An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. DCS progress VHV (MB) Laser (BN, GR) … TPC Detector Chamber mounted in FC at SXL2 Pre-commissioning is coming closer Overview drawings and equipment inventory FSM View TPC Status U. Frankenfeld

  2. TPC Very High Voltage Control Detector system progress Marco Boccioli U. Frankenfeld

  3. System tasks • Power supply control • Ramp up, ramp down • Safety monitoring • Intervention in case of • voltage trip • cooling system failure • gas system failure • Power monitoring • Monitoring of currents in field cage U. Frankenfeld

  4. interlocks Rack CR4-Z08 TPC cage PLC System overview “DCS” RS 232 CAN Ether net 1m Power S. 100m ELMB 2m ELMB U. Frankenfeld

  5. RECOVER OFF GO_STANDBY INTERLOCK GO_OFF GO_CONFIGURED STANDBY RECOVER GO_STANDBY GO_INTERMEDIATE CONFIGURE LOCAL CONFIGURED CONFIGURING RAMPDOWN RAMPDOWN CONFIGURING RAMPUP GO_STANDBY CONFIGURE GO_CONFIGURED GO_ON INTERMEDIATE CONFIGURING RAMPUP GO_STANDBY GO_INTERMEDIATE CONFIGURE GO_CONFIGURED ON State Diagram U. Frankenfeld

  6. Ramping up Check voltage Check interlocks Check RS232 Check CAN Set voltage Check current Check V drop 10kV 200V 1s 10’ U. Frankenfeld

  7. Safety monitoring U. Frankenfeld

  8. interlocks PLC Power monitoring “DCS” RS 232 CAN Ether net Power S. rampdown TPC cage ELMB ELMB Voltage trip U. Frankenfeld

  9. interlocks PLC Power monitoring “DCS” RS 232 CAN Ether net Power S. local TPC cage ELMB ELMB Communication fault U. Frankenfeld

  10. Testing Panels U. Frankenfeld

  11. Testing Panels U. Frankenfeld

  12. The devices Schneider ElectricPremium P57 5634M Heinzinger PNC 150000 U. Frankenfeld

  13. Conclusion • PLC control routines implemented and being tested • Power Supplier communication tested • ELMB communication tested • System purchased U. Frankenfeld

  14. DCS progress VHV (MB) Laser (BN, GR) … TPC Detector Chamber mounted in FC at SXL2 Pre-commissioning is coming closer Overview drawings and equipment inventory FSM View TPC Status U. Frankenfeld

  15. TPC(1) 2 1 2 2 1 10 18 18 1 6 12 216 1 108 12 288 436 2..4 216 1 72 1 06/07/05 [FSM?] Database(s) PVSS II PVSS II PVSS II Control room (ACR) OPCclient DIMclient User interface Ethernet CR3 CR3 CR4-Z08 CR3 CR3 CR3 PVSS II PVSS II PVSS II PVSS II PVSS II PVSS II OPC client Modbus/TCP OPC client DIMclient Virtual Serial OPC client ISEG OPCserver Wiener OPCserver E E E ELMB OPCserver CR3 [FED] PCI-CAN DIMserver PCI-CAN C E C CR4-Z08 DIMclient PLC C ACC E ACC S CR4-Y08 CR4-Z08 ISEG Heinzinger ACC UX-C08/D16 Eth.-RS232 UX-A,B,C UX-C/D PS Calibr.pulser Wiener Ethernetswitch Gatingpulser E HV LV ELMB HV ELMB DDL Chambers Chambers Chambers,detector RCU HVrod HVrod Chambers DIMsrv U. Frankenfeld High Voltage Low Voltage Temp. Monitor FEE Very High Voltage VHV Curr. Monitor Pulser system

