An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2006 New Products SPLIT Wall Mounted Type FTXR-E series Heat Pump Ver. 1.00 DAIKIN Global Operations Division

  2. — Concept — DAIKIN’s original NEW air conditioner with Humidity control. The first technology in the industry. Product Concept Ururu ... Humidifying Operation creates humid air Sarara ... Re-heater Dehumidifying Operation creates fresh air

  3. — Features — Humidity ControlNo Water Supply Humidifying OperationRe-heater Dehumidifying Operation Ventilation & Air-purifyingAir Supply VentilationFlash Streamer Air-purifyingMold Shock Operation Energy SavingAll "A" EER Label Comfortable AirflowComfortable Airflow Mode < Indoor Unit > FTXR28/42/50EV1B Features < Outdoor Unit > RXR28/42/50EV1B

  4. — Heat Pump — Product Line Up

  5. — Function List — (Function name is tentative.) Functions

  6. — Humidifying Operation — Outdoor unit Daikin’s original technology “No water supply humidifying” Control not only temperature in a room but humidity. As moisture is absorbed from the outdoor air, humidification is possible even in the drier air of winter. It also means that you do not have to refill the water supply for the unit. Humidity Control Moisture is extracted from the Outdoor air. What’s good about humidifying Humidified air creates a feeling of warmth and It prevents from getting too warm. Moderate humidification and a relatively low set temperature will leave you feeling warmer. Gentle to your skin This function keep moderate humidification in a room, and treats your skin kindly. It effects well in a winter when your skin easily gets dry.

  7. — Effect of Humidifying — Humidification by air conditioner provides your room with moisture evenly as compared to a single humidifier. Humidity Control Rather dry in lower space With a humidifier alone, humidified air stagnates in the upper part of the room. With heating plus humidifying Your room is filled with humidified air evenly throughout the room.

  8. Chilly — Effect of Humidifying — You feel warmer in a humidified air even at a lower temperature. warm Humidity Control Room temp.: 28°C Humidity: 20% You feel cold in a dry air even at a higher temperature. Room temp.: 22°C Humidity: 50% You feel comparatively warmer in humidified air. The thermograph shows the temperature distribution of the skin 30 min. after entry into the room. 30.0 35.0 40.0°C

  9. — Effect of Humidifying — Heating plus humidifying operation keeps moderate humidity for your skin. Moreover “Moisturizing operation” gives you more moisture to protect your skin from dryness due to heating. Humidity Control < Only heating > < Heating & humidifying > Adequately moisturized skin Surface of dry skin exposed to dry air - You feel free from dryness of skin - Skin is well conditioned.

  10. —Humidifying mechanism— The humidifying rotor absorb moisture from the outdoor air which has been sent to the humidifying unit. The moisture is supplied to the room through the humidifying hose. Humidity Control Humidifying heater Humidifying rotor Humidifying unit To humidifying hose Humidifying hose

  11. —Humidifying mechanism— 1.Absorbs moisture from the outdoor air Even dry air in winter contains moisture. The humidifying rotor absorbs moisture from the outdoor air taken into the humidity absorption section by the humidifying fan. 2.Sends moisture The humidifying rotor rotates to send the absorbed moisture to the moisture emission section. Humidity Control Humidifying rotor Humidifying fan 1.Absorbs moisture Humidity absorb section 2.Rotates humidifying rotor

  12. —Humidifying mechanism— 3. Emits moisture In moisture emission section, the absorbed moisture is emitted by heating humidifying rotor up. The moisture is mixed with the outdoor air to make highly humidified air. 4. Sends the moisture to the room The emitted moisture is sent to the humidifying hose by the ventilation fan to be supplied to the room. Humidity Control 3.Heats up the rotor Ventilation fan 4. To the room via the humidifying hose Moisture emission section

  13. With Re-heater dehumidifying — Re-heater dehumidifying — Refreshing without lowering the room temperature Humidity Control Especially for rainy season Outdoor temp.: 22°C Humidity: 90% Refreshing and comfortable In the case ofRe-heater dehumidifying In the case of conventional dry operation You feel cold Room temp.: 19°C Humidity:50% You feel chilly because of dehumidifying by lowering room temperature. Room temp.: 22°C Humidity:50% You feel comfortable because of dehumidifying without lowering room temperature.

