Wiring of Communication Modules mMINT, PMINT, MCAM and PCAM. mMINT Communication Wiring. Modbus RTU Network Master. RS-485 Modbus. SW3 should be moved to the ON position only when it is the last device in a chain of devices or if it is a single device. A. Tx/Rx +. Tx/Rx -. B. GND*.
E N D
mMINT Communication Wiring Modbus RTU Network Master RS-485 Modbus SW3 should be moved to the ON position only when it is the last device in a chain of devices or if it is a single device. A Tx/Rx + Tx/Rx - B GND* SHD *) Connect shield to ground at master device end only. Interconnect shielding where devices are daisy-chained. (For diagnostics) SW1 should be moved to the ON position only when it is the last device in a chain of devices or if it is a single device. IZM26 Integrated -Status (on/off) sensors -Shunt trip and spring release control only available with Digitrip models 1150x **) for diagnostic mode, to configure the mMINT Feed control voltage to A14 and A15 for breaker remote control and for Trip Unit operation without current flow. Terminal B1 Terminal B2 +, P 0V, N INCOM +, P Terminal A14 0V, N Terminal A15
PMINT Communication Wiring PROFIBUS DP Master RS-485 PROFIBUS DP Connect the INCOM Shield wire to ground at master device (PMINT) end only. SHIELD Position of breaker in drawer IZM-CS in position D IZM-CS in position C 6 5 4 3 2 1 IZM26 NO C NO C Integrated -Status (on/off) sensors -Shunt trip and spring release control only available with Digitrip models 1150x INCOM +, P 0V, N Feed control voltage to A14 and A15 for breaker remote control and for Trip Unit operation without current flow. GND CBSW2 Terminal B1 CBSW1 Terminal B2 +, P Terminal A14 0V, N Terminal A15
MCAM Communication Wiring* (Front View of MCAM) (Top View of a mounted MCAM on IZM) wiring for remote control (Shunt trip and spring release) Modbus Communications Adapter Module Cat. MCAM 5 Close 4 Open 3 COM - R 2 0V 24 Vdc- 1 24 Vdc+ 24 Vdc+ Modbus RTU Master Integrated Status (on/off) sensors in breaker Modbus Control 4 Shield GND** 3 Enable COM - C 2 Disable inverting A (Tx/Rx-) Tx/Rx- 1 B (Tx/Rx+) Tx/Rx+ Source Ground non-inverting RS-485 Modbus MCAM
PCAM Communication Wiring* (Front View of PCAM) (Top View of a mounted PCAM on IZM ) wiring for remote control (Shunt trip and spring release) Series NRX PROFIBUS Communications Adapter Module Cat. PCAM PROFIBUS DP Master RS-485 PROFIBUS DP PROFIBUS Control 5 Close 4 Enable Open Integrated Status (on/off) sensors in breaker 3 Disable COM - R 2 0V 24 Vdc- Source Ground 1 24 Vdc+ 24 Vdc+ PCAM
ECAM Communication Wiring* (Front View of ECAM) (Top View of a mounted ECAM on IZMX) wiring for remote control (Shunt trip and spring release) Series NRX Ethernet Communications Adapter Module Cat. ECAM 5 Close 4 Open 3 COM - R 2 0V 24 Vdc- 1 24 Vdc+ 24 Vdc+ Integrated Status (on/off) sensors in breaker Ethernet Control Enable Ethernet Network, Switch, or PC Connection Disable Source Ground ECAM
Modbus RTU Network RS-485 XV-102 USB-RS 485 Converter RS485 B A Pin 3 A Pin 7 B + - Pin 3 Pin 2 Modbus RTU B A TB2-1 B TB2-2 A XIOC-SER Tx/Rx- Tx/Rx+ XC200