An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. HQ Status report on the mechanical analysis H. Felice – P. Ferracin

  2. 2 apertures are considered within the range proposed by CERN: • 134 mm • 114 mm • The comparison will be made at Short Sample gradient with a LQ based mechanical structure • 134 mm => ~ 200 T/m • 110 / 114 mm => ~ 235 T/m • Still in the magnetic design optimization => 1 cross-section of each aperture has been picked 134 mm 110 mm Courtesy of Vadim Kashikhin

  3. Mechanical analysis LQ-based structure 622 mm = overall diameter 20 mm iron master Courtesy of Vadim Kashikhin • Short Sample Gradient ~ 200 T/m • Bladder operation : 55 mm bladder pressurized at 50 MPa Ti poles 25 mm Al pad 97 mm iron yoke 40 mm Al shell

  4. Azimuthal stress in the coil 134 mm aperture Bladder operation Cool-down At 200 T/m Contact pole/coil At 200 T/m

  5. Azimuthal stress in the coil 110 mm aperture – Same mechanical structure Bladder operation Cool-down At 235 T/m At 235 T/m Contact pole/coil Requires optimization (key location, bladder size, parts thickness)