1 / 9

Chromaticity during injection

CERN, FiDeL meeting, 15 th February 2011. Chromaticity during injection. Nicholas Aquilina TE-MSC-MDA Acknowledgements : E. Todesco, W. Venturini, EIC and operators. Contents. Measurements of chromaticity during injection

theta
Download Presentation

Chromaticity during injection

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. CERN, FiDeL meeting, 15th February 2011 Chromaticity during injection Nicholas Aquilina TE-MSC-MDA Acknowledgements: E. Todesco, W. Venturini, EIC and operators

  2. Contents • Measurements of chromaticity during injection • Post-processing of data in order to get the bare chromaticity of the machine removing the chromaticity trims • Fitting of the data with FiDeLparametrization • Proposal for the average correction

  3. Measurements and trims • The value of the chromaticity is obtained from the logbook (as done by [W. Venturini]) • Unfortunately there is no chromaticity measurement during injection in TIMBER • The trims can be obtained: • from the logbook • from TIMBER; currents in MCSF/MCSD

  4. Chromaticity decay • Chromaticity decay as obtained by W. Venturini • Note the two different families of decay • In this case the trims were being obtained from the logbook Horizontal chromaticity versus time at injection, beam1 (blue), beam2 (red) [W. VenturiniDelsolaro]

  5. Chromaticity decay • The chromaticity measurement was taken from the logbook without taking note of the trims • Instead the trims were obtained from TIMBER • The bare chromaticity of the machine was then obtained by adding the trims to the measurements • Note how the data converged to one plot

  6. Fitting of the data • A double exponential1 of this form was used to model this decay • This model fits very well the chromaticity decay 1 N. Sammut, L. Bottura, and J. Micallef. Phys. Rev. ST Accel. Beams 9, 012402 (2006)

  7. Fitting of the data where Q’h* and Q’v* are the starting bare chromaticity values as dictated by the machine optics

  8. Average correction • Based on the fits shown in the previous slide the following corrections are suggested: suggested values • 1 taking 1 unit of b3 = 40 units of Q’ • 2 N. Sammut, L. Bottura, and J. Micallef. Phys. Rev. ST Accel. Beams 10, 082802 (2007) for a 50A/s ramp rate and IFT = 12kA • 3 parameters in FiDeL database since 2008, for a 10A/s ramp rate and IFT = 12kA, in fact c = 0.5 was used instead (since IFT = 6kA)

  9. Conclusions • Chromaticity measurements during injection can be used to understand better the b3 decay behaviour • From this analysis it can be seen that the b3 decay is a factor of 5 slower than the expected value from the measurements done at SM18, however the decay amplitude is in line with these measurements • Injecting the beam as soon as possible once at injection will help to get a better model of the chromaticity during the first moments of the decay • Having more measurements of the chromaticity both during injection and ramping logged in TIMBER will be very helpful for further analysis

More Related