An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Radiation Center Budapest Szilvia Varga-Fogarasi Hungarian Meteorological Service Surface Observations Division fogarasi.sz@met.hu

  2. Measurements - global • Global radiation and UV: CM 11 pyranometer Robertson-Berger UV-Biometer

  3. Measurements - global • 34 stations in the country • type: CM-11 • calibrated in every 2 years (with replacement) • daily routine check on the data and the state of the network

  4. Measurements - global

  5. Measurements - spectral Brewer MKIII No 152

  6. Measurements - spectral (Brewer) LI-1800 (equipped with a tube) (mounted on a sun-tracker)

  7. Measurements – else Data logger: Campbell CR3000

  8. Measurements – else

  9. Activity as a Regional Center HF 19746 Eppley Absolute Pirheliometer Kipp@Zonen CH 1B Pirheliometer Kipp@Zonen CH 1A Pirheliometer Controlling system

  10. Activity as a Regional Center

  11. Activity as a Regional Center 1984 – Pyranometer comparison • Purpose: possible and expectable devations between the pyranometers operating in different countries • Norway, UK, Switzerland, Poland, Hungary, GDR, FRG, Turkey, Austria • Results published by the WMO (Instruments and observing methods report No 16)

  12. Activity as a Regional Center • 1997 – pyrheliometer comparison • participating countries: • Austria, Czech Republic, Slovakia, Poland, Hungary • Decreased interest for regional pyrheliometer comparison (it is solved in Davos) • New idea is welcome for extensing the activity as an RC

  13. A possibility • Comparison of pyranometers? • Field intercomparison was recently organised by Croatia for our region • Comparison of calibration methods? • A possible reality: comparison of pyrgeometers

  14. EPPLEY PIR radiometer Calibrated and modifyed in Davos CGR 4 pyrgeometer secondary standard Our standard pyrgeometers LW network – project-oriantated

  15. Thank you for your attention For further information don’t hesitate to contact me or Mr. Zoltán Nagy (head of Surface Observations Division,nagy.z@met.hu)