1 / 49

Essentials of Fire Fighting , 5 th Edition

Essentials of Fire Fighting , 5 th Edition. Chapter 14 — Fire Streams Firefighter II. Chapter 14 Lesson Goal.

truman
Download Presentation

Essentials of Fire Fighting , 5 th Edition

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Essentials of Fire Fighting, 5th Edition Chapter 14 — Fire Streams Firefighter II

  2. Chapter 14 Lesson Goal • After completing this lesson, the student shall be able to effectively apply fire fighting foam using various foam types, concentrates, and delivery devices following the policies and procedures set forth by the authority having jurisdiction (AHJ). Firefighter II

  3. Specific Objectives 1. Describe the suppression characteristics of fire fighting foam. 2. Define terms associated with types of foam and the foam-making process. 3. Discuss how foam is generated. (Continued) Firefighter II

  4. Specific Objectives 4. Discuss foam concentrates. 5. Describe methods by which foam may be proportioned. 6. Discuss foam proportioners. 7. Discuss foam delivery devices. (Continued) Firefighter II

  5. Specific Objectives 8. List reasons for failure to generate foam or for generating poor-quality foam. 9. Describe foam application techniques. (Continued) Firefighter II

  6. Specific Objectives 10. Discuss hazards associated with foam concentrates. 11. Place a foam line in service — In-line eductor. (Skill Sheet 14-II-1) Firefighter II

  7. Ways Fire Fighting Foam Extinguishes/Prevents Fire • Separating • Cooling • Smothering • Penetrating Firefighter II

  8. Terms Associated With Foam • Foam concentrate • Foam proportioner • Foam solution • Foam (finished foam) Firefighter II

  9. How Foam is Generated • Foams used today are of mechanical type and before use must be • Proportioned • Aerated (Continued) Firefighter II

  10. How Foam is Generated • Elements needed to produce fire fighting foam (Continued) Firefighter II

  11. How Foam is Generated • All elements must be present and blended in correct ratios • Aeration produces foam bubbles to form effective foam blanket Firefighter II

  12. Foam Expansion • The increase in volume of foam when aerated • Method of aerating results in varying degrees of expansion • Types of foam Firefighter II

  13. Foam Concentrates — General Considerations • Foam concentrates must match fuel to which applied • Class A foams not designed to extinguish Class B fires • Class B foams designed solely for hydrocarbon fires will not extinguish polar solvent fires Firefighter II

  14. Class A Foam • Increasingly used in both wildland and structural fire fighting • Special formulation of hydrocarbon surfactants (Continued) Firefighter II

  15. Class A Foam • Aerated Class A foam coats, insulates fuels, preventing pyrolysis and ignition • May be used with variety of nozzles Firefighter II

  16. Class B Foam • Used to prevent ignition of or extinguish fires involving flammable and combustible liquids • Used to suppress vapors from unignited spills of these liquids • Several types of Class B foam concentrates available (Continued) Firefighter II

  17. Class B Foam • Manufactured from synthetic or protein base • May be proportioned into the fire stream through fixed system, apparatus-mounted system, or by portable foam proportioning equipment (Continued) Firefighter II

  18. Class B Foam • Foams such as AFFF and FFFP foam may be applied with standard fog nozzles or air-aspirating foam nozzles • Rate of application depends on several factors (Continued) Firefighter II

  19. Class B Foam • Unignited spills do not require same application rates as ignited spills • To be most effective, blanket of foam 4 inches (100 mm) thick should be applied to fuel surface Firefighter II

  20. Specific Application Foams • Numerous types of foam available for specific applications • Properties of foams vary Firefighter II

  21. Proportioning • Mixing of water with foam concentrate to form foam solution • Most concentrates can be mixed with fresh/salt water (Continued) Firefighter II

  22. Proportioning • For maximum effectiveness, foam concentrates must be proportioned at designated percentage • Most fire fighting foams intended to be mixed with 94 to 99.9 percent water Firefighter II

  23. Proportioning Methods • Induction • Injection • Batch-mixing • Premixing Firefighter II

  24. Foam Proportioners — General Considerations • May be portable or apparatus-mounted • Operate by one of two basic principles Firefighter II

  25. Portable Foam Proportioners • Simplest, most common form of proportioning devices • In-line foam eductors • Foam nozzle eductors Firefighter II

