1 / 36

Principle and Application of GC-MS

Principle and Application of GC-MS. 2012-09-17. Content. GC-MS &HPLC-MS Instrument and column Sample preparation Preferences Application in my research. GC-MS &HPLC-MS. Preface Differences . 1.Principle polar VS non-polar 2. Mobile phase liquid VS gas 3. Ionization way

tyrone
Download Presentation

Principle and Application of GC-MS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Principle and Application of GC-MS 2012-09-17

  2. Content • GC-MS &HPLC-MS • Instrument and column • Sample preparation • Preferences • Application in my research

  3. GC-MS &HPLC-MS • Preface • Differences 1.Principle polar VS non-polar 2. Mobile phase liquid VS gas 3. Ionization way EI,CI VS ESI, APCI 4.Application heat stability

  4. Principle of GC-MS • 物理分离方法; • 组份沸点差异 &分配系数的差异; • 质谱检测器----电离源----质谱碎片----谱库检 索----匹配度----完成定性。

  5. Process of GC-MS

  6. Manufacturer of GC-MS • 美国Agilent • 日本岛津 Shimadzu

  7. 6890N/5973C

  8. Chromatographic column • Capillary column and packed column

  9. Preferences of capillary column • 内径(inner diameter):0.25mm • 高柱效,低负荷量,必须分流进样或无分流进样。 • 用于复杂多组份样品分析。 • 柱长(column length ):30m • 25—30m 中长柱:分离10—50个组份。     50m 长柱:分离大于50个组份或包含有难分离物质。 • 膜厚(film sickness):0.25—0.33μm • 对于流出达300℃的大多数样品(包括蜡、甘油三酯、甾族化合物等)能够很好的分析。 • 固定液(stationary liquid) 分析时间加倍,分辨率增加40%

  10. stationary liquid ---“相似相溶” • a. 非极性物质—非极性固定液;低沸点组分 • b. 极性物质—极性固定液;小极性组分 • c. 极性与非极性混合物—极性固定液;小极性组分 • d. 易形成氢键物质—极性或氢键型固定液; 不易形成氢键的组分 • e. 复杂难分离样品—多种固定液混合;

  11. Sample preparation • Without water and salt; • Organic solvent with low boiling point; • 丙酮、正己烷、氯仿、苯等 • 毛细管柱样品浓度mg/ml级或更低; • 进样量----进样方式而定 • sample derivatization(样品衍生化)

  12. sample derivatization • 硅烷化 • 酰化 • (1)乙酰化(体内药物筛选,大多数的临床药物) (2)三氟乙酰化/五氟丙酰化/七氟丁酰化(苯丙胺类和麻黄碱类) • 烷基化(农药和杀虫剂) • 目的:改善待测物质的气相色谱性质如热稳定性、分子质量、质谱行为;

  13. Preferences of GC-MS ----sample injection • 自动进样(auto-injection) • 手动进样(hand-injection)

  14. split or not?split ratio? • 分流(split)----主要组分分析; • 脉冲分流(pulse split)----允许更大进样量; • 不分流(splitless)---- 痕量组分分析; • 脉冲不分流(pulse splitless)----允许更大进样量。

  15. carrier gas • hydrogen ,nitrogen, argon, helium, Carbon dioxide • flow rate:i.d<0.25mm:0.5-3ml/min; • 0.32mm: 5-10ml/min; • 0.53mm: 5-20ml/min • i.d<0.32mm,衡流模式,1.0ml/min;

  16. temperature of inlet • 考虑样品的稳定性? • 样品是否能够瞬间气化? • 一般在200~250℃

  17. column temperature program • 影响样品分离度的最主要因素; • 升温慢可改善分离效果,增加分析的时间; • 升温快会加快载气流速,相近组分难完全分离; • 柱温极限;

  18. Selection principle • 在使最难分离的组分尽可能好的分离的情况下,尽可能采取 较低的柱温,但以保留时间适宜,峰形不拖尾为度。 • 高沸点300-400℃,低于其沸点100-200℃; • 沸点200-300℃,中等柱温; • 沸点100-200 ℃ ,平均沸点的2/3左右 • 气体,气态烃等,沸点或沸点以上

  19. Ionization source for GC-MS • 样品分子 ---- 带电的离子 ----离子束----质量分析器 • EI:NIST标准谱库,70eV,230℃,易挥发 成分 • CI:软电离技术,EI分析不了的物质,非标准质谱图 • FAB, ESI, APCI for HPLC-MS

