An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 1.  LOW COST       2.  SIMPLE 3.  EFFICIENT

  2. EER • Energy Efficiency Ratio = Cooling Capacity in Btu / Hr Power Consumption in Watts

  3. Mechanical Subcooling • Moving cooling load from the main compressor to the subcooling compressor increases efficiency.

  4. R410A - A New Opportunity • R410A = compressor EERs of 14 to16 • Not a refrigerant for medium or low temperature refrigeration. • Line sizes must stay small due to high pressures, which points toward a one on one design.

  5. R410A Subcooling Medium Temp • R410A EER = 16.0 • Transferred BTUs • 200% Efficiency Gain Small Comp Big Compressor • R404A EER = 7.1

  6. R410A Subcooling Low Temp • R410A EER = 16.0 • Transferred BTUs • 400% Efficiency Gain Small Comp Big Compressor • R404A EER = 3.7

  7. R410A R404A

  8. The ETL Tests Medium Temp ETL is the established authority on refrigeration performance testing.

  9. The ETL Tests Low Temp ETL is the established authority on refrigeration performance testing.

  10. The ETL Report Download From BMIL.COM

  11. Smaller Refrigerant Charge Distributed Systems

  12. Smaller Refrigerant Charge Distributed Systems

  13. Frio Verde and R22 to R404A conversions.     1.  Some stores are converting R22 to R404A.     2.  Standard R404A has 66% more mass flow than R22 for the same heat transfer.     3.  The mass flow increase calls for suction line re-piping with standard R404A systems.     4.  Frio Verde R404A has the same mass flow as R22 due to subcooling at 50 ºF to 60 Deg ºF.     5.  Frio Verde saves $30k to $40k of re-piping cost on a 50,000 sq ft. supermarket conversion.