  26. Apparatus-Mounted Proportioners • Mounted on structural, industrial, wildland, and aircraft rescue and fire fighting apparatus, as well as on fire boats • Three types Firefighter II

  27. Compressed-Air Foam Systems (CAFS) • Newer structural engines are equipped with CAFS (Continued) Firefighter II

  28. Compressed-Air Foam Systems (CAFS) • Standard centrifugal pump supplies water, direct-injection foam-proportioning system mixes foam solution with water on discharge side of pump, onboard air compressor adds air to mix before discharging from engine (Continued) Firefighter II

  29. Compressed-Air Foam Systems (CAFS) • Unlike other systems, hoseline contains finished foam • Advantages • Disadvantages Firefighter II

  30. Handline Nozzles • Solid-bore nozzles • Fog nozzles • Air-aspirating foam nozzles Firefighter II

  31. Medium- and High-Expansion Foam Generating Devices • Produce foam that is semistable with high air content • Medium-expansion foam • High-expansion foam • Water-aspirating type nozzle • Mechanical blower generator Firefighter II

  32. Reasons for Poor-Quality Foam/Failure to Generate Foam • Eductor, nozzle flow ratings do not match so foam concentrate cannot induct into fire stream • Air leaks at fittings cause loss of suction • Improper cleaning of proportioning equipment causes clogged foam passages (Continued) Firefighter II

  33. Reasons for Poor-Quality Foam/Failure to Generate Foam • Nozzle not fully open, restricting water flow • Hose lay on discharge side of eductor is too long • Hose is kinked and stops flow (Continued) Firefighter II

  34. Reasons for Poor-Quality Foam/Failure to Generate Foam • Nozzle is too far above eductor • Mixing different types of foam concentrate in same tank results in mixture too viscous to pass through eductor Firefighter II

  35. Roll-On Foam Application Method • Directs foam stream on ground near front edge of burning liquid spill • Foam rolls across surface of fuel (Continued) Firefighter II

  36. Roll-On Foam Application Method • Firefighters continue to apply foam until spreads across entire surface of fuel and fire extinguished • Used only on pool of liquid fuel on open ground Firefighter II

  37. Bank-Down Foam Application Method • May be employed when elevated object is near/within area of burning pool of liquid or unignited liquid spill • Object may be wall, tank shell, similar vertical structure (Continued) Firefighter II

  38. Bank-Down Foam Application Method • Foam stream directed onto object, allowing foam to run down onto surface of fuel • Used primarily in dike fires, fires involving spills around damaged/overturned transport vehicles Firefighter II

  39. Rain-Down Foam Application Method • Used when other two methods not feasible because of size of spill area or lack of object from which to bank foam (Continued) Firefighter II

  40. Rain-Down Foam Application Method • Primary manual application technique on aboveground storage tank fires • Directs stream into air above fire/spill, allows foam to float gently down onto surface of fuel Firefighter II

  41. Foam Hazards to Humans • Foam concentrates pose minimal health risks to humans • May be mildly irritating to skin, eyes (Continued) Firefighter II

  42. Foam Hazards to Humans • Affected areas should be flushed with water • Some concentrates, vapors may be harmful if ingested/inhaled • Consult MSDS for specific information Firefighter II

  43. Foam Hazards to Equipment • Most Class A, Class B foam concentrates are mildly corrosive • Follow proper flushing procedures to prevent damage Firefighter II

  44. Foam Hazards to Environment • Primary impact is effect of finished foam after application to fire/liquid spill • Biodegradability of foam determined by rate at which environmental bacteria cause decomposition (Continued) Firefighter II

  45. Foam Hazards to Environment • Environmental impact of foam concentrates varies • In the U.S., Class A foams should be approved by USDA Forest Service (Continued) Firefighter II

  46. Foam Hazards to Environment • Chemical properties of Class B foams and environmental impact vary on type and manufacturer • Protein-based foams safer for environment (Continued) Firefighter II

  47. Summary • Firefighters must know the differences between the classes of foam, how to generate foam, and how to apply foam most effectively Firefighter II

  48. Review Questions 1. What are the ways that fire fighting foam extinguishes and/or prevents fire? 2. Describe types of foam concentrates. 3. What are the methods by which foam may be proportioned? (Continued) Firefighter II

  49. Review Questions 4. What are the types of portable foam proportioners and how do they work? 5. Describe the techniques used to apply foam. Firefighter II

More Related