330 likes | 592 Views
TYPE 23 POWER & DISTRIBUTION PO COLES. NOTE. The full presentation covers high voltage systems, switchboards, 600, 440, 115 volt systems, services and Essential Services, the P&D system. This was used to develop and teach technicians And the electrical damage control teams who
E N D
TYPE 23 POWER & DISTRIBUTION PO COLES
NOTE The full presentation covers high voltage systems, switchboards, 600, 440, 115 volt systems, services and Essential Services, the P&D system. This was used to develop and teach technicians And the electrical damage control teams who would also have to attend my electrical workshops For CPD. All system content has been removed.
Aims • To develop our understanding of the Type 23 Electrical Power System and develop the P&D model: • Covering: • The basic components of Generators. • How 450/600v Switchboards and ACBs operate. • 440v services through EDC’s and MCCB’s. • Distribution via Fuse Panels and Transformers. • Freestanding ROCOS.
Generator • Content Removed
Generator Main Rotor & 3Ø Output Stator PMG – AVR Supply Pilot Exciter Rotor Main Bearing
Generator Main Rotor & 3Ø Output Stator PMG – AVR Supply Pilot Exciter Rotor AVR Control Main Bearing Main Exciter Rotor Armature & Stator
Generator Main Rotor & 3Ø Output Stator PMG – AVR Supply Pilot Exciter Rotor AVR Control Main Bearing Main Exciter Rotor Armature & Stator AC to DC Rotating Rectifier
Generator 3Ø Output AVR Feedback Main Rotor & 3Ø Output Stator PMG – AVR Supply Pilot Exciter Rotor AVR Control Main Bearing Main Exciter Rotor Armature & Stator AC to DC Rotating Rectifier
Generator 3Ø 61.2Hz 600v Pilot Exciter Main Exciter Rotating Rectifier 16 poles 24 poles 8perØ Stator PMG Stator (99 Slots) Main Generator AC Full Wave rectified to DC 77v 29A 160Hz AC 49.5v 197A DC Output AVR Feedback Signal
Novamax ACB’s • Content Removed • Spring Charging (Motor) • Manual Ratchet & Pawl • Solid State Trip Unit • Shock Protection • 0.8 Power Factor lag
Novamax ACB’s OXO Cube (Indicates I1/I2 Trip) Spring Charged (White Discharged) Breaker Status (Logic Indicator) Charging Handle (Moves Crank) Close ACB Open ACB
Novamax ACB’s (B) (A) (C) (E) (F)
Novamax ACB’s (A) (B)
Novamax ACB’s Battery Check & Charge (red LED illuminates) Battery Module I3 – Instantaneous Over Current Trip Indication (Switches Orange when tripped) I2 – Short Time Over Current I1 – Long Time Over Current I1,I2 Reset
Novamax ACB’s Easy Access Fuses Control Cables Cables (from MEPS)
Novamax ACB’s (1) (3) (2) (4)
Switchboard Common 600v Rail
Switchboard 600v from Generators Common 600v Rail 600v Services
DG F2 600v Switchboard DG F2 600v Common 600v Rail
DG F2 600v Switchboard DG F2 600v Common 600v Rail EMACB 600v MGF Supply
MG Sets • Content Removed
Switchboard 450v 600v
Switchboard 450v 600v
Switchboard SS MG-F F1 Alt F1 F2 450v 600v I/C MG-F EMACB I/C
MCCB’s • 2 Types - 100A or 250A • 440V 60Hz 3Ø • Content Removed
MCCB’s • 250A MCCB’s fitted in Switchboards to supply EDC’s
Summary • Developed our understanding of the Type 23 Electrical Power System and developed the P&D model: • Covering: • The basic components of Generators. • How 450/600v Switchboards and ACBs operate. • 440v services through EDC’s and MCCB’s. • Distribution via Fuse Panels and Transformers. • Freestanding ROCOS.
Any Questions?