An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Session 4 – Unusual Applications, SOP, etc. Mercury Speciation Workshop 330 Nantucket Blvd. Toronto, Canada M1P 2P4 Rev 1.00 Aug 2002

  2. Issues in Session Four 1 Unusual Applications? 2 Towards an SOP 3 Any other items

  3. Unusual Applications

  4. Dynamic Dilution for Source Assessment • This is slightly different than a conventional mercury CEM • Furthers work conducted by Prestbo using static dilution chamber • Allows some of the reactions that occur in ambient air to be seen • May provide a better indication of: • What enters the ecosystem • Rather than what does up the stack

  5. Towards an SOP

  6. Why an SOP ? • Allow inter-comparability of automated 1130/35 data taken anywhere

  7. Items in an SOP? • Where to take the measurement • High vertical gradients observed • Height above grade is important • Minimize building plume effects • Must be tempered by reality: • Must access the outdoor components

  8. Items in an SOP • Standardized instrument conditions • Sample time & flow rate • Desorption times and temperatures • Maintenance interval for denuder & RPF • Filter, impactor cleaning/change interval • Data processing conventions • QA/QC procedures • Procedures for instrument validation • Validate entire sample path • Calibrate MFMs, etc

  9. Items in an SOP • Calibration procedures • Requires a field portable source to be developed first!

  10. Any Other Items ?

  11. End of Session 4