  14. — Effect of Re-heater dehumidifying — Lower humidity creates comfortable condition even at the same temperature. Refreshing and comfortable Humidity Control Muggy Room temp.: 25°C Humidity:80% You feel stuffy with high humidity. Room temp.: 25°C Humidity:50% You feel comfortable at the same temperature with lower humidity. The thermograph shows the temperature distribution of the skin 30 min. after entry into the room. 30.0 35.0 40.0°C

  15. —Re-heater dehumidifying mechanism— Re-heater Heat exchanger Damp air Re-heater Dehumidifying Operation 1.Cooling and dehumidifying the air extracted by cooler. 2.Heating up the extracted air by re-heater. 3. The dehumidified cool air (1) is mixed with the re-heated air (2) to be proper condition before sent to the room. Humidity Control Air warmedby re-heater (1) Cooler Dry and cold air (2) Dry but not cold air (3)

  16. Outdoor unit Indoor unit open close Electronic expansion valve Heat exchanger Heat exchanger Compressor Solenoid valve for dehumidifying —Re-heater dehumidifying mechanism — Puts a pressure reducing device (solenoid valve) in the center of the heat exchanger of indoor unit to separate it into upper and lower side. The upper side acts as a condenser to reheat the discharged air. Humidity Control Outdoor unit Indoor unit <The current DRY operation> As is the cooling mechanism, the current DRY operation rises latent heat capacity with controlling sensible heat capacity by adjusting the compressor frequency and indoor air flow rate. close* open Comp. * Depends on the condition

  17. - Temperature control and air intake Air supply filter - Filters out pollens and dust + Humidifyingrotor Thermal catalyst - Elimination of exhaust gases (NOx / SOx) Indoor Unit Photocatalytic air purifying filter - Decomposition of bad smells - Decomposes odors which can not be filtered out. Fresh and clean air Bad smells and pollens Flash Streamer Outdoor Unit formaldehyde, virus, mold fungus Draft Outdoor air Indoor Outdoor Shut out odors and dusts in the draft — Air Supply Ventilation — Contaminated outdoor air is purified through 2 stages of the outdoor unit and indoor unit. Ventilation

  18. Fresh air Airsupply — Air Supply Ventilation — Powerful (32 m3/h at “High”) ventilation by unique air supply system! Ventilation The air in a 26m2room is replaced with “Fresh air” in 2 hours.

  19. — Internal Dry (Damp Discharging) — Dehydrates the inside of the indoor unit to inhibit the generation of mold and odor. This operation continues for about 3 hours after the cooling operation is stopped. Ventilation <1. Draining> Water accumulated in the drain pan is drained. <2. Internal dry> After draining water, water drops left in the drain pan and heat exchanger are evaporated and dehydrated by heating inside of the indoor unit. <3. Discharge of damp > The damp is discharged to outdoor through the humidifying hose. The damp (evaporated by internal dry) is discharged to outdoor in the form of vapor. Since the sources of mold are discharged to outdoor, the inside of the indoor unit is kept always clean!

  20. — Technology — About air supply & exhaust functions - Air supply and exhaust through the humidification hose - Controlling air supply and exhaust by the damper in the outdoor unit. Ventilation Ventilation fan Air supplyposition Ventilation fan Air exhaust position

  21. — Flash Streamer — Flash streamer improves air purify performance! Powerful air purifying with Flash streamer technology which has been adapted on the DAIKIN Air purifier. Air-purifying Flash Streamer Unit Flash Streamer Unit

  22. — Flash Streamer — Over 1000 times faster than plasma discharge! Air purify flow Streamer discharge gets 1000 times faster oxidize decompose speed than the most common type of plasma(glow) discharge does while using the same amount of electrical power. Air-purifying New air purify method with streamer Pre-filter Powerfully decompose and remove molecules of allergens or odors by collision with high-speed electrons discharged from streamer unit. Deodorizing filter Streamer discharge Terminal unit

  23. — Flash Streamer — Quick deodorizing Quickly remove ingredients of odor ●Removal rate of lifestyle related odor. (%) 100 Air-purifying Cigarette Pet Naturally removed 80 Persist rate(%) Over 90% removed in approximately 10 min. 60 Bathroom Mold 40 20 Fish Egg 0 5 10 15 Time (min.) Ammonia:Pet odor・Bathroom odor Trimethlamine:Fish odor Cooking Garbage Methyl Mercaptane:Garbage odor・Rot odor Hydrogen Sulfide:Egg odor ※Persist rate of odor ingredients in a box of 1m3, operating FTXR42E(Daikin result)

