An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Pulsar MX from 5kVA up to 20kVA 15 & 20 kVA 8 & 10 kVA MX 16U Frame 4 & 5 kVA 2 Pulsar MX + ModularEasy(European model) Pulsar MX RT 5 & 10 kVA MX 10U FrameComing Oct 2007!

  2. New range : upgrade without upfront cost, 2 major products : Pulsar MX : Best-in-class On-Line UPS  at 5 kVA Best-in-class features 2 hot-swappable Power and Battery sub-modules w/o load interruption Flexible connectivity Best supervision & management Pulsar MX 16U Frame : 15 & 20 kVA Modular Solution Similar features Based on 5kVA power & battery sub-modules Pulsar MX 10U Frame : 5 & 10 kVA Modular Solution – Coming 9/2007 Similar features Based on 5kVA power & battery sub-modules Parallels up to 10kVA for capacity or redundancy Designed to meet the requirements of key channels Distribution Jobs OEM / Key Accounts Pulsar MX at a glance

  3. Rack kit MX EXB 1xEXB 45 min 2xEXB 80 min 3xEXB 120 min Power sub-module Battery sub-module Pulsar MX RT, Pulsar MX Frame 5 kVA / 4.5 kW 15 kVA / 13.5 kWMX Frame 10 kVA + 5 kVA redundant5 kVA + 2 x 5 kVA redundant 20 kVA / 18 kW MX Frame 15 kVA + 5 kVA redundant10 kVA + 2 x 5 kVA redundant JUNE 06 JULY 07 Tower/Rack10 min Rack mounting kit included Rack mounting kit included Empty MX Frame for P&B s-m hosting / upgrades from 5kVA standalone units MX Transformer5000 Battery sub-module 5 kva Power sub-module

  4. Business continuity and high quality power : Input voltage range : 120 - 280 Volts (single phase input for MX & MX Frame) 250 - 465 Volts (three phase input for MX Frame) without batteries draining AC bypass /AC normal separate or common (MX Frame) PFC system: THDI < 7% Input frequency range : 40-70Hz High quality output : THDU < 3% Voltage fluctuation Frequency variation Input On-line mode Automatic bypass Perfect waveform Bypass-mode Output Filter Availability : Online double conversion • Benefits : • 0ms transfer time • Compatible with poor quality grid and genset • No battery draining

  5. Hot-swappability for : Power sub-module (24 lbs) Battery sub-module (64 lbs) Seamless maintenance Front access for sub-modules hot-swappable maintenance Automatic bypass mode when power module is pulled out • Bypass-mode • Normal Availability : Pulsar MX • Benefits : • Maintenance easiness • Without load interruption

  6. Pulsar MX ModularEasy Load Pulsar MX Availability : Parallel operation with MX ModularEasy • Start from a single Pulsar MX + ModularEasy • Combine a second Pulsar MX • Achieve parallel operation w/o load interruption : 1UPS + 1 redundant UPS Pulsar Mx price base= 100 ModularEasy = 35 Pulsar Mx price base= 100 • Benefits : • No oversized investment at first step • Parallel operation based on standard UPSs • Seamless operation for the secured device

  7. Pulsar MX Frame : modular system based on Pulsar MX 5000 Power and Battery sub-modules dynamic redundancy from N+1 to N+3: « Meta UPS » management front access hot swappability (power or battery sub-modules) automatic static switch bypass sized at 20kVA for increased availability Make-before-break manual general bypass lockable Availability : Pulsar MX Frame 15000 & 20000 • Benefits : • Optimum availability

  8. Ex : Redundancy mode Ex : Power extension mode Load: 18kVA 4 UPS + 0 UPS redundant Load: 12kVA 3 UPSs + 1 UPS redundant Pulsar MX Frame20000 Pulsar MX Frame20000 90% 90% 90% 90% 60% 60% 60% 60% 5 kVA Power s-m 5 kVA Power s-m 5 kVA Power s-m 5 kVA Power s-m 5 kVA Power s-m 5 kVA Power s-m 5 kVA Power s-m 5 kVA Power s-m Availability : Parallel operation with Pulsar MX Frame • Dynamic redundancy from N+1 to N+3

