An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Installationand Startup For PrepGilsonST 1.2.62

  2. Introduction • This document describes the installation of the PrepGilsonST software, covering the following topics: • System requirements and compatibility. • Installation and configuration of the FlexLM license manager. • Installation of the program. • Startup of the program. For the specific configuration of the instrument check the tutorials for the appropriate application.

  3. Requirements • For PrepGilsonST the following minimum requirements have to be met: • Valid license ‘GILSON_PREP_1.0‘ • Administrator rights for the installation • Computer with an available ethernet adapter • 512MB RAM and 50MB of free disk space • Windows XP SP2 or Windows 2000 SP4 • At least one serial port for the Gilson instrumentCOM1..9 is recommended.Note, that COM ports supplied by an Ethernet server are not suitable.Note, that USB-RS232 (Bruker part number 80544) are suitable for most of the computers, but not recommended. • One additional serial port to use with a barcode reader.COM1..9 is recommended.

  4. Additional Requirements • Additional requirements depend on the application used (Summary) • SPE-TT: one additional free serial port(COM1..9), HyStar 3.1 or 3.2 installed on the same computer, LC-SPE system under control of HyStar. • 1mm Preparation: Suitable hardware for SampleJet Tubes. • Profiler Preparation: TopSpin 2.0, SampleTrack 2.57.49, HyStar 3.2.44,Compass SampleTrack communication 1.2.45, Perspex Cover • SampleTrack Preparation: SampleTrack 2.57.49.

  5. PrepGilsonST License • Login as administrator • If FlexLM is already running for other Bruker programs, proceed with special case #1. • If the Computer has two Ethernet adapters, continue with special case #2. • Install the FlexLM 9.2 program and accept the default settings. • Start the utility C:\flexlm\Bruker\lmtools.exe • On the tab System Settings identify • the Computer/Hostname • the Ethernet Address

  6. PrepGilsonST License Special Case #1 • FlexLM is already running with Bruker licenses (TopSpin) • To avoid confusion it is recommended to use the same „hostid“ for the PrepGilsonST program. • Open the file C:\flexlm\Bruker\licenses\license.dat. • Identify the hostid which is used for the other Bruker licenses. • Identify the computer name.

  7. PrepGilsonST License Special Case #2 • The computer has two Ethernet adapters and FlexLM has not yet been used. • In this case it is recommended you obtain the license for the additional/external Ethernet adapter. This enables a simple transfer of the license to another computer, should it be required. • Remove the Ethernet cable from the 2nd Ethernet adapter. • Do ‚Start/Run/Cmd‘ to enter a DOS- shell and run the command ‚ipconfig /all‘. • Identify the ‚Physical Address‘ of the adapter which shows ‚Media disconnected‘.

  8. PrepGilsonST License • With the Ethernet Address/Host Id/Physical Address detected above request a ‚GILSON_PREP_1.0‘ from from license@bruker.de from where you will receive a license in the following form (example) • FEATURE GILSON_PREP_1.0 bruker_ls 0.0 22-jun-2010 1 \ • BB6ED0914FAAF1705D24 vendor_info=" for hostid(s) : \ • 001018275491" ISSUER=0002b39766ed • If there is no ‘license.dat‘ file in C:\flexlm\Bruker\licenses\ then copy over the file C:\flexlm\Bruker\licenses\example_license.dat and rename as ‘license.dat‘. • Open your license.dat and add the above three lines at the end of the file. • For a copy of example_license.dat change the header to the determined values • If you had to copy example_license.dat then change the header to your previously determined values: ie. change ‚SERVER your_computer_name your_hostid 1700‘ to • ‚SERVER A09239785CAA434001018275491 1700‘ (as in this example)

  9. PrepGilsonST License • Restart the utilities fromC:\flexlm\Bruker\lmtools.exe • On the tab Service License File click(!)Bruker FLEXlm License Server • Then change to the tab Start/Stop/Reread and start the server and ReRead the license file. • After several seconds you will see the message: • Server Start Successfull

  10. PrepGilsonST License • Select the tab Config Services • Enable Start Server at Power Up and Use Services • Click Save Service

  11. Install PrepGilsonST • Login as administrator • If a previous version was installed, start it, open the configuration and note the COM ports used. • If the previous version of PrepGilsonST is <1.2.60 uninstall it. • Install PrepGilsonST Version 1.2.62 from the CD

  12. First Startup • Start the program PrepGilsonST in Start/Programs/PrepGilsonST • or from path C:\Program Files\Bruker\PrepGilsonST\bin\PrepGilsonST.exe • Select the desired application. If only one application is to be used, disable this dialog screen in the checkbox. • After the first startup the configuration dialog is automatically opened but you can always configure the system in the menu View/Configuration.

  13. Configuration • When you change the configuration the changes are applied immediately for the current application (i.e. the changes are stored in the configuration file). • Once you have configured your system it is recommended you create a backup copy of the current configuration in the menu File/Configuration save/load. • Note: Only one backup file is possible and the name is fixed by the current application (for example backup_SPE-TT.cfg) • This backup configuration can be restored from the same dialog. • Note: the current configuration in the foreground will be overwritten!