  20. Mass detector分辨率, 灵敏度, 扫描速度

  21. Data acquisition • 全扫描(Scan)VS选择离子扫描(SIM) • 灵敏度:SIM比Scan的高三个数量级 • 阈值的设置:为限制采集的峰数

  22. Qualitative analysis • Library, • 一般为probability-based matching(PBM)检索 • 匹配度≥80, • else AMDIS • Research

  23. library • NIST:美国国家科学技术研究所出版 • NIST/EPA/NIH:美国国家科学技术研究所、美国环保局、 美国国立卫生研究院共同出版 • Wiley库:3个版本,同一化合物可能有重复的不同来源的 质谱图 • 农药库、药物库、挥发油库 • 前三个通用,后三个专用,NIST/EPA/NIH库应用最广泛。

  24. Some advice • 1 EI,70eV for NIST • 2 纯化合物的质谱图 Subtract Background(BSB) & Savitzky-Golay • 3 匹配度(相似度)& 其他有关信息

  25. Influencing factor for library searching • 仪器调谐方式不对 • 数据采集时最强峰超量程 • 采集数据或处理谱图时设定的低质量范围过高 • 色谱分离不好,或本底峰干扰严重 • 检索参数的选择(如质量范围等)

  26. Quantitative analysis • 面积归一化法(area normalization method) • 外标法(external standard method) • 内标法(internal standard method)

  27. Area normalization method • 方法:各组分浓度以面积百分率表示,可确认大概的浓度,但有误差; • 要求: • 1)所有物质都出峰,各物质响应因子接近,主要物质含量足够大,各峰型都较尖锐且对称; • 2)峰高,只要不超过检测的线性范围最大值的一半就行;

  28. External standard method • 目前应用最广泛的方法之一; • 误差来源:主要是进样误差; • 解决办法:分析前一定要做面积重复性(即进样重复性)实验

  29. Internal standard method • 在样品中添加等体积等浓度的内标物,通过组分与内标峰 的面积比,对组分进行定量; • 内标物选择原则: • 内标物的峰与试样中的所有成分的峰完全分离; • 内标物的峰与目标成分的峰保留时间不应差太远; • 内标物具有与分析目标成分类似的化学性质

  30. Integrator of chromatographic peak • RTE Integrator • ChemStation Integrator

  31. RTE • 相对简单的色谱图(其中的峰很窄且已完全解析) • 尤其适用于 target compound analyses(目标化合物分析) • 缺省参数 • 整个色谱图范围内;毛细管色谱柱;总离子流 (TIC)

  32. ChemStation Integrator • 各种类型色谱图的积分方便,直观,准确 • 带有难于处理的基线和负峰的色谱图 • 但自动编辑定量时,用RTE较好

  33. Application in my research • 6890/5973, Agilent • auto sampler (7683B, Agilent) • Agilent HP-5MS capillary column (30m×0.25mm i.d., 0.25μm film), • 1μl extracts solution (1g/ml, extracts/methanol) & n-Tridecane • split ratio 10:1 • helium (1.0ml/min). • column temperature programwas : • 60℃(1 min), 60-140℃at 4℃/min, 140℃(10min), 140-155℃at 3℃/min,155℃(2min),155-250℃at 20℃/min,250℃(1min). • EI,70eV; • Inlet--250℃, ionization source --230℃, MS detector --150℃ • scan,m/z 40-500.

  34. 参考文献 • 1. N.Y. Qin, F.Q. Yang, Y.T. Wang, S.P. Li. Quantitative determination of eight components in rhizome (Jianghuang) and tuberous root (Yujin) of Curcuma longausing pressurized liquid extraction and gas chromatography–mass spectrometry[J]. Journal of Pharmaceutical and Biomedical Analysis, 2007,43:486–492. • 2.Li, M (Li, Ming), Zhou, X (Zhou, Xin), Zhao, Y (Zhao, Yang), Wang, DP (Wang, Dao-Ping) ,Hu, XN (Hu, Xiao-Na). Quality Assessment of Curcuma longa L. by Gas Chromatogrotphy-Mass Spectrometry Fingerprint, Principle Components Analysis and Hierarchical Clustering Analysis.Bulletin of The Korean Chemical Society[J].2009,30(10):2287-2293. • 3. http://www.instrument.com.cn/netshow/SH100320/ • 4.http://www.home.agilent.com/agilent/home.jspx?cc=CN&lc=chi • 5.汪正范,杨树民,吴侔天等. 色谱连用技术[M].化学工业出版社.2001. • 6.王光辉, 熊少祥. 有机质谱解析[M]. 化学工业出版社 . 2005.

  35. Thank you!