harold Yaver, Sergio Zimmerman • Postdocs: Jason Detwiler, James Loach, Jing Qian, Ryan Martin • Undergraduate Student: Justin Tang • Summer Students through mentoring program Ryan Martin, LBNL, MMM, 4/26/2010

More Related