220 likes | 308 Views
Multiple Indicator Cluster Surveys Data Processing Workshop. Data Entry Applications with Logic. Topics to be Discussed. what is the “path” of data entry? skip and reenter manipulating the path via procedures processing order in CSPro more commonly-used CSPro commands
E N D
Multiple Indicator Cluster SurveysData Processing Workshop Data Entry Applications with Logic MICS4 Data Processing Workshop
Topics to be Discussed • what is the “path” of data entry? • skipand reenter • manipulating the path via procedures • processing order in CSPro • more commonly-used CSPro commands • creating user-defined variables • adding messages to your program MICS4 Data Processing Workshop
The Data Entry Path • The data entry path contains all of the questions that a respondent should be asked • It is determined by • the type of the questionnaire • the responses to questions in conjunction with • questionnaire skips • questionnaire filters • It is controlled by logic you develop MICS4 Data Processing Workshop
Changing the path via skip CSPro has two ways of implementing skips: skip to Use if moving to a singly-occurring variable or to a roster: skip to <variable_name>; skip to <group_name>; skip to next Use if the var. being skipped to is in a repeating form/roster: skip to next <repeating_variable_name>; skip to next <group_name>; MICS4 Data Processing Workshop
Changing the path via reenter • To force the data entry operator to reenter the current field (e.g., if the data entered are inconsistent) use: reenter; • By default, reenter forces reentry of the current field. If you wish to force reentry of a previously-entered field, use: reenter <field_name>; MICS4 Data Processing Workshop
CSPro Procedure Types Global procedure (PROC GLOBAL) • logic executed when the Data Entry App begins Form File procedure (PROC <form_file_name>) • logic executed when the Data Entry App begins/ends Level procedure (PROC <level_name>) • logic executed when a level begins/ends Group procedure (PROC <group_name>) • logic executed when a form/roster begins/ends Variable procedure (PROC <variable_name>) • logic executed before/after a variable is keyed MICS4 Data Processing Workshop
preproc and postproc There are two types of procedures: preproc • logic executed before the item • for example, skip to another variable postproc • logic executed after item • for example, check if data entered is consistent • for example, skip to a variable • default action for logic if nothing explicitly written MICS4 Data Processing Workshop
Order of Operations PROC GLOBAL (executes at start of program, cannot stipulate preproc or postproc) Form File preproc Level 1 preproc Form 1.1 preproc Field 1.1.1 preproc Field 1.1.1 postproc repeat for other <Form 1.1 fields> Form 1.1 postproc repeat for other <Level 1 forms> Level 2 preproc Form 2.1 preproc Field 2.1.1 preproc Field 2.1.1 postproc Form 2.1 postproc repeat for other <Level 2 forms> Level 2 postproc Level 1 postproc Form File postproc MICS4 Data Processing Workshop
Ending a Level • You must prematurely finish a level if • the last variable in the data path is not the last variable on the questionnaire • there are no more woman or children’s under-five questionnaires left for the HH • This is accomplished using the endlevel command MICS4 Data Processing Workshop
The endlevel Command • The effect of the endlevel command depends upon its context/location: • In a field/roster/form proc, control passes to the current level’s postproc • In a level 2 or higher postproc, control passes to the next highest level’s postproc • In a level 1 proc, control passes to the application, i.e., the form file’s postproc MICS4 Data Processing Workshop
Operator vs. System Controlled • Operator-controlled: the keyer has some/ all control on the data entry path • System-controlled: the keyer has no control over the data entry path • go to options data entry • choose “system controlled” • (while you are there, make all alphanumeric variables upper case) MICS4 Data Processing Workshop
Ending a Group • A group is a roster or multiply-occurring form • Is terminated by using the endgroup command • Passes control to the group’s postproc—all intervening logic (in other form/roster items) is skipped MICS4 Data Processing Workshop
User-defined Variables • User-defined variables must be declared in the PROC GLOBAL section and as implied, are global in scope • Numeric working variables can be declared together • numeric var1, var2; • Alphanumeric variables must be declared separately: • alpha(length) avar1; • alpha(length) avar2; MICS4 Data Processing Workshop
User-defined Variables (cont) • All variables must be declared in the preproc of the form_files procedure • User-defined variables should be assigned a value within the preproc of the form_files, e.g., minab = 144; • You should give a description of your variable at either the place of declaration or initialization, e.g., numericminab; {min. age at first birth in months} MICS4 Data Processing Workshop
Recoding Variables • To more easily assign values to a variable based on another variable, use recode • The following logic recodes women’s age into groups: recode WB2 => agegrps; 15-19 => 1; 20-24 => 2; => 3; endrecode; MICS4 Data Processing Workshop
if command Use the if command to check for a condition: if HH9 <> 1then skip to HH16; endif; if (HH9=1and HH11=0) or (HH9 in2:4,6and HH11<>0) then reenter; endif; MICS4 Data Processing Workshop
Generating Error Messages • Example: If the cluster number is invalid, we can show the operator a message to explain what the problem is; for example, errmsg(“Cluster number invalid”); • However, to be more useful, we should tell them what the valid range is; to do this, we can pass in parameters to the command as follows: errmsg(“Cluster number invalid, expected range %d to %d”, MinClust, MaxClust); MICS4 Data Processing Workshop
Error Message Parameters • The values of any variables listed after the error message number will be passed to the error message • Parameters are displayed in the error message using • %d for numeric values • %s for alphanumeric values (i.e., text) MICS4 Data Processing Workshop
Streamlining Error Messages • Suppose we need to repeat the same message several times in the file—what should we do? • We can assign unique numbers to each error message • We can keep all error messages in the message file (.mgf) MICS4 Data Processing Workshop
Sample Error Messages • Our earlier message (and maybe one we could use for that HH result code earlier) would now be simplified to: errmsg(1, MinClust, MaxClust); errmsg(2, HH9, HH11); • And the message file would look something like: 0001 Cluster number invalid, expected range %d to %d 0002 HH result code (%d) doesn’t agree with number of HH members (%d) MICS4 Data Processing Workshop
Modifying Your Test Application • Add logic to • check if the household number is consistent • display message and add reenter command if not • implement the HH result code skip • check the date of interview is internally consistent • display message and force reentry if not • Compile your application, resolve any errors • Save your application (<ctrl+S>) MICS4 Data Processing Workshop
Testing your Application • Click once on the execute button on toolbar ( ), or press <ctrl+R> to run • Use NoData.dat as your datafile • Enter a case (i.e., a questionnaire) MICS4 Data Processing Workshop