1 / 10

METHODS FOR MEASURING THE BEAM PROFILE IN HIGH INTENSITY BEAMS

METHODS FOR MEASURING THE BEAM PROFILE IN HIGH INTENSITY BEAMS. Charlotte Roose www.europeanspallationsource.se May 8, 2014. EUROPEAN SPALLATION SOURCE. An European multi-disiplinary research centre based on the world’s most powerful neutron source .

urbain
Download Presentation

METHODS FOR MEASURING THE BEAM PROFILE IN HIGH INTENSITY BEAMS

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. METHODS FOR MEASURING THE BEAM PROFILE IN HIGH INTENSITY BEAMS Charlotte Roose www.europeanspallationsource.se May 8, 2014

  2. EUROPEAN SPALLATION SOURCE An European multi-disiplinary research centre based on the world’s most powerful neutron source Hosted by Sweden (source facility) and Danemark (data management facility)

  3. SITE Start the construction this year !!

  4. ACCELERATOR 352.21 MHz 704.42 MHz 2.4 m 4.6 m 3.8 m 39 m 56 m 77 m 179 m Target High β Source LEBT RFQ MEBT DTL Spokes Medium β HEBT & Contingency 75 keV 3.6 MeV 90 MeV 216 MeV 571 MeV 2000 MeV Cold linac Warm linac Deadline for the transverse beam profile monitors

  5. Non-invasive Profile Monitor (NPM) 352.21 MHz 704.42 MHz 2.4 m 4.6 m 3.8 m 39 m 56 m 77 m 179 m Target High β Source LEBT RFQ MEBT DTL Spokes Medium β HEBT & Contingency 75 keV 3.6 MeV 90 MeV 216 MeV 571 MeV 2000 MeV 1 2 1 1 3 1 4 Cold linac Warm linac Use the interaction between the beam and the residual gas (Hydrogen) 10-7 - 10-8 mbar 10-9mbar Ionisation profile monitor Luminescence profile monitor

  6. NPM – Luminescence Profile Monitor Ionbeam Viewport (1) • Space of 10 cm maximum • 10-7 - 10-8mbar Picture Setup@ Zerstörungsfreie Profilmessung intensiver Schwerionenstrahlen, Frank Becker, Darmstadt, 2010

  7. NPM – Ionisation Profile Monitor • 40 cm of space or less • Dimension = 10cm x10cm x 10cm • Electric field of 60kV/10cm • 10-9mbar (1) • Picture Setup@GSI, T. Giacomini

  8. NPM – Ionisation Profile Monitor SPACE CHARGE EFFECT With the 60kV/10cm, the ion deviation of 10% for a 1 GeV beam of 2mm diameter • Other options • Increase the electric field • Use an additional magnetic field 5cm ∆ (1) • Picture Setup@GSI, T. Giacomini

  9. NPM RADATION HARDNESS • Decision of components depend of their liftime : • Viewport • Luminescence screen • Camera, PMT (1) • Picture Setup@GSI, T. Giacomini

  10. Thank you for your attention