1 / 17

DETECTORES DE RADIACION

DETECTORES DE RADIACION. Dr. AMADO MENDEZ. CATEGORIAS 1.DETECTORES PARA MONITOREO PERSONAL 2.DETECTORES PARA REGISTRIO AMBIENTAL DOSIMETROS PERSONALESñ CAMARAS DE IONIZACION METODO DE OPERACIÓN

vanna-eaton
Download Presentation

DETECTORES DE RADIACION

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DETECTORES DE RADIACION Dr. AMADO MENDEZ

  2. CATEGORIAS 1.DETECTORES PARA MONITOREO PERSONAL 2.DETECTORES PARA REGISTRIO AMBIENTAL DOSIMETROS PERSONALESñ CAMARAS DE IONIZACION METODO DE OPERACIÓN Consisten basicamente de dos electrodos : POSITIVO central o interno debidamente aisaldo y uno externo NEGATIVO,. Esta camara debera ser cargada antes de usarse. LA RADIACION IONIZANTE INTERACTUA CON EL AIRE O LAS PAREDES DE LA CAMARA PARA FORMAR IONES POSITIVOS Y ELECTRONES NEGATIVOS SIEN DO QUE LOS ELECTRONES MIGRAN HACIA EK ELECTRODO CENTRAL DE ESTA FORMA EL NUMERO DE IONES POS ITIVOS SE REDUCIRA EN EL ELECTRODO CEN TRAL SEGÚN LA CANTIDAD DE RADIACION IONIZANTE PENTRANTE.

  3. CUANDO EL DE IONES POSIITIVOS DEL ELECTRODO CENETRAL SE REDUCEN LA CARGA SE REDUCIRA TAMBEIN INDICANDO QUE LA FUERZA REPELENTE ENTRE LA BANDA NOVIL DEL ANODO Y LA PORCION ESTACIONARIA TAMBIEN SE HA RE DUCIOO Y EL RESULTADO NETO SERA QUE LA BANDA MOVIL SE COLOCARA MAS CERCA A LA PORCION ESTACIONARIA. ES POSIBLE CALIBRAR LA CAMARA EN UNA ESCALA VISIBLE LA DISTANCIA DE LA BANDA MOVIL DE LA PARTE ESTACIONARIA DEL ELECTRODO CENTRAL, Y SU RELACION CON UNA EXPOSICION. LECTURA ANOTE EL VALOR INICIAL DEL DIA Y EL VALOR FINAL LA DIFERENCIA SERA LA EXPOSICION INTEGRADA RECIBIDA POR EL DOSIMETRO.

  4. FILM BADGES O DOSIMETROS DE PELCIULA LA DENSIDAD DEL FILM DESPUES DE LA EXPOSICION A LA RADIACION X SERA DE PENDIENTE NO SOLO DE LA CANTIDAD DE RADIACION RECIBIDA SINO ADEMAS A LA ENERGIA DE LA RADIACION FILTROS FILTER –FILM-DENSITY-RATIO Y CURVAS DENSITOMETRICAS CARACTERISTICAS

  5. D E N S I M E T R O CURVA DENSITOMETRICA

  6. DOSIMETRIA POR TERMOLUMINISCENCIA DOSIMETROS TERMOLUMINISCENTES

  7. LECTOR TERMOLUMINISCENCIA

  8. CONSISTE DE CRISTALES QUE RESULTAN PRODUCIDOS DESPUES DE LA EXPOSI CION A LA RADIACION IONIZANTE . LOS CRISTALES MAS USADOS SON FLUORURO DE LITIO , FLUORURO CALCIO MANGANESO AL EXPONERSE TLD CRYSTAL A RADIACION CONOCIDA Y CALIENTA EL CRISTAL SE EMITIRA UNA CANTIDAD DE LUZ MEDIBLE POR EL LECTOR ESTA LUZ SERA DIRECTAMENTE PROPORCIONAL LA RADIACION RECIBIDA SE DEBE CALIBRAR LUZ EMITIDA VERSUS RADIACION.

  9. DETECTORES DE CAMPO

  10. G R A C I A S

More Related