1 / 8

MAST Error Field Studies T C Hender, G Cunningham and D F Howell EURATOM/UKAEA Fusion Association

MAST Error Field Studies T C Hender, G Cunningham and D F Howell EURATOM/UKAEA Fusion Association Presented by G. Turri. 4 new Error Field Correction Coils installed on MAST. MAST Error Field Experiments. Intrinsic error. Constant Bt=-.55T, Ip=600kA. n e. 8. n e =2.0e19. 6. SXR. 4.

weston
Download Presentation

MAST Error Field Studies T C Hender, G Cunningham and D F Howell EURATOM/UKAEA Fusion Association

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. MAST Error Field Studies T C Hender, G Cunningham and D F Howell EURATOM/UKAEA Fusion Association Presented by G. Turri 4 new Error Field Correction Coils installed on MAST MHD Control workshop - Princeton - Nov 2004

  2. MHD Control workshop - Princeton - Nov 2004

  3. MAST Error Field Experiments Intrinsic error Constant Bt=-.55T, Ip=600kA ne 8 ne=2.0e19 6 SXR 4 2 EFC B current [kAt] 0 IEFCC -8 -6 -4 -2 0 2 4 6 8 -2 Da -4 -6 br -8 EFC A current [kAt] Circle radius = field for locked mode Lock time MHD Control workshop - Princeton - Nov 2004

  4. ne 30% lower Locked mode 0.0 0.1 0.2 0.3 0.4 time (s) Error Correction Extends Operating Space No EFCCs, optimal EFCCs Central SXR Ip IEFCC MHD Control workshop - Princeton - Nov 2004

  5. 4 Constant Bt=-0.55, Ip=600kA 3.5 3 2.5 [G] 2 21 B 1.5 1 0.5 0 0 1 2 3 4 5 19 -3 Line ave electron density [10 m ] Density Scaling JET IPB MAST 2.0E-04 F |/B 2,1 r n/nG=0.75higher li |B 1.0E-04 0.0E+00 0.0E+00 5.0E+18 1.0E+19 1.5E+19 2.0E+19 -3 n (m ) e *IPB, NF 1999 MHD Control workshop - Princeton - Nov 2004

  6. Toroidal Field Scaling 7 Bt=0.35 Constant Bt/Ip Bt=0.49 5 Bt=0.60 3 1 EFC B [kAt] -7 -5 -3 -1 1 3 5 7 -1 Need more points! -3 -5 -7 EFC A [kAt] MHD Control workshop - Princeton - Nov 2004

  7. q-Scaling 4 q95 qcyl 3 1.3601 y = 0.7573x [G] 2 21 B 1.1866 y = 0.1986x 1 0 0 2 4 6 8 q , q 95 cyl MHD Control workshop - Princeton - Nov 2004

  8. Conclusions • Error field limits density operation in MAST • New correction system recently installed, works properly • Measured threshold for locking • Error field correction extends operational space • Scaling seems to be consistent with other experiments MHD Control workshop - Princeton - Nov 2004

More Related