  9. 8 /5min 35 /20min 60 /40 min 95 /60min Availability : Pulsar MX 5000 • 10min standard at 70 % load = 3U • 3U EXB battery module = 2 x Battery sub-modules inside • Automatic battery detection • Up to 2 hours with 3 EXB modules 5 KVA @70%/100%

  10. Pulsar MX Frame 20 kVA 8min POWER BATT DC bus POWER BATT DC bus POWER BATT DC bus POWER BATT DC bus Pulsar MX FRAME Battery Extension • Example #1: 20kVA configuration Backup time 20 KVA @70%/100% 8 /5mn 35 /20mn 60 /40 mn 95 /60mn

  11. Pulsar MX Frame 15 kVA 8min Pulsar MX FRAME Battery Extension • Example #2: 15kVA configuration POWER BATT DC bus POWER BATT DC bus POWER BATT DC bus Backup time 15 KVA @70%/100% 8 /5mn 35 /20mn 60 /40 mn 95 /60mn

  12. Pulsar MX Frame: EXB integration recommendations • Rack • Do not forget to order • 6 foot Battery extension cables (68528) • 3 cables for any 15kVA installation • 4 cables for any 20kVA installation • Rail kit already included • Tower • For Pulsar MX 15kVA • Caster Kit (casters + floor mount stand + seismic bracket) (87410) • 1x MX / EX RT Battery integration System (86005) • 3x 6 foot battery.cable (68528) • For Pulsar MX Frame 20 kVA + 12 EXB please order: • Caster Kit (casters + floor mount stand + seismic bracket) (87410) • 1x MX / EX RT Battery integration System (86005) • 1x additional MX / EX RT Battery Integration System (86005) for 12 EXBs • 4x 6 foot battery.cable (68528)

  13. Pulsar MX Frame: EXB integration recommendations • Tower Configurations – 15kVA Installation 3 Extensions 9x EXBs 3x 6 foot cables 2x Batt.Integ.Kit 2 Extension 6x EXBs 3x 6 foot cables 1x Batt.Integ.Kit 1x Caster Kit 1 Extension 3x EXBs 3x 6 foot cables 1x Batt.Integ.Kit

  14. 1 Extension 4x EXBs 4x 6 foot cables 1x Batt.Integ.Kit 2 Extensions 8x EXBs 4x 6 foot cables 1x Batt.Integ.Kit 1x Caster Kit 3 Extensions 12x EXBs 4x 6 foot cables 2x Batt.Integ.Kit 1x Caster Kit Pulsar MX Frame: EXB integration recommendations • Tower Configurations – 20kVA Installation

  15. Flexibility: Pulsar MX Frame 2 models : 15 & 20 kVA • 1 versatile model for stand-alone & rack enclosures (31.5”+ depth) • Pulsar MX Frame 15 / 20000 = 16U for rack (D = 29.1”), 31.3” high for tower (with optional caster kit) • Delivered with: 8 min runtime + rail kit • Optional Caster kit and Network Management Card MX Frame stand alone Pulsar MX Frame rack integration • Benefits : • Integration in high density rack cabinets • Integration in technical rooms

  16. Local soft supervision and point to point shutdown Remote supervision via NMS or EPM, MGE superviser HP OpenView IBM Netview CA Unicenter HP Insight Manager DB9 Serial port/USB Personal Solution-Pac NMC Card Local electrical supervision and shutdown NMC modBus/ jbus (12/06) Web supervision MC Contacts/serial card UPS control DB9 5 voltage free output contacts 2 A 48 V DC Building Management System Comprehensive and multi-protocol supervision

  17. MX Frame 20 kVA 18 kW Pulsar MX 5 kVA 4.5 kW MX 10U Frame 10kVA9 kW MX Frame 15 kVA 13.5 kW 100 235 315 370 TCO : Power extension without upfront cost • Seamless migration from 5 up to 20 kVA at optimized cost

