1 / 29

Amino Acid Analyser

2000.6.17 석사3기 박주영. Amino Acid Analyser. Amino Acid Analyser Products Ion exchange chromatography Application An example of application. Amino Acid Analyser. AMINO ACID ANALYSER (AAA)

winola
Download Presentation

Amino Acid Analyser

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. 2000.6.17 석사3기 박주영 Amino Acid Analyser Amino Acid Analyser Products Ion exchange chromatography Application An example of application

  2. Amino Acid Analyser • AMINO ACID ANALYSER (AAA) • Amino Acid Analyser is a specifically configured system optimised for the analysis of free amino acids. • PRINCIPLE • The system utilises ion-exchange chromatography incorporating post column reaction with ninhydrin and subsequent detection in the visible region spectrum.

  3. Amino Acid Analyser • Biochrom

  4. AAA: AccQ Tag • The AccQTag Method is based on a derivatizing reagent developed specifically for amino acid analysis. Waters AccQFluor Reagent (6-aminoquinolyl-N-hydrozysuccinimidyl carbamate, or ACQ) is an N-hydroxysuccinimide-activated hetrocyclic carbamate, a new class of amine-derivatizing compounds. Waters

  5. Chromatography • Open Column Chromatography • Thin Layer Chromatography • Liquid Chromatography • Ion exchange chromatography • Amino acid analyer • High Performance Liquid Chromatography

  6. Protein analysis Determination of Amino Acid Composition of Proteins 1) break down the polypeptide chain into its constituent amino acids , • hydrolysis (boiling in 6 N HCl) 2) separate the resulting free amino acids according to type, 3) measure the quantities of each amino acid. • chromatography

  7. Protein analysis Methods of protein purification • Differential centrifugation • Diferential precipitaion by soulbility difference • Column procedures • Preparative gel-exclusion chromatography • Column chromatography with protein binding • Ion-exchange chromatography • Affinity chromatography • High-performance Liquid Chromatography • Electrophoretic methods

  8. Protein analysis Determination of Amino Acid Sequence of Proteins • Sequenators (Edman degradation) phenylisothiocyanate + tetrapeptide - phenylthiocarbamoyltetrapeptide mild hydrolysis phenylthiohydantion derivative of NH2-terminal amino acid + original peptide minus NH2-terminal residue

  9. Ion exchange chromatography - 아미노산의 전기적성질 • 중성용액(pH7)에서 카르복시기는 -COO-로, 아미노기는 -NH3+ 로 존재한다. • 따라서 아미노산은 한 분자내에 양이온과 음이온을 동시에 가지지만 전체적으로는 중성인 성질을 띠게 된다.

  10. 이온교환크로마토그래피 • 아미노산이나 다른 용질의 분리에는 종종 이온교환 크로마토그래피를 이용하는데, 이때 대상분자는 전하를 띤 고체지지체의 다른 이온과 교환되었다가 다시 떨어져나온다. • 전형적인 과정에서는 액체상에 녹아있는 용질을 다공성 고체상이 채워진 관을 통과시킨다. • 액체상으로는 물이 보통 쓰이며, 고체상은 하전된 작용기를 가진 합성수지 입자로 된 층이다.

  11. Ion chromatograph -Principles of separation • Fig. illustrates the principle of retention by exchange of anions in anion-exchange chromatography,

  12. Ion exchange chromatography의 구성 • Instrumentation • pump • injector • detector • data station • Chemistry components • stationary phase • mobile phase

  13. Instrumentation of IC • Ion Chromatograph(IC), Dionex

  14. Instrumentation of IC AS40 Automated Sampler GS50 Pumps AutoSelect AS50 Autosampler EO1 Eluent Organizer EG40 Eluent Generator

  15. Instrumentation of IC • ED50 Electrochemical Detector • CD25 Conductivity Detector • PDA-100 Photodiode Array Detector • AD25 Absorbance Detector

  16. Ion chromatograph - System 구성

  17. Stationary phases of IC • 양전하를 가진 수지를 음이온교환체(anion exchanger), 음전하를 가진 고체 지지체는 양이온교환제(cation exchanger)라 한다 • Ion-exchangers are charaterized both by the nature of the matrix used as a support and the nature of the ionic functional groups on the surface.

