1 / 25

Integration Envelope inside the TPC INNER FIELD CAGE for new detectors

Integration Envelope inside the TPC INNER FIELD CAGE for new detectors. John A. Scheblein Sr. Design Engineer STAR Technical Support Group May 16, 2008 B.N.L. Bldg. 1006C. PREVIOUS SVT/SSD INSTALLATION. Quarter Section Interface Envelope. Drawing number SIM140 Rev “J”

verity
Download Presentation

Integration Envelope inside the TPC INNER FIELD CAGE for new detectors

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Integration Envelope inside theTPC INNER FIELD CAGEfor new detectors John A. Scheblein Sr. Design Engineer STAR Technical Support Group May 16, 2008 B.N.L. Bldg. 1006C

  2. PREVIOUS SVT/SSD INSTALLATION

  3. Quarter Section Interface Envelope • Drawing number SIM140 Rev “J” • Shown with the SSD & SVT

  4. SIM140J

  5. Quarter Section Interface Envelopefor new detectors • Drawing number SIM140 Rev “K” • Shown without the SSD & SVT • First draft for new detectors integration • Will use the same procedure as L.B.N.L. to assign real estate

  6. SIM140K

  7. EAST SVT/SUPPORT DRAWING • Drawing number SIM181 Rev “E” • Will use this as the new detector integration drawing

  8. East SIM181E SVT/SUPPORT ENVELOPE

  9. EAST FTPC ENVELOPE DRAWING • Drawing number SIM212 Rev “B” • Shown with SVT • Will be used when the FTPC is replaced

  10. East SIM212B FTPC ENVELOPE

  11. Cone Assembly

  12. I.R. REGION BETWEEN BEAMPIPE SUPPORTS

  13. SSD There are no SIM drawings of the SSD envelope

  14. Drawing numbering system • Suggest each institution use their own numbering and revision system. • Use a 4 character prefix. (BEMC, FTPC, etc.) • Let me know what prefix you decide to use for your subsystem. • Do not want to cross reference institution drawing number to STAR drawing numbering system that was done in the past. • How many new subsystems will be added? • Please keep me in the loop during the design.

  15. Final drawings • All drawings to be done using ANSI Y14.5 and standard drafting practices • When job is completed each institution will deliver an electronic drawing list and the model & part files to BNL Star Technical Support Group • Preferred recommended formats: • Autodesk Inventor • Autodesk Autocad • Solidworks • DXF (minimum for 2-D) • Do have Pro-Engineer #M110 (11/8/07) Have not loaded it and do not have maintenance • Must have documented files sent to STSG

  16. Please do not install any equipment into STAR without providing documentation to the STAR Technical Support Group • Sketches • Manufacturing drawings • Solid models • Photographs • Specifications • Have the drawings reflect the parts installed.

  17. Some Photographs

  18. Cone

  19. BEAMPIPE SUPPORT

  20. Why do we need accurate and up to date drawings of equipment installed into STAR? Because……

  21. Resistor Chain……. Where is the documentation on this?

  22. Another Resistor Chain……. Where is the documentation on this?

  23. Resistor Chain documentation……. Where is the drawing for this resistor chain?

  24. Questions? thank you

  25. John Scheblein(631) 344 - 2654schebs@bnl.gov

More Related