Electronics Cooling

Electronics Cooling. Reference: Cengel, Heat Transfer, 2 nd Edition, Chapter 15. Introduction. All electronic components generate heat due to I 2 R (joule heating) Modern integrated circuits (ICs) approaching 10 10 components/chip heat fluxes up to 100 W/cm 2

Download Presentation

Electronics Cooling

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Electronics Cooling Reference: Cengel, Heat Transfer, 2nd Edition, Chapter 15 ME 259

  2. Introduction • All electronic components generate heat due to I2R (joule heating) • Modern integrated circuits (ICs) • approaching 1010 components/chip • heat fluxes up to 100 W/cm2 • Failure rate of electronic devices increases exponentially with operating temperature • Silicon p-n junctions • Absolute limit of 125C for “safe” operation • 85C desirable for extended life ME 259

  3. Supporting Electronic Equipment • Chip Carrier • heat flow paths • junction-to-case thermal resistance (Rjc) • Printed Circuit Board (PCB) • Single-sided • Double-sided • Multilayer • Enclosure • sealed • vented ME 259

  4. Common Cooling Methods • Conduction cooling • copper “heat frames“ attached to PCB • copper layers and “vias” within multilayer PCBs • Air Cooling with or w/o heat sinks • natural convection & radiation • forced convection with fans • Liquid cooling • direct immersion • indirect (hxer, pump) ME 259

  5. Electronics Cooling Models • Component Model • Semiconductor device • Heat sink, mini-fan, heat pipe, hxer • PCB • Enclosure Model • Chassis assembly • Environment • Air Flow Model • Chassis-mounted fans • Air intakes, exhausts, • Shrouds, ducted flow • System Model • Combines component, enclosure, and air flow models ME 259

  6. Component Model • Physical system • Thermal circuit • Typical values • Analysis ME 259

  7. Enclosure Model • Physical system • Thermal Circuit • Analysis ME 259

  8. Air Flow Model • Physical system: • Thermal Circuit • Analysis ME 259

  9. System Model • Thermal circuit • Analysis ME 259

  10. Example • Given: Enclosure containing 16 TO-3 style power transistors, mounted in sets of four, on four EG&G 435 series heat sinks. Transistor specsEnclosure specs Rjc = 7.0 C/W L = 60 cm Rcs = 0.09 C/W H, W = 20 cm qc = 10 W t = 3 mm Tj,max = 125 C k = 0.4 W/m-K ho = 10 W/m2-K To = 25 C o = 0.8 Heat Sink specs Find: Fan flow rate needed to keep Tj below 125C ME 259