  18. MX 20kVA (16U) FRAME POWER Sub-module POWER Sub-module POWER Sub-module POWER Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module MX5000RT (3U) Chassis POWER Sub-module POWER Sub-module POWER Sub-module POWER Sub-module POWER Sub-module POWER Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module MX 20kVA MX5000RT (16U) FRAME (3U) Chassis Pulsar MX Migration5kVA Standalone to 20kVA Frame MX5000RT (3U) Chassis POWER Sub-module BATTERY Sub-module

  19. MX5000RT MX5000RT (3U) Chassis (3U) Chassis POWER Sub-module POWER Sub-module POWER Sub-module POWER Sub-module POWER Sub-module POWER Sub-module POWER Sub-module POWER Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module BATTERY Sub-module Pulsar MX SystemsComplete Systems/Kits Available Pulsar MX Pulsar MX (16U) FRAME (16U) FRAME POWER Sub-module BATTERY Sub-module Pulsar MX 5000 Transformer Pulsar MX RT 5kVA HV Part# 87050 Includes: (1) Pulsar MX RT (3U) Chassis with Rail Kit (1) Power Sub-module (1) Battery Sub-moduleFully assembled in one box Pulsar MX RT 5kVA LV Part# 87150 Includes: (1) Pulsar MX RT (3U) Chassis with Rail Kit (1) Power Sub-module (1) Battery Sub-moduleFully assembled in one box (1) MX 5000 Transformer (2U) Pulsar MX 15kVA HV Part# 87415 Includes: (1) Pulsar MX (16U) Chassis with Rail Kit (3) Power Sub-modules (3) Battery Sub-modules Each component in a separate box Pulsar MX 20kVA HV Part# 87420 Includes: (1) Pulsar MX (16U) Chassis with Rail Kit (4) Power Sub-modules (4) Battery Sub-modules Each component in a separate box (3U) Chassis

  20. Pulsar MX Frame vs competition

  21. Pulsar MX Frame vs APC Comments Pulsar MX Frame Symmetra LX MX Frame vs LX 15-20 kVA 12-16 kVA (4 kVA //) Tower / Rack 16U 19U Both models 800 mmHxWxD 653x444.5x735 mm 838x472x688 mm depth compatible I/O connection 8 IEC10A+4 IEC16A+in/output HW 8 IEC10A+10 IEC16A+in/ouput HW 8 IEC cords supplied + IEC lock system No Redundancy 15 kVA or 10+5 KVA redundant 12 kVA or 8+4 kVA redundant20 kVA or 15+5kVA redundant 16 kVA or 12+4 kVA redundant Loadshedding No F input range 40-70 Hz 45-65 Hz VA / Watt ratio 0.9 0.7 More Watt for MGE Efficiency (normal / ECO mode) 92% / 97% 90% / No ECO mode Interface LCD + LEDs + Mimic LCD + LEDs Multilingual LCD for both Combo 1/1 & 3/1 Automatic recognition Maintenance Front battery & power sub-modules Front battery & power sub-modules Battery test Monthly by default, daily, weekly Weekly by default, 14 days 1 UPS redundant 1 battery & 1 power module 1 battery & 1 power module U input range at 70% load 115-275 V 155-276 V Runtime 8 min  90 min 7.5 min  4 h 35 Options UPS control MBP, Transfo, PDU

