An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Oxidation Effects on the Optical Constants of Heavy Metals in the Extreme Ultraviolet Amy Grigg R. Steven Turley Brigham Young University

  2. Why Extreme Ultraviolet? Thin Film or Multilayer Mirrors EUV Lithography Soft X-Ray Microscope Earth’s Magnetosphere in the EUV

  3. Oxidation Problem • High absorption requires thin films. • The surfaces of many materials oxidize. • At optical wavelengths, this oxidation is often negligible. It is a major issue for our thin films, however.

  4. X-Ray Photoelectron Spectroscopy

  5. How XPS works

  6. Th 4f5/2 4f7/2 Th O 4d3/2 4d5/2 1s Th C 5d3/2 5d5/2 1s Electron Binding Energy

  7. Peak Shifts • Thorium peaks on surface • Thorium peaks after oxygen is gone

  8. Depth Profiling: Method 1 • Sputtering: Argon ions knock off individual atoms and drill a hole through the sample

  9. Analyzer X-ray Source e- θ e- e- Sample Depth Profiling: Method 2 • Variable angle scans: Depth is obtained as the analyzer is moved towards incidence

  10. Variable Angle Results • Only penetrates about 80 Angstroms into the sample • This allows us to see surface contamination, but not composition with depth • Results are averaged: cannot obtain resolved composition with depth

  11. Sputtering Results

  12. Results • This isn’t the true interface because the probability of electron escape is exponential with depth • Ideal interface:

  13. Results • Si interface is not ideal • This is likely due to the sputtering process • Implantation • Sputtering roughness • Shape of sputtered area

  14. Too Much Oxidation • These samples were only a few hours old. • We need more uniformity for single-layer reflectors. • Solution: Make ThO2 mirrors. Reflection is also high in EUV and it should be more uniform.

  15. ThO2 Results

  16. ThO2 Conclusions • Fully oxidized thorium is much more uniform. • ThO2 shows definite promise as a single-layer reflector in the EUV.

  17. Ultimate Goal • Determine the optical constants of our materials

  18. Fitting Reflection/Transmission • Others have taken the oxide layer into account, but have assumed an ideal interface • Measured oxidation (XPS) shows that our approximation is inaccurate

  19. Put the Data to Use • Incorporate what we know about oxidation into the way we determine our optical constants. • Write a data-fitting program Inputs: measured oxidation, reflection/transmission data Outputs: optical constants of measured element (δ and β)

  20. Data-Fitting Program • Task: Find the most likely optical constants (δ and β) to have produced the measured data that is input • Least squares routine: Minimize

  21. Function • Function f uses Matrix Method with Fresnel coefficients to determine theoretical reflection and transmission

  22. Fit and Data

  23. Continued Research • Make a sample, measure it with XPS, model the oxide layer with the program based on the XPS results, and test method • Make user interface for program if method works well • Determine cause of non-ideal Si interface

  24. Acknowledgements A special thanks to R. Steven Turley David Allred Matt Linford BYU Thin Films Group Physics & Astronomy Department Funding ORCA Mentoring Grant NASA Space Grant Images from www.schott.com/magazine/english/info99/ and www.lbl.gov/Science-Articles/Archive/xray-inside-cells.html.

  25. Other Results of Interest • There was an increase in oxygen when the sample sat for more than 4 or 5 minutes in between sputtering/scans. • This was observed for 5 out of 5 samples that sat still between scans.

  26. * * * * * indicates where the sample stood for more than 4 or 5 minutes in between scans

  27. What Could This Be? • Hypothesis: This is likely due to preferential sputtering. • The argon ions will knock off oxygen atoms more readily than thorium. • While sputtering, scans would show less O than actually exists.

  28. Future Research • Test preferential sputtering hypothesis. • Investigate other peak anomalies: N, Ar