1. MX/MF MOISTURE ANALYZERS
3. DESIGN FEATURES Super Hybrid Sensor Technology
RS232 Interface
Easy to Read VFD
Quick Reference Operation Guide
Automatic Self-Checking Function
Clearly Marked Operation Panel
Front Spirit Level
400W Halogen Lamp
Easy and low cost to replace
5000 hrs. rating
Fast Heating 50-200C in < 2minutes
4. SUPER HYBRID SENSOR (SHS) MFR-High Resolution
Extremely Fast
Less sensitive to temperature than previous MFR cells
Small and compact
Less expensive to produce than older MFR
Durable
5. Easy Maintenance
Removable Heater Cover
6. Low Cost Replacement Lamp
7. STANDARD ACCESSORIES Reusable Sample Pans (20)
Pan Handles (2)
Tweezers
Spoons
Test Standard (Sodium Tartrate Dihydrate-30 g)
Display Cover
Dust Cover
Data Cable (MX-50 only)
9. Easy to Use
Operation Instruction Card
10. OPERATIONAL FEATURES Four Measurement Programs
Standard
Automatic
Timer
Manual
Program Memory
MX-50 20 sets
MF-50 10 sets
Four Measurement Modes
Wet Base
Dry Base
Solid content
Ratio Results Memory
MX-50 100 results
MF-50 50 results
GLP/GMP/ISO Conformity Software
Communication Software
Win-CT Moisture Standard with MX-50
Win-CT Standard with MF-50 (Win-CT Moisture optional)
11. OPERATIONSTANDARD MODE Operator sets accuracy, HI, MID, or LO, (see accuracy parameters on next slide.
Operator sets temperature, and moisture measurement unit.
Analyzer determines sample weight necessary based on accuracy required.
Auto stop at %/minute programmed.
12. STANDARD MODE ACCURACY SETTINGS
13. Auto Stop Mode Operator Sets:
Temperature,
% of Change,
Moisture Type &
Weight Resolution.
Auto Stop Occurs at %/min. Setting.
14. Accuracy Settings for AUTO Mode Setting
0.005% / min.
0.01% / min.
0.02% / min.
0.05% / min.
0.1% / min.
0.2% / min.
0.5% / min.
1.0% / min.
2.0% / min.
MX-50 MF-50
? -
? -
? ?
? ?
? ?
? ?
? ?
? ?
? ?
15. TIMER Mode Operator Sets:
Temperature (between 50 ?C to 200 ?C),
Timer (between 1 480 Minutes),
Moisture Type &
Weight Resolution.
Test Auto Completed when Timer Expires
16. MANUAL MODE Operator Sets:
Temperature
Moisture Type &
Weight Resolution.
Measurement is Stopped Manually at Any Time.
17. WinCT-Moisture SOFTWARE Windows software for MX-50
Optional for MF-50
Shows Drying Curve on the Display
Determines The Best Temperature for Moisture Measurement
20. OTSOptimal Temperature Setting Allow the Moisture Analyzer to determine the best test temperature and heating time.
22. PERFORMANCE vs. COMPETITION
23. PRICING vs. COMPETITION
26. NEW A&D MX/MF MOISTURE ANALYSER - SUMMARY Perform better than competitors
Easier to use and set-up than competition
Modern, updated design and styling
Durable, reliable, and cost less to maintain
Priced significantly lower than competition
Which represents