Elimination of 2L Minimum Sample POE systems and components

Tab 8: DWA-61-2013-11. Elimination of 2L Minimum Sample POE systems and components. Peter Greiner, NSF International DWAJC Meeting - December, 2013. 2L Sample Mandate for POEs. Tab 8: DWA-61-2013-11. Originated from material safety test in DWTU standards. 2L Sample Mandate for POEs.

udell
Download Presentation

Elimination of 2L Minimum Sample POE systems and components

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Tab 8: DWA-61-2013-11 Elimination of 2L Minimum SamplePOE systems and components Peter Greiner, NSF International DWAJC Meeting - December, 2013

  2. 2L Sample Mandate for POEs Tab 8: DWA-61-2013-11 • Originated from material safety test in DWTU standards

  3. 2L Sample Mandate for POEs Tab 8: DWA-61-2013-11 • Originated from material safety test in DWTU standards • DWTU standards only use 1 test water chemistry

  4. 2L Sample Mandate for POEs Tab 8: DWA-61-2013-11 • Originated from material safety test in DWTU standards • DWTU standards only use 1 test water chemistry • POEs now evaluated under NSF/ANSI 61 and are evaluated to three different waters (pH 5, 10, and 8)

  5. 2L Sample Mandate for POEs Tab 8: DWA-61-2013-10 • Originated from material safety test in DWTU standards • DWTU standards only use 1 test water chemistry • POEs now evaluated under NSF/ANSI 61 and are evaluated to three different waters (pH 5, pH 10, and pH 8) • Means a mandate of three times as many samples under NSF/ANSI 61 which may not be needed for analytical reasons.

  6. 2L Sample Mandate for POEs Tab 8: DWA-61-2013-11 • Originated from material safety test in DWTU standards • DWTU standards only use 1 test water chemistry • POEs now evaluated under NSF/ANSI 61 and are evaluated to three different waters (pH 5, pH 10, and pH 8) • Means a mandate of three times as many samples under NSF/ANSI 61 which may not be needed for analytical reasons. • Recommend removal of mandated 2L minimum.

  7. 2L Sample Mandate for POEs Tab 8: DWA-61-2013-11 Proposed revision:

  8. 2L Sample Mandate for POEs Tab 8: DWA-61-2013-11 Proposed revision: Note: Additional units are to be exposed if additional extraction water is needed to complete analysis…

  9. Thanks…! Pete Greiner greinerp@nsf.org 734-769-5517