EASY - Ein intelligentes Steuerrelais ( MK-A010 )

Herzlich Willkommen zu Ihrem Seminar:. EASY - Ein intelligentes Steuerrelais ( MK-A010 ). EASY600. EASY412. Typenschlüssel - EASY. Steuerrelais - EASY. mm 2 = 35,5 mm 4 = 71,5 mm 6/8 = 107,5 mm. = Display X = Display. C = Clock

tommy
Download Presentation

EASY - Ein intelligentes Steuerrelais ( MK-A010 )

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Herzlich Willkommen zu Ihrem Seminar: EASY - Ein intelligentes Steuerrelais ( MK-A010 )

  2. EASY600 EASY412

  3. Typenschlüssel - EASY.... Steuerrelais - EASY mm 2 = 35,5 mm 4 = 71,5 mm 6/8 = 107,5 mm = Display X = Display C = Clock E = Erweiterungs Modul I Q 12=8 4 --- 18 = 12 6 --- 19 = 12 6 erweiterbar 20 = 12 8 --- 21 = 12 8 erweiterbar R = Relais T = Transistor AC = 100 / 120 / 230/ 240 VAC DC = 24 VDC + 2 x 10VDC analog DA = 12 VDC

  4. Digitale Eingänge der EASY (-AC) >I 115/230VAC L N 2-Draht Initiatoren, Glimmlampe Distanz Strom S1 S2 40m 100m ( I7+I8=100m) L N I1 I1..I6/I9..I12 : 0,5mA - 230VAC 0,25mA - 115VAC I7,I8 : 6mA -i 230VAC 4mA -i 115VAC I > 0,5/0,25mA 100nF : 80ms - 50Hz 66,6ms - 60Hz R = 1 KOhm EASY256-HCI I1 I1

  5. Digitale Eingänge der EASY (-DC / -DA ) ~ 12VDC 0 ...10 VDC 24 / 12 VDC L01 + L01 - 1KOhm Distanz S1 2,2mA 100m 3,3mA alternativ 0V 0V I1 I7 I8 DC = 24VDC DA = 12VDC I1 I1

  6. Digitale Ausgänge der EASY-... -R EASY-...-T DC = 24VDC DA = 12VDC max. 10 A Q1 Q1 1 2 Q1 Q1 Q2 .... >=2,5A <= 8A / B16 24V= 8A 2A 115V~ 8A 2A 230V~ 8A 2A 24V= 0,5A 0,5A

  7. Übersicht der Schaltkontakte EASY 412 EASY600 Funktion Eingänge: I I I 1 .... I 8 I 1 .... I 12 I 13 „0“ I 14 Status Erweiterung I 16 I 15, I 16 Kurzschluß / Überlast R R R 1 .... R 12 Eingänge Erweiterung R 15, R 16 Kurzschluß / Überlast Ausgänge Q Q Q 1 .... Q 4 Q 1 .... Q 8 S S S 1 .... S 8 Ausgänge Erweiterung Merker M M M 1 .... M 16 M 1 .... M 16 Hilfsrelais

  8. EASY Ein-Ausgangserweiterung I 1.. 12 R 1... 12 EASY600 direkt EASY600-..-E.. S 1... 8 Q 1... 8 EASY200-EASY I15 =„1“ I 16 = „1“ >0,5A >0,5A EASY-LINK Q 5 ... Q 8 S 5 ... S 8 Q 1 ... Q 4 S 1 ... S 4

  9. Arbeitsweise der EASY Beispiel: I 1 I 2 Q 1 Q 1 . . . Q 1 Q 2 1.Zyklus 2.Zyklus I1 und I2 H H Q1 H H -Q1- L H Q2 L H Anzahl der Strompfade: EASY412 41 EASY600 121

  10. EASY Statusanzeige EASY 412-.. EASY 6xx-.. EASY 6xx-.. Erweiterung

  11. EASY - Spulenfunktionen Q.. S.. D.. Schütz- funktion : .. M.. Q.. S.. D.. Stromstoß- funktion M.. SQ.. SS.. Setzen (Verklinken) S SD.. SM.. RQ.. RS.. Rücksetzen (Entklinken) R RD.. RM..

  12. D C R EASY - Funktionsrelais s m,s h,m A I Q Clock B T C t ? D s m,s h,m I Q T D (Text) t A ? I 7 <= / >= I 8 I 8 >= / >= I 7 I 7 <= / >= 0.0 I 8 <= / >= 0.0 I Q Analog max. 100 Hz 0000... 9999 I Q C