  16. TPC(2) 1 1 4 18? 40 06/07/05 Ethernet CR3 SG2 CR3 CR3 PVSS II PVSS II PVSS II PVSS II Modbus/TCP DIMclient DIP OPC cl. ELMBOPC DIM client E E RS232 CR3 E [Vision] DIMserver/filesystem PCI-CAN [GWG] GasPVSS Video In [TS/CV] SG2 ELMB CR3 PLC [Motion][Laser] DIMserver Heinzinger TS/CVSCADA virtual serial SG2 Video HV Analysis DIMsrv Gas LHut UX-C UX-C Eth.-RS232 PLC PLC LHut LHut Spectronlaser Mirrorcontrol CR5 Gas CoolingPlant (ch) CoolingPlant (TS) Mirror adj. Trig Board(STAR) Mirror adj. Videocameras Chambers,detector HVrod ThermalScreen(s) Detector U. Frankenfeld Laser calibration system. Chamber Cooling VHV rod Cooling Thermal Screen(s) Gas system Drift velocity mon.

  17. DCS progress VHV (MB) Laser (BN, GR) … TPC Detector Chamber mounted in FC at SXL2 Pre-commissioning is coming closer Overview drawings and equipment inventory FSM View TPC Status U. Frankenfeld

  18. Hierarchy overview TPC HV ROC FC FEE TEMP Screen LASER GasD CO2 RCool VHV SSW Cone ROC TSen ....... +436x HV Gating FED CalibP LV GasD LaserC MirrorC ECool IROC OROC MISC GPulser PS A0 A1 36x … GPulser PS Sectors Crate PS Calib Image Mirror Ch Ch Ch Ch Ch Ch Ch Ch Ch ChGr ....... ....... ....... ....... ....... ....... ....... ....... ....... ....... 36x (2x) 36x 10x 98x ??x 6x 6x 72x ??x 36x U. Frankenfeld

  19. HV State single channel CONFIGURE (key) OFF GO_OFF SAVE_CONFIG CONFIGURE (key) GO_INTERMETIATE GO_ON Additional: A;B;C DOWNLOADING SAVING STBY_CONFIGURED CONFIGURE (key) STOP GO_ON SAVE_CONFIG RAMPING_DOWN_LOW RAMPING_UP_LOW SAVING INTERMEDIATE DOWNLOADING RAMPING_DOWN RAMPING_UP STOP GO_INTERMEDIATE ON U. Frankenfeld

  20. HV State multiple channels CONFIGURE (key) OFF GO_OFF CONFIGURE (key) GO_INTERMETIATE GO_ON Additional: A;B;C;D;E DOWNLOADING STBY_CONFIGURED CONFIGURE (key) STOP GO_ON RAMPING_DOWN_LOW RAMPING_UP_LOW INTERMEDIATE DOWNLOADING RAMPING_DOWN RAMPING_UP STOP GO_INTERMEDIATE ON U. Frankenfeld

  21. HV State channel(s) and crate GO_STANDBY GO_OFF CONFIGURE (keys) OFF GO_STANDBY CONFIGURE (key) GO_INTERMETIATE GO_ON Additional: A;B;C;D;E STANDBY DOWNLOADING STBY_CONFIGURED CONFIGURE (key) STOP GO_ON RAMPING_DOWN_LOW RAMPING_UP_LOW INTERMEDIATE DOWNLOADING RAMPING_DOWN RAMPING_UP STOP GO_INTERMEDIATE ON U. Frankenfeld

  22. A B C D E From any state if the communication with the hardware is lost When several modules in ERROR, External Interlock or power crate failure. It is the propagation of the interlock condition to the PS From any state when not all the channels in the same stable state From any state when not all the channels in the same stable state INTERLOCK RECOVER RECOVER_INTERLOCK NO_CONTROL ERROR INTERLOCK_WENT MIXED MIXED_LOW When the Communication is established When all channels are in the same stable state When all channels are in the same stable state Go to the appropriate state Go to OFF Go to OFF Go to the appropriate state Go to the appropriate state U. Frankenfeld

  23. HV State crate RECOVER Power Crate unsafe Conditions, Kill command ERROR Active lines for External Interlock and External disable INTERLOCK GO_ON RECOVER_INTERLOCK INTERLOCK_WENT OFF GO_OFF Network connection lost NO_CONTROL ON U. Frankenfeld