1 / 18

Pipe Freeze Protection

Pipe Freeze Protection. XL-Trace Systems. Pipe Freeze Protection and Flow Maintenance. System Overview. Applications. Above or Underground Freeze Protection General Water Piping Sprinkler Piping Flow Maintenance Grease Disposal Lines Fuel Lines. Consequences of system failure.

wan
Download Presentation

Pipe Freeze Protection

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Pipe Freeze Protection

  2. XL-Trace Systems • Pipe Freeze Protection and Flow Maintenance

  3. System Overview

  4. Applications • Above or Underground • Freeze Protection • General Water Piping • Sprinkler Piping • Flow Maintenance • Grease Disposal Lines • Fuel Lines

  5. Consequences of system failure • Frozen or clogged pipes • Environmental hazard from spills • Equipment damage • Loss of production • Life-safety issues

  6. Determine Design Conditions

  7. Select Heating Cable Output

  8. Pipe Heat Tracing Heat Loss Ambient temperature Heating cable power output Pipe size (D) Insulation thickness Remember: Heating cable only maintains the temperature of stagnant fluid by replacing the heat lost through the thermal insulation

  9. Determine Voltage & Jacket • Select Heating Cable Voltage • Select Outer Jacket

  10. Determine Heating Cable Length

  11. Determine Heating Cable Length

  12. Select Temperature Controls • Manual control • Ambient thermostat • Line sensing thermostat • Solid-state Controller • Tie into BMS

  13. Controls DigiTrace 910 Solid-state Temperature Controller with Ground Fault Protection AMC-1A Ambient sensing Thermostat AMC-F5 Fixed 40°F setpoint Thermostat AMC-1B Line sensing Thermostat

  14. Determine Number of Circuits • Use the heating cable number to determine the maximum circuit length

  15. Calculate Transformer Load 16 • Use the total amount of heating cable and the maximum A/ft from table 7 to calculate the total transformer load.

  16. RayClic Components

  17. Product line - 6 connections • RayClic-PC Power Connection • RayClic-T Tee • RayClic-S Splice • RayClic-X Cross • RayClic-PS Powered Splice • RayClic-PT Powered Tee

  18. Accessories • GT-66 Glass tape • AT-180 Aluminum tape • ETL Warning labels (every 10’)

More Related