220 likes | 451 Views
www.pyronix.com. Pyronix House, Braithwell Way, Hellaby, Rotherham, South Yorkshire, S66 8QY, England Tel +44 1709 700 100, Fax +44 1709 533 429. Matrix 832 Main Board. 17V DC Power supply 7,2 A/H 12V AC Battery Dedicated Bell (+/-) supply Dedicated Bell Tamper Global System Tamper
E N D
www.pyronix.com Pyronix House, Braithwell Way, Hellaby, Rotherham, South Yorkshire, S66 8QY, England Tel +44 1709 700 100, Fax +44 1709 533 429
Matrix 832 Main Board • 17V DC Power supply • 7,2 A/H 12V AC Battery • Dedicated Bell (+/-) supply • Dedicated Bell Tamper • Global System Tamper • PGM 1 N/O-N/C(Relay) • PGM 2 • PGM 3 • PGM 4 • KD - System bus output • Zones 1-4 • +AUX- • Zones 5-8 • GND connection • Telephone line - heavy duty lighting protection • RS 232 output • Local zone expander slot for 8/16 zones expander • NVM reset pin
Matrix Expanders • Zone expanders: - Local plug in 8/16 zone expander - plug on the main board - Remote 8/16 zone expander - on the bus • PGM expanders: - 8 PGM transistor expander - on the bus - 8 PGM relay expander - on the bus
Matrix Keypads - MX-LED Keypad: - 2 seven segment display - Icon based - 9 status LED - PA, Fire and Medical buttons - Public & Private mode - Addressable per partition number - MX-LCD Keypad: - 16 characters LCD display - Multilingual - PA, Fire and Medical buttons - Public & Private mode - Addressable per partition number
Matrix Proximity Reader • Proximity reader: - Bus proximity reader - 5 Status LED indication - Proximity card - Proximity tag - Public & Private mode - Addressable per partition number - Activate / Disactivate PGM’s
Matrix PC Software • Matrix UDL software: - Local RS232 and modem connection - Used for Programming the system - Multilingual support - Proximity tag • Matrix PC Maintenance / Monitoring software: - Modem connection - Used for programming and monitoring the system - Multilingual support
AC fail warning - enable / disable • AC frequency - 50 / 60 Hz • Battery monitoring - enable / disable • Global tamper activation polarity - 0V or 12V • NVM reset - from engineer mode and link / link only • Real time clock - AC / Quartz based • EVENT MEMORY - 300 events with time & date • Alarm in telephone line fail - enable / disable • Limit log and event reporting - enable / disable • Tamper on bus device missing - enable / disable • Put Restorals In Log • Arm Mode Settings • Engineer Lockout Global System Options
Zone Configurations - max 32 zones • Zone attributes: - Chime - Test - Mask Any zone can have different attribute. Zone types: - Entry / Exit - Access - Immediate - Omitted (Bypassed) - Fire - Personal Attack - 24 H - Tamper - Latch Keyswitch - - Momentary Keyswitch - Medical - Unused Each zone type can be allocated to one zone at a time. • Zone configurations: - N/C - DEOL - Zone Doubling - Fast Zone response These options are global. • Zone partition allocation: - Partition 1 - Partition 2 - Partition 3 - Partition 4 Each zone can be allocated to only one partition.
