1 / 21

ACADs (08-006) Covered Keywords

Auxiliary Feedwater System. ACADs (08-006) Covered Keywords Components, functions, operation, Auxiliary feedwater , Startup, hot standby, plant cooldown , emergency. Description Supporting Material. Auxiliary Feedwater System. OBJECTIVES.

Download Presentation

ACADs (08-006) Covered Keywords

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Auxiliary Feedwater System ACADs (08-006) Covered Keywords Components, functions, operation, Auxiliary feedwater, Startup, hot standby, plant cooldown, emergency. Description Supporting Material

  2. Auxiliary Feedwater System

  3. OBJECTIVES 1. State the purpose of the Auxiliary Feedwater System. 2. List the major components in the AFW System and state the function of each. 3. Describe the operation of the AFW System during: a. Startup b. Hot standby c. Plant cooldown d. Emergency 4. Describe the normal line-up for the AFW System. 5. List the signals which initiate the automatic starting of the motor-driven and turbine-driven AFW pumps.

  4. Auxiliary Feedwater System Purpose: Serves as a backup system for feeding steam generators whenever RCS temperature is above 350F and main feed system is not available. Level must be maintained in SG even during emergency since SG is the reactor's heat sink.

  5. Components: • Two Motor Driven Pumps • One Steam Turbine Driven Pump • Two Condensate Storage Tanks • Associated Piping, Valves, & Controls

  6. From S/G #1 From S/G #2 To S/G #4 CST #1 To S/G #1 Pump 001 To S/G #2 To S/G #3 CST #2 Pump 002 Pump 003 Auxiliary Feedwater System Turbine Driven AFW Pump Motor Driven AFW Pump Motor Driven AFW Pump

  7. MDAFW Pump • Each pump is capable of 100% capacity. • 630 gpm (including recirculation flow) @1517 psi • Takes suction from one CST • Motors are air cooled • Each pump feeds 2 SGs

  8. MDAFW Pump • The pumps may be operated manually or will start automatically upon detected loss of heat sink and loss of power events • Automatically started by 1) Low water level in any one SG (2 of 3 coincidence) 2) Both MFPs tripped 3) SI (Safety Injection) 4) Blackout signal

  9. Motor Driven AFW Pump

  10. Motor Driven AFW Pump Suction Piping

  11. TDAFW Pump • Power supply is Main Steam pressure upstream of MSIV’s (Loops 1 & 2) • Exhaust to atmosphere • Apply feedwater to SGs during emergencies when the main feedwater and motor-driven pumps are inoperable • Capacity - 1175 gpm (almost twice capacity of MDAFW pump) • Aligned to all four SGs • Auto started by 2 SGs at low level setpoint (2 of 3 coinc per SG)

  12. Turbine Driven AFW Pump

  13. Condensate Storage Tanks(CST) • Vertical, cylindrical tanks of reinforced concrete with a stainless steel liner • CST #1 normally lined up to provide water to the AFW system (Manual valves) • CST #2 provides an alternate water source

  14. CST Capacity • Capacity - 480,000 gallons each • All non-safety system consuming CST water take a suction via a standpipe with nozzle level that ensures the minimum water level is maintained available

  15. CST #1 CST #2 Vacuum Degasifier System Overflow Basin

  16. AFW Actuation Signal • Automatic features - AFW is aligned to be placed in service automatically in the event of an emergency • Auxiliary feedwater actuation signal (Motor Driven) • SI signal (associated train) • Loss of offsite power (blackout) associated train • Lo-Lo Level in SG - 38% - 2/4 on 1/4 SG • Both SGFPs trip (2/2)

  17. TDAFW Actuation Signal • Actuating signals • Lo-Lo SG water level - 38% - 2/4 on 2/4 steam generators • Loss of offsite power (black out on either train)

  18. Objectives Review 1. State the purpose of the Auxiliary Feedwater System. 2. List the major components in the AFW System and state the function of each. 3. Describe the operation of the AFW System during: a. Startup b. Hot standby c. Plant cooldown d. Emergency 4. Describe the normal line-up for the AFW System. 5. List the signals which initiate the automatic starting of the motor-driven and turbine-driven AFW pumps.

More Related