1 / 19

DATA CENTER: PENDAHULUAN

DATA CENTER: PENDAHULUAN. Indikator Penilaian. Dasar Menyebutkan masalah ruang, energi dan biaya yang berkaitan dengan pebangunan, pemeliharaan dan pengembangan sebuah data center Menyebutkan tingkatan tier pada data center Menengah

ulric
Download Presentation

DATA CENTER: PENDAHULUAN

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DATA CENTER: PENDAHULUAN

  2. Indikator Penilaian • Dasar • Menyebutkan masalah ruang, energi dan biaya yang berkaitan dengan pebangunan, pemeliharaan dan pengembangan sebuah data center • Menyebutkan tingkatan tier pada data center • Menengah • Menjelaskan masalah ruang, energi dan biaya yang berkaitan dengan pembangunan, pemeliharaan dan pengembangan sebuah data center • Menjelaskan tingkatan tier pada data center disertai syarat-syarat pemenuhannya • Mahir • Memecahkan masalah ruang, energi dan biaya yang berkaitan dengan pebangunan, pemeliharaan dan pengembangan sebuah data center • Menerapkan tingkatan tier pada data center disertai syarat-syarat pemenuhannya

  3. Fungsidarimasing-masingkomponenpembentuksebuah data center!

  4. Komponen Utama Data Center • Kapasitas Catu Daya (power capacity) • Kapasitas Pendingin (cooling capacity) • Pengkabelan (cabling) • Pengaturan Suhu dan Kelembaban (temperature and humidity control) • Sistem pengaman kebakaran (fire and smoke system) • Keamanan Fisik (physical security) • Penataan ruang rak dan lantai (rack space and raised floor)

  5. Permasalahan yang Berkaitandengan Data Center: Ruang, EnergidanBiaya

  6. Tier pada Data Center

  7. Tier Untuk Aspek Umum Pada Data Center • Tier 1 (Basic) • Tier 2 (Redundant Components) • Tier 3 (Concurently Maintainable) • Tier 4 (Fault Tolerance)

  8. TeknologiGreen Data Center

  9. Kenapa? • The energy used by the nation’s servers and data centers is significant. It is estimated that this sector consumed about 61 billion kilowatt-hours (kWh) in 2006 (1.5 percent of total U.S. electricity consumption) for a total electricity cost of about $4.5 billion. Ref: http://www.energystar.gov/ia/partners/prod_development/downloads/EPA_Datacenter_Report_Congress_Final1.pdf?98dd-8295

  10. Topik Utama Pada Green Data Center • Konsumsi energi • Ramah lingkungan

  11. Tolak Ukur Konsumsi Energi • Power Usage Effectiveness (PUE) • Energy Reuse Effectiveness (ERE) • Data Center Compute Efficiency (DCcE)

  12. Power Usage Effectiveness (PUE) • Perbandingan total energi terhadap total energy yang di konsumsi perangkat IT. • PUE = Total Energy/IT Energy • Total energy termasuk: Pendingin + Catu daya + Penerangan + Perangkat IT • rentang nilai: 1 <= PUE <= ~ • Partial PUE (pPUE) = PUE secara parsial

  13. PUE/pPUE • PUE = 2700/2000 = 1.35 • PPUE1= 1700/1500 = 1.13 • PPUE2= 700/500 = 1.40

  14. Energy Reuse Effectiveness (ERE) • ERE = (Total Energy - Reused Energy)/IT Energy • rentang nilai : 1 <= PUE <= 1 • ERF ( Energy Reuse factor) • ERF = Reuse Energy / Total Energy • range: 0 <= PUE <= ~ • ERE = (1-ERF) / PUE

  15. Data Center Compute Efficiency (DCcE) • Server Compute Efficiency (ScE) Efisiensi Penggunaan sumberdaya komputasi pada sebuah server/mesin • DCcE = akumulasi rata2 dari ScE

  16. Contoh Umum untuk Mencapai Data Center yang Efisien • Mencapai Green Data Center: • Konsolidasi Server • Kurangi pembatas internal dalam institusi/usaha • Gunakan/Aktifkan fitur power management • Upgrade ke server dengan spesifikasi yang effisien dalam penggunaan energi • Gunakan Catu Daya Dengan Efisiensi tinggi • Patuhi Standarisasi Terkait • Dorong Perubahan Pada Tingkat Produsen/Vendor

  17. TUGAS 02b • Buat resume perkuliahan minggu ini, termasuk diskusi! (senin, 27/02/2012 dan jum'at 02/03/2012). KETERANGAN: • Catatan/ringkasan minimal 1 halaman. • Dapat berupa kombinasi tulisan dan diagram korelasi/mindmap. • jangan lupa tulis referensi. • file disimpan dalam format yg dapat dibaca oleh (microsoft|open)office atau pdf. • perhatikan ukuran file, jika besar, tolong dikompres. • pertimbangkan bahwa seluruh peserta milis akan menerima file tersebut!

  18. Tugas 02b(Lanjutan) • Aturan: subject email : 02b_NIM_NAMA nama file : 02b_NIM_NAMA_Judul/Keterangan lain Batas waktu : Minggu, 4 Maret 2012 jam 23:59 • Kirim ke: tk2154-201201@kelas.yusandra.info

  19. TERIMA KASIH

More Related