190 likes | 291 Views
Reference Monitoring @ Q-Cells. Intersolar 2011. CONTENT. 1. NETWORK OF REFERENCES UNDER MONITORING 2. EXAMPLES OF PERFORMANCE DATA 3. LIVE LOG-IN TO WEB PORTAL. 2. Network of References under Monitoring (1). Why reference monitoring? In reality, STC conditions almost never occur…
E N D
Reference Monitoring @ Q-Cells Intersolar 2011
CONTENT 1. NETWORK OF REFERENCES UNDER MONITORING 2. EXAMPLES OF PERFORMANCE DATA 3. LIVE LOG-IN TO WEB PORTAL 2
Network of References under Monitoring (1) • Why reference monitoring?In reality, STC conditions almost never occur… • Crucial is the performance under real conditions, in different applications and segements! • Monitoring and development of Q-Cells products under real conditions (ex. Anti PID-Technology) 3
Network of References under Monitoring (2) • Why reference monitoring? • Benefits for you: • Improved performance calculations due to energy yield simulation under real life conditions • Optimisation of system design and installation based on real performance data • Broad reference data base for installation benchmarking 4
Worldwide Reference Network under Monitoring • Currently about 68 reference sites under monitoring • Covering nearly all climate conditions, applications, and segments We need you to further build up the worldwide network! 5
CONTENT 1. NETWORK OF REFERENCES UNDER MONITORING 2. EXAMPLES OF PERFORMANCE DATA 3. LIVE LOG-IN TO WEB PORTAL 6
REFERENCE UNDER MONITORING Project: Straßkirchen Location: Bavaria, Germany Power: 51 MWp Orientation: South Inclination: 25° Installation: December 2009 Segment: Utility Application: Field installation Performance Ratio*: 86% Simulated PR**: 81,6% * Period: 2010; ** independent certified engineering service (yield certificate)
REFERENCE UNDER MONITORING Project: Potsdam Location: Brandenburg, Germany Power: 8.46 kWp Orientation: South Inclination: 30° Installation: 2010 Segment: Residential Application: Rooftop Performance Ratio*: 86% *Period: May 18 – May 31 2011
Überwachte Referenzanlage REFERENCE UNDER MONITORING Project: Delitzsch Location: Saxony, Germany Power: 5,4 kWp Orientation: South Inclination: 40° Installation: March 2010 Segment: Residential Application: Rooftop Performance Ratio*: 86% Special Energy Yield*: 1049 kWh/kWp Simulated PR**: 86,8% Simulated Yield**: 1004 kWh/kWp * Period: March 2010 – February 2011, **PV*SOL Simulation with Application Note 9
REFERENCE UNDER MONITORING Project: Schackenthal Location: Saxony Anhalt, GermanyPower: 30,34 kWp Orientation: South-South-East Inclination: 14° Installation: March 2010 Segment: C&I Application: Flatroof Performance Ratio*: 85% Specific Energy Yield*: > 903 kWh/kWp Simulated PR**: 87,5% Simulated Car**: 951 kWh/kWp * Period: March 29th 2010 – March 28th 2011, **PV*SOL Simulation with Application Note
Best performance under extreme conditions REFERENCE UNDER MONITORING Project: Alice Springs Location: Alice Springs, Australa Power: 5,61 kWp Orientation: North Inclination: 20° Segment: Utility (test site) Weblink: http://www.dkasolarcentre.com.au/
CONTENT 1. NETWORK OF REFERENCES UNDER MONITORING 2. EXAMPLES OF PERFORMANCE DATA 3. LIVE LOG-IN TO WEB PORTAL 12
Live Login to Web Portal Q.PRO example system Login-Data: www.q-cells.com/monitoring Username: qcells_intersolar_deu qcells_intersolar_eng Password: 2011intersolar Q.SMART example system Temporary login to web portal for intersolar guests 13
REFERENCES UNDER MONITORING Monitoring Components Irradiance cell (in module plane) Module temperature sensor Data logger Energy counter Inverter interface Ambient temperature sensor WAN/GSM Analogue signals Digital Signal (S0) www Bus (RS485) Database Web server / Portal 15
References under Monitoring – Indicators • SPECIFIC ENERGY YIELD [kWh / kWp] • Energy feed into grid normalized to installed nominal (STC) module power • PERFORMANCE RATIO [%] • Irradiance sensor is needed to calculate PR! • Describes, how efficient the incoming irradiance energy is used • Performance Ratio = 100%: The entire system runs with nominal module efficiency 16
Überwachung von Referenzanlagen – Kennzahlen • Loss factors: Inverter efficiency, wiring, low light behavior, temperature and shading • Common knowledge, annual PR > 80%: “Good” value 17
REFERENCE UNDER MONITORING Project: Steutz Location: Saxony Anhalt, Germany Power: 22,05 kWp Orientation: South Inclination: 32° IInstallation: March 2010 Segment: C&I Application: Rooftop Performance Ratio*: 87% Special Energy Yield*: 1041 kWh/kWp Simulated PR**: 86% Simulated Yield**: 994 kWh/kWp * Period: March, 18th 2010 – March, 17th 2011, **PV*SOL Simulation with Application Note
Überwachte Referenzanlage REFERENCE UNDER MONITORING Project: Solibro Facade Location: Saxony Anhalt, Germany Power: 17 kWp Orientation: South Inclination: 90° Installation: June 2008 Segment: C&I Application: BIPV Performance Ratio*: 84% Special Energy Yield*: 705 kWh/kWp * Period: 2010 19