White-Rodgers 70 Series ThermostatSelecting the Right Thermostat for the Job
White-Rodgers 70 Series Thermostats Agenda • Applications • Wiring • Configuration • Programming Featured Products In This Module • 1E/F78-151 • Single Stage / Programmable • Vertical and Horizontal • 1E72-151 • Heat Pump / Programmable • Vertical
Look at the Box for Detailed Information Staging By System Type Programming Options Applications Terminal Identification Part Number
White-Rodgers 70 Series Thermostat Overview The Digital Thermostats That Builds Your Business and Flexes Your Inventory • Vertical or Horizontal Options • Single Stage or Two Stage Heat Pump • Hardwire or Battery Only Options • Millivolt Compatible • Choice of Programmable or Non-Programmable • Meets California Building Code, Title 24 • Comfort Alert™ Compressor Protection • +/-1 Degree Accuracy- For Optimum Comfort and Equipment Life
White-Rodgers 70 SeriesSpecification Sheets Contain Detailed Information
White-Rodgers 70 Series Applications 1E Series (Vertical) 1F Series (Horizontal)
70 Series Application Jumpers and Switches • JUMPERS • W903, Disables EMR on Programmable Thermostats • W904, Changes Display From F° to C° • W905 , Slows the Cycle Rate by Opening the Temperature Differential for longer run times. This is typically used on hydronic applications • W906, For Emergency Heat 2nd Stage Fan Control • SWITCHES • O/B Reversing Valve. Determines when the reversing valve is energized • Electric/Gas, If used on an application where the fan is energized immediately on a call for heat (ie electric furnace or heat pumps) turn the switch to ELEC
Fossil Fuel Wiring 1E78 and 1F78 • For Two Transformer Systems Remove the Jumper Between RC and RH
Heat Pump Wiring • Reversing Valve Energized will be determined by either by “O” for Cooling or “B” for Heating Terminals • Jumper Required between “Y” and W to use on a Heat Pump • For Two Transformer Systems Remove the Jumper Between RC and RH 1E78 and 1F78 1F72 and 1F79 Reversing Valve Energized will be based on moving selection switch on back of subbase. Jumper Required between W2 and E to use a single Aux Heat for both 2nd Stage Heat and Emergency System Switch Operation
70 Series Navigation Day of Week Desired Temperature Time of Day Alternates to Actual Room Temperature Temperature or Config Adjustment Buttons 1E78 is the same but in a vertical position Fan Button Time Button Program Button Hold Button System Button Run Button
1F72-151 Entering System Configuration 2. Press Hold Button to Advance the Menu Most technical service calls are the result of improper system configuration 1. Press PRGM and RUN at the same time
Technical Service has never spoken to anyone who could not program the thermostat once they filled out the schedule worksheet in the manual and KEPT it. Save a call back and fill it out the form from the homeowners manual with the homeowner. Ensure they have the Homeowner Support Hotline: 800-284-2925 70 Series Programming Worksheet
70 Series Set Time and Day Set Current Time and Day Press TIME button once. The display will show the hour only Press and hold either UP or DOWN until you reach the correct hour and AM/PM designation (AM begins at midnight; PM begins at noon) Press TIME once again. The display window will show the minutes only. Press and hold either UP or DOWNuntil you reach the correct minutes. Press TIME once again. The display will show the day of the week. Press UP or DOWN until you reach the current day of the week. Press RUNonce. The display will show the correct time, day, room temperature and set-point temperature.
70 Series How To Set A Program Move the SYSTEM switch to Heat Press PRGM once. “Mo Tu We Th Fr” (indicating weekday program) will appear in the display. Press UP or DOWN to change the displayed temperature to your selected temperature for the 1st program period. Press TIME once (the programmed time will flash). Press UP or DOWN until your selected time appears. The time will change in 15 minute increments. When your selected time is displayed, press TIME again to return to the change temperature mode. Press PRGM once. The currently programmed start time and setpoint temperature for the 2nd program period will appear. Repeat steps 4 and 5 to select the start time and temperature for the 2nd program period. Repeat steps 4 through 6 for the 3rd and 4th program periods. Press PRGM once. “SA” (indicating Saturday program) will appear in the display, along with the start time for the 1st period and the currently programmed temperature. Repeat steps 4 through 8 to complete weekend programming. When you have completed entering your program, press RUN.