Auxiliary Lighting

Auxiliary Scene Lighting. Pasco Fire Department. Auxiliary Lighting. In accordance with WAC 296-305-06008 (Electrical) – all auxiliary electrical equipment used by the Pasco Fire Department has been replaced. WAC 296-305-06008 requires:

tress
Download Presentation

Auxiliary Lighting

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Auxiliary Scene Lighting Pasco Fire Department Auxiliary Lighting

  2. In accordance with WAC 296-305-06008 (Electrical) – all auxiliary electrical equipment used by the Pasco Fire Department has been replaced. WAC 296-305-06008 requires: • Heavy Duty flexible cords with SO or SJ jackets or equivalent. • The path to ground from power cords, equipment, and temporary lights shall be continuous • Electrical equipment, tools, and temporary lights shall be constructed so that water cannot enter or accumulate in wireways, or other electrical parts. • Electrical equipment, that are used in wet or damp atmospheres shall have 120 VAC single-phase 15 or 20 amp in-line resettable ground fault circuit interrupters. • Temporary lights shall be equipped with a handle and be protected by guards of a nonconductive or insulated material to prevent accidental contact with the bulb. • Bodies and caps shall be weather tight, 20 amp rated at 120 VAC Pasco Fire Department Auxiliary Lighting

  3. WAC 296-305-06008 (Electrical) continued Pasco Fire Department • Cords on reels that do not exceed one hundred fifty feet in length shall be SO or SJ type jackets or equivalent. • Cord reels that are not permanently mounted on a vehicle shall be insulated from the ground when in use. Auxiliary Lighting

  4. System Components Pasco Fire Department • In-line resettable ground fault circuit interrupters. • 120 VAC single-phase 15 or 20 amp. • MUST be connected to the vehicle Auxiliary Lighting

  5. System Components • 120 VAC cord reels • Connected to the in-line resettable ground fault circuit interrupters. • 120 VAC cord reels shall be approved for use in wet or damp locations or hazardous atmospheres. • Bodies and caps shall be weather tight, 20 amp rated. • Cord reels that are not permanently mounted shall be insulated from the ground when in use. Pasco Fire Department Auxiliary Lighting

  6. System Components • Junction Box • Lit when it has power • 4 weather tight twist lock outlets (2 on each side) • 120 VAC 20 amp. Pasco Fire Department Auxiliary Lighting

  7. System Components • Extension Cord • Cord reels carry 100 ft. of cord • Yellow extension cords are 50 ft. • Black extension cords are 25 ft. Pasco Fire Department Auxiliary Lighting

  8. System Components • Temporary Light • Temporary lights shall be equipped with a handle and be insulated from heat and possible electrical shock • Shall be protected by guards of a nonconductive or insulated material to prevent accidental contact with the bulb. Pasco Fire Department Auxiliary Lighting

  9. System Components • Pig Tails • Must be approved for use in wet or damp locations or hazardous atmospheres • Have SO or SJ type jackets or equivalent. • Bodies and caps shall be weather tight, 20 amp rated at 120 VAC. Pasco Fire Department Auxiliary Lighting

  10. The Set Up Pasco Fire Department Start the generator and allow to warm up. Attach the in-line resettable ground fault circuit interrupter to the chosen outlet on the vehicle. Auxiliary Lighting

  11. The Set Up Pasco Fire Department Attach Cord reel or extension cord to the in-line resettable ground fault circuit interrupter. Attach tool or junction box. Auxiliary Lighting

  12. The Set Up From the Junction Box Attach extension cord (Yellow = 50 ft, Black = 25 ft.) to an outlet in the junction box Attach tool to the extension cord. Pasco Fire Department Auxiliary Lighting

  13. Pasco Fire Department Reference and Review PFD SOG – 30-8.3.1 Auxiliary Electrical Power Supply Equipment and Set Up Auxiliary Lighting

  14. Pasco Fire Department Auxiliary Lighting