Trigger Board Mini-Workshop Fermilab, 1 North April 10, 2003 Trigger Menu for Luminosity 60-80E30

Trigger Board Mini-Workshop Fermilab, 1 North April 10, 2003 Trigger Menu for Luminosity 60-80E30 http://wwwd0.fnal.gov/RunIIaOperations/TriggerBoard/d0_private/workshop_10apr03/tb_wk_page.html. Ground Rules Target Luminosity 60E30 but also quote trigger rates at 80E30

thad
Download Presentation

Trigger Board Mini-Workshop Fermilab, 1 North April 10, 2003 Trigger Menu for Luminosity 60-80E30

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Trigger Board Mini-Workshop Fermilab, 1 North April 10, 2003 Trigger Menu for Luminosity 60-80E30 http://wwwd0.fnal.gov/RunIIaOperations/TriggerBoard/d0_private/workshop_10apr03/tb_wk_page.html • Ground Rules • Target Luminosity 60E30 but also quote trigger rates at 80E30 • Design for DAQ rates L1/L2/L3 = 1200/600/50 Hz • Level-3 will be running p15, which has some new filter capabilities • Design your triggers for calorimeter eta coverage up to 3.2.  • Monitor triggers should be requested and justified in association with the proposed physics triggers • All trigger requests should be accompanied with efficiency vs rate plots extracted from data • Rate estimates of proposed triggers should take into account overlap effects from similar type triggers

  2. JT_95TT CJT(4,5) L2JET(1,30) L3JET(1,95) 40E30 L1=52 Hz L2= 39 Hz L3=0.22 Recent L2 change increased L2rej from 1.06 to 1.33 Expansion to ||<3.2 increased L1 from 44 to 52 Hz but did not increase rate to tape* 60E30 L2=59 Hz 80E30 L2=78 Hz CJT(3,5) L1=156 Hz, L2=? *In general L1 increased by 20%, but L3 by 0-10% for all QCD triggers, must understand

  3. JT_125TT CJT(4,7) L3JET(1,125) 40E30 L1=11Hz L2= 11 Hz L3=0.04 CJT(7) may disappear. Could change to CJT(3,5), would need L2JET to control L2 rate.

  4. QCD Special Run-Low ET Studied new minbias+L3 jet monitor triggers Note the minbias rate is 270x the CJT(5) rate, but the L3 rate is 7x the JT_8TT rate, so if we replaced the JT_8TT trigger of .15 Hz (.22 at L1/L2), we would add about 40x More L2 (9 Hz) to keep the same L3. CJT(2,3) L3JET(1,15) has ~same L1 rate as JT_8TT, but 4x lower L3 rate, so could get 4x stats with same or better turn-on

  5. QCD Special Run-Gap CJT(2,5) L3JET(1,25) GAPN 40E30 pre=2 L1=3 L2=3 L3=0.6 L3(35) gives x2.5 rejection ; L3(45) gives x5 rejection allows addition of CJT(2,3) L3JET(1,15) x9 higher L1 x4 higher L3 (than 25 trigger) 40E30 CJT(2,3) L3JET(1,15) Pre=12 L1/L2=5 L3=0.4 CJT(2,5) L3JET(1,45) Pre=1 L1/L2=6 L3=0.24 60E30 CJT(2,5) L3JET(1,45) Pre=1 L1/L2=9 L3=0.36

  6. Summary Need L2 studies on CJT(3,5) trigger for setting thresholds for JT_TT95 and JT_TT125 Need link to turn-on studies Change current gap triggers from 25 to 45, add low ET gap triggers FPD triggers still in future