  24. — Mold Shock Operation — This function is to control the growth of mold by lowering the humidity quickly dehumidifying for 3 hours continuously. Air-purifying Shut out mold and mite from a room by a sudden fall of room humidity! Mechanism of Mold Shock Operation Growth image of mold Mold Shock start Mold In general, growth of mold can be controlled under the condition of below 60% in humidity. Mold Shock OFF The hypha lengthwhich a spore germinates Create an environment where mold can hardly grow by a sudden fall of room humidity! Mold spores is destroyed when reducing the room humidity by half and keep the conditions for 3 hours. Reported by Environment Biologic laboratory Prof. Keiko Abe at International Congress. Mold Shock ON Time

  25. — Energy Saving — All "A" EER Label Energy Saving

  26. — Technology — Reluctance DC Motor New swing compressor Rotor part Further energy-savings with improvement of motor and compression efficiency. Neodymium magnet:4 pieces to 6 pieces.Rotation of motor gets more smooth. Current New Energy Saving Swing Compressor Neodymium magnet Stator part Current New Heat transfer coil: Distributed roll Concentrated roll The heat loss is reduced. Adopted cylinder structure less liable to heat-transfer loss and deformation. Distributed roll Concentrated roll

  27. — Technology — Twisted the grille to make the air flow from outdoor unit fan smooth and lessen the air flow resistance. It resulted in further energy savings. Energy Saving Standard air outlet grille New twist grille Right side Left side Right side Left side Highly efficient with the less air flow resistance by twisting left and right side of the grille respectively to be parallel with air flow. Not efficient because of air flow resistance caused by horizontal grille.

  28. — Technology — Compact size : Depth 198mm(when it is not operating) Achieved high COP with Slide Opening System and Saw Edge Fan Energy Saving Not operating Slide Opening System Slide opening system of front panel maintains a enough volume of air inlet during operation. Operating Saw Edge Fan The indentation of the fan blade reduces the air flow resistance. Achieves both the operation sound decrease and the air flow increases.

  29. — Flap Control — Air flow control with 4 different motors. Conventional model New model a Comfortable Airflow b,c d a.Slide opening panel motor b.Horizontal flap motor 1 c.Horizontal flap motor 2 d.Vertical flap motor Two flaps move only horizontally. Two flaps move independently. <Two horizontal flaps are controlled independently> Upward Downward Closed Panel image during operation

  30. — Comfortable Mode — Realizing the fine and efficient air flow control by controlling two horizontal-flaps independently. Comfortable Airflow Cooling Current model New model Air flow is spread out! NOT spread out! Upward air flow without air flow loss. Heating Current model New model NOT spread out! Air flow is spread out! The warm air reaches the floor.

  31. 9m 5cm above the floor 24.5℃ 10m5cmabove the floor 23.6℃ — Long Distance Airflow (Heating) — 190 Comfortable Airflow 100 Height (cm) 5 100 200 300 400 500 600 700 800 900 1000 Distance (cm) <Test conditions> Outdoor temp.: 2°C R/C setting: 23°C, “Powerful” 30 min. later the operation is started.Test room:32.4m2Test model:FTXR40E Create comfort in large space such as large living room

  32. —Two-way communication remote controller— New remote controller can control various functions. The buttons of frequent use are placed on the surface of the controller cover. The others are under the cover. The two-way communication between the controller and the indoor unit enables the controller to display the present temperature and humidity. Easy Control Under the cover

  33. — Direct Mode Buttons — The operation modes used frequently, Cooling, Heating, Humidifying and Dehumidifying are assigned to each special button placed on the surface of the controller. You can set each mode by just one push. Easy OFF timer Easy Control Humidifying Automatic Operation Cooling Heating Dehumidifying

  34. — Temp. & Humidity Indication — I.D&O.D Temperature display  The present indoor and outdoor temperature is shown on a remote controller display when pushing the "info" button. It is economic if you change the set temperature appropriately according to the information. Easy Control After 10 sec. or one more push Humidity display  The indoor humidity is displayed by 5% on a remote controller when pushing the "info" button. By controlling humidity properly according to the information, you can prevent the growth of mold and mite. Onepush Indoor temperature and humidity display Outdoor temperature display

  35. — Other Functions — Variable Functions

  36. — Other Functions — Variable Functions

  37. — Other Functions — Variable Functions

  38. Specifications — Main Specifications — Power Supply: 50Hz 220-240V