  22. Pulsar MX Frame vs Chloride Comments Pulsar MX Frame Linear Plus MX Frame vs Linear Plus 15-20 kVA 12-18 kVA (6 kVA //) Format Tower / Rack 16U Tower HxWxD 653x444.5x735 mm 800x(3x300)x675 mm Interface LCD + LEDs + Mimic LCD + LEDs LCD only in English for Chloride I/O connection 8 IEC10A+4 IEC16A+in/output HW in/output HW 8 IEC cords supplied + IEC lock system No Maintenance Front battery & power sub-modules No Chloride: MBP in standard Redundancy 15 kVA or 10+5 KVA redundant 18 kVA or 12+6 kVA redundant20 kVA or 15+5kVA redundant - Combo 1/1 & 3/1 No Combo for Linear+ 10 kVA Automatic recognition No Optimal use of EXB cabinets in any situation Loadshedding No Options UPS control No U input range at 70% load 115-275 V 176-276 V F input range 40-70 Hz 47.5-52.5 Hz VA / Watt ratio 0.9 0.7 More Watt for MGE Operation & installation cost THDI<7% THDI<5%(1/1) ; THDI<25% (3/1) Efficiency (normal / ECO mode) 92% / 97% 91% / No ECO mode Communication 2 slots + free contacts 1 slot + free contacts USB & RS232 compatible RS232 compatible 1 UPS redundant 1 battery & 1 power module 1 battery & 1 power module Runtime 8 min  90 min 10 min  1 h 00 Battery test Monthly by default, daily, weekly From 7 to 180 days Accurate adjustment but not daily

  23. Pulsar MX Frame vs Socomec Comments Pulsar MX Frame Modulys MX Frame vs Modulys 15-20 kVA 18-24 kVA (6 kVA //) HxWxD 653 (16U) x444.5x735 mm 1824 (41U) x550x625 mm I/O connection 8 IEC10A + 4 IEC16A + in/output HW 1 IEC10A + in/output HW 8 IEC cords supplied + IEC lock system No Automatic recognition ? Optimal use of EXB cabinets in any situation Battery test Monthly by default, daily, weekly ? U input range at 70% load 115-275 V 161-276 V F input range 40-70 Hz 45-55 Hz VA / Watt ratio 0.9 0.7 Efficiency (normal / ECO mode) 92% / 97% 89% / 97% Communication 2 slots + free contacts 2 slots, free contacts USB & RS232 compatible RS232 compatible Tower / Rack Combo 1/1 & 3/1 Maintenance Front battery & power sub-modules Front battery & power modules Redundancy 15 kVA or 10+5 KVA redundant 18 kVA or 12+6 kVA redundant Socomec keeps the same 20 kVA or 15+5 kVA redundant 24 kVA or 18+6 kVA redundant UPS in a dedicated frame Interface LCD + LEDs + Mimic LCD + LEDs Multilingual LCD for both Runtime 8 min  90 min 8 min  35 min Loadshedding Options UPS control Transfo, UPS control Operation & installation cost THDI<7% THDI<6%(1/1)

  24. Pulsar MX Frame vs Liebert Comments Pulsar MX Frame Nfinity MX Frame vs Nfinity 15-20 kVA 12-16-20 kVA (4 kVA //) Format Tower / Rack 16U Tower HxWxD 653x444.5x735 mm 1372x508x711 mm I/O connection 8 IEC10A + 4 IEC16A + in/output HW in/output HW 8 IEC cords supplied + IEC lock system No Combo 1/1 & 3/1 No 16 kVA 1/1 or 3/1 ; 20 kVA only in 3/1 Automatic recognition No Optimal use of EXB cabinets in any situation Loadshedding No Battery test Monthly by default, daily, weekly 1, 2, 3, 4, 5 or 6 weeks VA / Watt ratio 0.9 0.7 Operation & installation cost THDI<7% THDI<4% (1/1), THDI<26% (3/1) PFC system for MGE Efficiency (normal / ECO mode) 92% / 97% 91% / No ECO mode Options UPS control Transfo Interface LCD + LEDs + Mimic LCD + LEDs + Mimic Multilingual for both Maintenance Front battery & power sub-modules Front battery & power sub-modules Redundancy 15 kVA or 10+5 KVA redundant 16 kVA or 12+4 kVA redundant 20 kVA or 15+5 kVA redundant 20 kVA or 16+4 kVA redundant U input range at 70% load 115-275 V 147-273 V F input range 40-70 Hz 40-70 Hz Runtime 8 min  90 min 7 min  1 h 45 min Communication 2 slots + free contacts 4 slots, free contacts USB & RS232 compatible RS232 compatible