Microscopie de photodétachement à 2 couleurs

Microscopie de photodétachement à 2 couleurs. C. Blondel, W. Chaibi, C. Delsart et C. Drag. Laboratoire Aimé Cotton, UPR 3321, CNRS, campus d’Orsay. Microscopie de photodétachement : principe. e. a. Principe : Y.N. Demkov et al., JETP Lett. 34 , 403 (1981)

Download Presentation

Microscopie de photodétachement à 2 couleurs

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Microscopie de photodétachement à 2 couleurs C. Blondel, W. Chaibi, C. Delsart et C. Drag Laboratoire Aimé Cotton, UPR 3321, CNRS, campus d’Orsay

  2. Microscopie de photodétachement : principe e a Principe : Y.N. Demkov et al., JETP Lett.34, 403 (1981) Microscopie de photodétachement : C. Blondel et al., Phys. Rev . Lett.77, 3755 (1996) Microscopie de photoïonisation : C. Nicole et al., Phys. Rev . Lett.88, 133001 (2002) Microscopie de photodétachement moléculaire : C. Delsart et al., Phys. Rev . Lett.89, 183002 (2002) z0

  3. y x détecteur : largeur à mi-hauteur 65 µm 1 électron toutes les 0,1 ms à 1 ms 7 8 6  1 : Doublet de lentilles simples ("einzellens") 2,5,9,10 : Plaques déflectrices 3,6,8 : Lentille simple 4 : Filtre de Wien  10 4 5 12 2 7 : Virage quadrupolaire  11 : Quadrupôle de focalisation  12 : Ralentisseur  13 : Zone d’interaction 9 1 11 13 3 énergie cinétique du jet : 300 à 500 eV  60 à 80 km.s-1 Jet d’ions et colonne de champ électrique hauteur de “chute” : z0 = 0,514 m F entre 150 et 450 V/m

  4. miroir de renvoi  l = 596885.3 pm F=258.6 V/m de 2 à 2000 s détecteur F photoélectrons jet d’ions Laser à colorant l = 535 à 710 nm (~ 596 nm) P = 100 à 400 mW Stabilité < 10 MHz sur 30 min (Sigmamètre) l mesurée ~ 2.10-8 (lambdamètre WSU) Rmax = 0,5 - 2,2 mm N = 1 – 9 e = 0,3 - 1,8 cm-1 i = 25 - 134 µm Acquisition (double passage)

  5. Si- j 3 / 2 e 4 2 m F = 0 3 q F h F = 427 Vm-1 ~ +/- 1% R • = 0,926 ± 0,002 cm-1 ± 0,008 cm-1 Analyse quantitative et spectrométrie électronique American Journal of Physics 66, 38 (1998) e3/2/F

  6. Affinité électronique A : e Espèce neutre hn A Ion négatif Molécules OHA(16O1H) = 14740,982(7) cm-1 J. Chem. Phys.122, 014308 (2005) SH A(32S1H) = 18669,543(12) cm-1 J. Mol. Spec., sous presse (2006) FluorA(19F) = 27432,451(20) cm-1 OxygèneA(16O) = 11784,676(7) cm-1 SiliciumA(28Si) = 11207,246(8) cm-1 SoufreA(32S) = 16752,9760(42) cm-1 Eur. Phys. J.D33, 335 (2005) Structure interne atomes et ions Soufre 32S: E(2P1/2)  E(2P3/2) = 483,5352(34) cm-1 32S: E(3P1)  E(3P2) = 396,0587(32) cm-1 J. Phys.B39, 1409 (2006) Détermination de l’affinité électronique hn est mesurée • 3/2/F est donné par l’ajustement (l’effet Doppler est pris en compte)

  7. 1ère couleur :e1 2ème couleur :e2 avec De=e1-e2 très bien connu e3/2/F De=3,898 GHz Microscopie de photodétachement à 2 couleurs

  8. P ~ 2*85 mW d ~ 1,2 cm Photodiode Synthétiseur n=1,949 GHz P =-2,3 dbm Amplificateur + 37 dB R1=80% piezo d ~ 3,85 cm l/2 Modulateur Electro-optique LiNbO3 R2=80% (l ~ 596 nm) P ~ 400 mW Système d’excitation à 2 couleurs

  9. 596894.89pm 5968886.21pm A(32S) = 16752.976 (40) cm-1 en laissant le champ électrique libre au lieu de 16752.9760(42) cm-1 Enregistrements et ajustements

  10. La « Microscopie de photodétachement » permet une utilisation quantitative des images pour de la spectroscopie de très haute résolution (2,5.10-7) La « Microscopie de photodétachement à 2 couleurs» conduit à déterminer l’énergie électronique indépendamment du champ électrique « Microscopie de photodétachement » en champ magnétique transverse et longitudinal T. Kramer et al. Europhys. Lett., 56 471 (2001) Bracher et al., Phys. Rev. A 73, 062114 (2006) « Microscopie de photodétachement » en régime pulsé (changement de détecteur + fabrication d’une chaîne laser pulsée monomode – 30 ns, 10 mJ) Conclusion et perspectives