  18. Stationary phases of IC Functional groups Cation Exchanger Anion exchanger Sulfonic acid -SO3- H+ Quaternary amine -N(CH3)3+ OH- Carboxylic acid -COO- H+ Quaternary amine - N(CH3)2(EtOH)+OH- Phosphonic acid PO3- H+ Tertiary amine -NH(CH3)2+ OH- Phosphinic acid HPO2- H+ Secondary amine -NH2(CH3)2+ OH- Phenolic -O- H+ Primary amine -NH3+ OH- Arsonic -HAsO3- H+ Selenonic -SeO3- H+

  19. Stationary phases of IC Functional groups • Strong anion-exchanger(SAX) • quaternary amine functional groups • Strong cation exchanger(SCX) • Sulfonic acid

  20. Stationary phases of IC Matrixes 1. Silica-based • better chromatographic efficiency, stability and durability in high pressure • limited pH range : 2< pH <7 2. Polymer-based • chemically derivatization of synthetic organic polymers • most widely used types of ion-exchaners • subject to pressure limitations • tolerance towards eluents and samples with extreme pH, between 0-14.

  21. Stationary phase for AAA • 양이온 교환매질 • 강산성, 폴리스티렌 수지(도웩스-50) • 약산성, 카르복시메틸렐룰로오스(CMC) • 약산성, 킬레이트화, 폴리스티렌수지(켈렉스-100) • 음이온 교환매질 • 강염기성, 폴리스티렌 수지(도웩스-1) • 약염기성, 디에틸아미노에틸(DEAE) 셀룰로오스

  22. Mobile phases of IC Properties of Mobile phases • compatibility with the detection mode • nature of the competing ion • concentration of the competing ion • mobiles phase’s pH • buffering capacity of the monile phase • ability to complex the ionic sample components • organic modifiers

  23. Mobile phases of IC Eluents for Anions • Aromatic carboxylic acids and their salts • mostly widely employed eluent • low conductances • ex) lithium hydroxide • Aliphatic carboxylic acid • Aromatic and aliphatic sulfonic acids • Potassium hydroxide • Polyol-borate complexes • Ethylenediaminetetraacetic acid -EDTA • Inorganic salts such as Cl-, SO42- or PO43-

  24. Mobile phases of IC Eluents for Cations • Inorganic acids such as nitric acid • Organic bases

  25. Ion chromatograph -Detection • Conductivity detection • Difference in the ionic conductance • Electrochemical detection • Electric oxidation-reduction potential • Spectroscopic detection • UV-VIS Absorption • Fluoescence • Refractive Index(RI) • combication with various forms of atomic spectrometrysuch as ICP MS

  26. Detection using ninhydrin for AAA • 아미노산은 닌히드린과의 반응을 통해서 쉽게 확인되고 정량될 수 있다. • 닌히드린(혹는 트리케토히드린덴 수화물)은 매우 강한 산화제로서, 알파 아미노 작용기의 산화적 탈아민화를 일으킨다. • 이 반응의 생성물은 알데히드, 암모니아, 이산화탄소, 그리고 닌히드린의 환원된 유도체인 히드린단틴(hydrindantin)이다. • 이때 생성되는 암모니아는 히드린단틴과 또다른 닌히드린 분자와 반응하여 570nm에서 분광학적으로 정량할 수 있는 보라색 생성물 루헤만 보라(Rhhemann’s Purple)를 형성한다.

  27. Amino Acid Analyser (Beckman model) • Detector • Wavelength range: 190-700 nm • Max. Sensitivity : 0.001 Absorbance units full scale(AUFS) • Autosamper : up to 80 samples • Possible range of flow rates : 0.01-10 ml/min • Sample • nature: liquid • size: 1-2 ml

  28. Application of Amino Acid Analyser • Physiological sample (blood, urine, CSF...) • Duran M., Dorland L., De Bree P.K., and Berger R. Selective screening for amino acid disorders. European Journal of Pediatrics. 1994; 153(1): S33-S37. • Food • M. Ghojale and M.Sayhoon. Comparative assessment of irradiated proteins in potato tuber with untreated control by High Performance Liquid Chromatography (HPLC) and gel electrophoresis. Radiation Physics and Chemistry. 1995 October-December; 46: 4-6.

  29. Application of Amino Acid Analyser • Molecular study • Wu T, Wu Y, Yuan Y, He H. and Zhang G. Study on amino aicd compositon of HSP70 and the level of plasma free amino acids of workers with long-term exposure to harmful factors. J Tongji Med Univ 1998; 18(4): 204-7. • 기타 • J. Csapo and Zs. Csapo-Kiss. Use of amino acids and their racemisation for age determination in archaeometry. Trends in Analytical Chemistry 1998; 17(3): 140-148.