1 / 10

First results of irradiations of silicon pad sensors at KRI

First results of irradiations of silicon pad sensors at KRI. Dmitry Karmanov Institute of Nuclear Physics Moscow State University. 3rd Work Meeting of the CBM-MPD STS Consortium. Objects. 9 structures from CiS: Size 7 x 7 mm 2 , Active area 5 х 5 mm 2 , Thickness - 280 mkm

thor
Download Presentation

First results of irradiations of silicon pad sensors at KRI

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. First results of irradiations of silicon pad sensors at KRI Dmitry Karmanov Institute of Nuclear Physics Moscow State University 3rd Work Meeting of the CBM-MPD STS Consortium

  2. Objects • 9 structures from CiS: • Size 7 x 7 mm2, • Active area 5х5 mm2, • Thickness - 280 mkm • 6 structures from ELMA: • Size - 10 x 10 mm2, • Active area ~8 x 8 mm2, • Thickness 300 mkm 3rd Work Meeting of the CBM-MPD STS Consortium

  3. Doses CiS: • 7.3х1010n/сm2, • 7.3х1011n/сm2, • 1.6х1012n/сm2, • 1.0х1013n/сm2, • 1.8х1013n/сm2, • 6.4х1013n/сm2 • MSU: • 1.5х1012n/сm2, • 1.2х1013n/сm2, • 2.1х1013n/сm2 3rd Work Meeting of the CBM-MPD STS Consortium

  4. Annealing Two kinds of annealing: • 60 minutes at 20oC • 60 minutes at 60oC All other time samples kept cold 3rd Work Meeting of the CBM-MPD STS Consortium

  5. ~+20C 0 + 60мин. +60C 0 + 80мин. Base plot (RD48) 3rd Work Meeting of the CBM-MPD STS Consortium

  6. 3rd Work Meeting of the CBM-MPD STS Consortium

  7. Results (1) 3rd Work Meeting of the CBM-MPD STS Consortium

  8. Results (2) 3rd Work Meeting of the CBM-MPD STS Consortium

  9. Full Depletion Voltage 3rd Work Meeting of the CBM-MPD STS Consortium

  10. Summary • Good agreement with known data on current degradation for high doses . • Not so good for low doses, but might be it because of mistakes in dose measurements. • Expected behavior for full depletion voltage • We are almost ready for real work!!! 3rd Work Meeting of the CBM-MPD STS Consortium

More Related