Example Installation Partition 1 Partition 2 Partition 3 Partition 4
User Codes - max 32 codes • User codes attributes: - Omit (Bypass) zones - Duress code - Duress disable - Arm code - Disarm code - Temporary code • User code types: - Master user code - Limited user code • User codes partition allocation: - Partition 1 - Partition 2 - Partition 3 - Partition 4 - Any combination from the above
Example User Codes Configuration Code 1 - Master User Code 2-5 - Limited User Code 14 - Duress Code 15 - Cleaner Code 16 - Patrol Code 1-16 allocated to the P1 Partition 1 Partition 2 Code 6 - Master User Code 7-9 - Limited User Code 14 - Duress Code 10- Master User Code 11-13 - Limited User Code 14 - Duress Partition 3 Partition 4
Partition 1 • Partition 2 • Partition 3 Arm Modes • Partition 4 • Arm mode A: - Timed exit - Final exit - Silent arm - Home / Away - Key zone arm • Arm mode B: - Timed exit - Final exit - Silent arm - Home / Away - Key zone arm • Arm mode C: - Timed exit - Final exit - Silent arm - Home / Away - Key zone arm • Arm mode D: - Timed exit - Final exit - Silent arm - Home / Away - Key zone arm
Global timers - all partitions: - AC fail delay report, RTC correction factor • Partition timers : - Partition 1 - Partition 2 - Partition 3 Timers - Partition 4 Partition 1: - Bell time - Entry time - Exit time - Bell delay - Final exit delay - Inactivity auto-arm - Auto-arm at hour Partition 2: - Bell time - Entry time - Exit time - Bell delay - Final exit delay - Inactivity auto-arm - Auto-arm at hour Partition 3: - Bell time - Entry time - Exit time - Bell delay - Final exit delay - Inactivity auto-arm - Auto-arm at hour Partition 4: - Bell time - Entry time - Exit time - Bell delay - Final exit delay - Inactivity auto-arm - Auto-arm at hour
System Partition Options - Matrix is optioned with 4 partitions - virtually independent systems with common hardware. To each of them can be allocated one or more of the following devises/attributes: • Keypad - 1 up to 4 • Proximity reader - 1 up to 4 • Zones - 1 up to 32. Any zone type available from the menu • PGM - 1 up to 12. Any PGM type available from the menu • Arm modes - 4 arm modes available per partition • Account code - One a/c per partition • User codes - 1 up to 32. Any user code attribute available from the menu • Partition dependency - any combination • Partition options - independently programmable per partition
Partition Dependency - Common Partition • Area 1 - Armed in Away mode • Partition 3 - Armed in Away mode • Partition 2 - Armed in Away mode • Area 4 - This will arm when all areas armed in Away mode
PGM polarity: - N/C - N/O • Programmable Outputs: - E- - C+ - Controlled from keypad - Follow zone - Follow telephone line fail - Follow kiss off - Shock / fire sensor reset - Strobe - Follow PA alarm - Follow confirmed alarm - Follow tamper alarm - Bell - GRN fire detector - Twin Alert - Follow Fault - General Fault • RS 232 output Outputs • PGM partition allocation : - up to 12 PGM can be allocated to any of the available 4 partitions
Matrix Digital Communicator • Communication to Servicing company • Communication Formats: - Contact ID - Fast Format - PC format - Pager format - Voice • Communication to user • Communication to Monitoring company
Communication Formats: - Contact ID - Fast Format Communication to Monitoring company • Events Send Options: Disarmed A, B, C, D Restorals Alarm Alarm Alarm PA alarm PA alarm PA alarm Fire alarm Fire alarm Fire alarm Maintenance Maintenance Maintenance Open /Close Open /Close Open /Close • Events Group reporting To telephone n. 1 To telephone n. 1+2 To both numbers If programmed any event will be send to n. 3 • Communication Options: - 4 account codes - Test dial - min or days - 9 telephone numbers - 3 numbers for group reporting - Telephone line monitoring - Send open after alarm - AMC dial in mode - Communication priority events
Communication Formats: - PC Pyronix format Communication to Servicing Company • Matrix UDL software: - Local RS232 and modem connection - Used for Programming the system - Multilingual support • Matrix PC Maintenance / Monitoring software: - Local RS232 and modem connection - Used for programming and monitoring the system - Multilingual support • Communication Options: - 4 account codes - Test dial - min or days - 9 telephone numbers - 3 numbers for group reporting - Telephone line monitoring - Send open after alarm - AMC dial in mode - Communication priority events
Communication to the User • Communication Formats: - Pager forma - Voice
End Presentation Thank you very much for choosing Pyronix products