Propylene Oxide Production by ARCO Process. Done By Fiasal Juhail. Out Line:. Distillation column Reactor Pump Separator. 1.Distillation ColumnT-(100): Objective : To separate TBA from TBHP to fed it to the second reactor. Assumptions 1-Tray spacing= 0.6 m

Download Presentation

Propylene Oxide Production by ARCO Process

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Propylene Oxide Production by ARCO Process Done By Fiasal Juhail

  2. Out Line: • Distillation column • Reactor • Pump • Separator

  3. 1.Distillation ColumnT-(100): • Objective : • To separate TBA from TBHP to fed it to the second reactor.

  4. Assumptions • 1-Tray spacing= 0.6 m • 2-Percent of flooding at maximum flow rate=85% • 3- Percent of downcomer area of total area=12% • 4- The hole area =10% the active area. • 5-weir height=50 mm • 6-Hole diameter=5 mm • 7-Plate thickness=5 mm

  5. Design Procedure 1. Collect the system physical properties. 2. Calculate liquid - vapor flow factor. = vapor mass flow rate, Kg/s = liquid mass flow rate, Kg/s = vapor density, Kg/m3 = liquid density, Kg/m3

  6. 3-Select trial plate spacing from 0.15m to 1m. 4. Calculate the net area required. = volumetric flow rate, m3/s = flooding at maximum flow rate, m/s

  7. 5. Calculate total column cross sectional area. 6. Calculate the column diameter.

  8. 7. Calculate number of holes. Where = cross sectional area of downcomer , m2 Where = net area, m2

  9. Where = active area, m2 Where Area of one hole = = hole area, m2 Number of holes = Ah / area of one hole

  10. 8. Calculate height of the column. 9. Calculate thickness of the column. Where = column thickness, in = maximum pressure, psi = column radius, in = stress of metal, psi S = joint efficiency

  11. 10. Select the material of construction. 11. Select the material of insulation. 12. Estimate the cost of the equipment.

  12. Centrifugal Pump Centrifugal pumps are essentially a type of enclosed pump in which a liquid is drawn in and delivered in a continuous stream by the rotation of a fan.

  13. Assume: ή = 75% • The head of the pump (H) = Where: • H= the static head of the pump in m. • ρ= the density of the fluid kg/m3 • Break horse power (BHP) • Where, • BHP =is the break horsepower of the pump in watt • Q= flow rate in m3/s • H= the static head of the pump in m. • ρ= the density of the fluid kg/m3 • Calculate the discharge diameter of the pipe (D)

  14. horse power(HP): Calculate the discharge diameter using the following equation: • Where, • ∆P is the pressure difference between the inlet and outlet streams in kpa • G: flow rate kg/s • ρ: the density of the fluid kg/m3 • μ: viscosity cp • D: pipe diameter mm

  15. Equipment Name Pump (2) Objective To increase pressure Equipment Number P-100 Type Centrifugal Pump Material of Construction Carbon steel Insulation Quartz wool or Glass wool Cost 3900 $ Inlet Temp. (oC) 53.06 Outlet Temp. (oC) 53.22 Inlet Press. (psia) 67 Outlet Pres. (psia) 101.5 Efficiency (%) 75 H Power 9.4

  16. Reactor CRV 100 : It is a CSTR Reactor Which convert i-butane Into TBA and TBHP. • Oxidization of i-butane by O2

  17. Procedure Design: • To calculate volume of reactor: • V=(Fao-Fa)/-ra = (Fao-Fa)/kCao(1-X) • Assume H/D = 4 • V = 3.14/4 * D^2 • FA0=Molar flow rate • .-rA =Reaction rate. • FA=Molar flow rate of outlet • X=Conversion. • K= Constant of rate of reaction • CA0= Entering concentration. • H = Height of reactor • D = Diameter of reactor • V = Volume of the reactor.

  18. Separator Design • Objectives: -To separate vapor gases from the liquid

  19. Design Procedure • 1) Calculate the settling velocity. • 2) Calculate vapor volumetric flow rate. • 3) Calculate liquid volumetric flow rate. • 4) Determine the volume held in vessel using the above information's. • 5) Then calculate the minimum vessel diameter. • 6) Calculate the liquid depth. • 7) Determine the thickness of the wall. • 8) Calculate the length of the vessel. • 9) Then calculate the volume of metal using the difference between volumes using inside and outlet diameters. • 10) Calculate the weight of the metal. • 11) Calculate the cost.

  20. Correlations Used in Design Settling velocity: • Where: • Ut=Settling velocity (m/s) • ρL= density of liquid • ρV; density of vapor

  21. - Calculate vapor volumetric flowrate. - Calculate liquid volumetric flowrate. - Determine the volume held in vessel using the above information's. - Then calculate the minimum vessel diameter.

  22. Liquid Depth (HV): Length (h) : • - Surface area of the vessel: (2*pi*(Dv/2)*h)

  23. - Determine the thickness of the wall. • Where: • TH: thickness (in) • P: internal pressure (psig) • RI: internal radius of shell (in) • Ej: efficiency • S: working stress (psi) =13700 for Carbon Steel • Cc: allowance for corrosion (in)

  24. Volume of metal: Weight of metal: