1.37k likes | 1.71k Views
2014 MTSC Training Course. MOXA Automation Session. Agenda. What’s HOT? New RTU Controller Products Introduction ioPAC 8500 Series ioPAC 5542 Series New Remote I/O Products Introduction 2013 New Products: ioLogik E1213 / E1261W-T / E2200-T C1D2/ATEX support: ioLogik E1200 series
E N D
2014 MTSC Training Course MOXA Automation Session
Agenda • What’s HOT? • New RTU Controller Products Introduction • ioPAC 8500 Series • ioPAC 5542 Series • New Remote I/O Products Introduction • 2013 New Products: ioLogik E1213 / E1261W-T / E2200-T • C1D2/ATEX support: ioLogik E1200 series • 2014 New Products: ioLogik W5340 HSPA / E1200H series • ioPAC 8500 / 5500 Series Implementation Introduction • RTUxpress + ISaGRAF Confidential
What’s HOT? New RTU Controller Products Introduction Confidential
4 Confidential
Precise Data Acquisition Dedicated ARM Based I/O CPU Speeds Up AI Sampling Rate • Available models • 85M-3801-T • 85M-3811-T 6 • 5 kHz per channel sampling rate can get more precise data than 10 Hz per channel • Benefits • More accurate to analyze analog events • E.g., motor current status of the point machine
Precise Data Acquisition Pre-Recording Analog Input Data Before Event Trigger • Available models • 85M-3801-T • 85M-3811-T • ioPAC 5542 AI Missing Data! 7 • Pre-recording functionprevents data loss between event trigger and recording start point • Benefits • More accurate to analyze analog events • E.g., data logging after point machine is triggered.
Precise Data Acquisition I/O CPU Labels DI & AI Millisecond-Level Timestamps 1st Slot DI module I/O CPU DI0_Ch0 01:30:28.001 1st 2nd Slot DI module I/O CPU DI1_Ch4 01:30:28.008 4th 3rd Slot AI module I/O CPU AI0_Ch2 01:30:28.003 2nd Main CPU 4th Slot AI module I/O CPU AI1_Ch5 01:30:28.006 3rd 8 • Users can easily compare event sequence at the millisecond level • Benefits • More accurate to analyze events based on millisecond sequence in time
Sustainable system reliability Rail-Level Surge and ESD Protection • ESD & Surge Requirement Comparison About 1.5 to 4 times higher than CE • EN 50155: Safety standard for electronic equipment used on rolling stock(Not apply on ioPAC5542) • EN 50121-3-2: EMC standard for electronic equipment used on rolling stock • EN 50121-4: EMC standard for electronic equipment used in trackside 9
Sustainable system reliability Rail TX Class Ambient Temperature Compliance ioPAC 8500 support -40 to 75°C ioPAC 8500 series not only compliant with EN 50155 Rail TX class ambient temperature standards, but also supports operating temperatures (outside vehicle) between -40 to 75°C (-40 to 167°F).
Sustainable system reliability Compliant with UL C1D2 and ATEX Zone 2 Certifications (ioPAC 5542) • UL Class I, Div. 2 • Where ignitable concentrations of flammable gases, vapors, or liquids are present within the atmosphere under abnormal operating conditions • ATEX Zone 2 • An area in which an explosive mixture is not likely to occur in normal operation and if it occurs it will exist only for a short time
Sustainable system reliability HSPA Cellular Function Support 15 times faster than HSDPA Mbps Transmission speed is much faster than HSDPA solutions
Easy installation and replacement Compact Design 2 Slots 114.7 x 135 x 100 mm 9 Slots 292.5 x 135 x 100 mm 5 Slots 190.9 x 135 x 100 mm 90.05 x 135 x 105.4 mm 90.05 x 135 x 105.4 mm • Benefits • Easy installation in a compact cabinet • Save space and costs
Easy installation and replacement Easy Module Replacement • Hot Swappable • Hot swap ioPAC 8500 modules without powering off devices, including I/O and communication modules • Benefits • Shorter system downtime • Easy installation and replacement for field engineers Confidential
RTUxpress Configure Ready-to-Run Services without Using APIs API List RTUxpress • Ready-to-Run Services • Simply configure Alarm, Data Logging, or Active OPC Server services through RTUxpress • No need to learn from APIs • Benefits • Get familiar with Moxa RTU easily • Lower down programming efforts • Focus on main application algorithm, numerical computing and control logic design
RTUxpress Simply Using RTUxpress to Configure Device • RTUxpress • An express tool for users to configure ioPAC 8500 and ioPAC 5500 devices • Benefits • Offline configuration for saving packet expenses • Included in product package without extra charge and upgradable in the future Confidential
RTUxpress Easily Link I/O and Services with TagEasy • TagEasy • Create I/O tags through RTUxpress. • Read/Write I/O status by accessing tag value • Link I/O tags and services through RTUxpress • Directly trigger services by I/O status change • Benefits: • Easy to access I/O values • Easy to trigger services Confidential
What’s HOT? New Remote I/O Products Introduction Confidential
What’s HOT New Products – 2013 Q3 & Q4 • ioLogik E1213 – Source type DO model • ioLogik E1261W-T – For wind power application • ioLogik E2200 series – All wide-temp models available now Product Improvements • ioLogik E1200 support C1D2/ATEX New Products – 2014 Q1 • ioLogik W5340-HSPA – HSPA micro RTU controller • ioLogik E1200H series – For offshore wind power applications Confidential
2013 New Products ioLogik E1213 – Source type DO model ioLogik E1261W-T – For wind power applications ioLogik E2200 series – All wide-temp models available now Confidential
ioLogik E1200 Series Target For general applications Features Active communication with patented Active OPC Server 2-port Ethernet switch for daisy-chain topologies User-defined Modbus/TCP addressing Features Features ioLogik E1200 series
- + ioLogik E1213 DOWiring & Option 12V DO0/2 - DO1/3 GND Field Power 9V Up to 36V Note1:Use Jumper to select either the DO channel to be 9V, 12V or Field power Note2:You are only allow to be select one of the power output , Field power(JP10)/12V(JP5)/9V(JP11) Note3 : EXT power has to connect to a 15 to 30 VDCpower source EXT Confidential
ioLogik E1261W-T Target For wind power applications Features I/O combination design for wind power applications Active communication with patented Active OPC Server User-defined Modbus/TCP addressing User-friendly configuration via web browser Features Features ioLogik E1261W-T Confidential
DIO RTD AI Door, smoke,..etc control & monitoring Motor temperature monitoring three-phase motor monitoring Wind Turbine Monitoring Application I/O combination design for wind turbine monitoring Applied in thousands of wind turbine applications in China
ioLogik E2200 Series Features Active communication with patented Active OPC Server Smart alarm management with e-mail, SNMP Trap, TCP, UDP Front-end intelligence with patented Click&Go control logic, up to 24 rules Supports SNMPv1/v2c/v3 protocol Features ioLogik E2200 series * Datasheet: http://www.moxa.com/support/download.aspx?type=support&id=1485
Product Improvements ioLogik E1200 support C1D2/ATEX Confidential
Class I, Division 2 / ATEX Zone 2 Certified for Harsh Environments • With UL Class I Division 2 and ATEX Zone 2 certifications, the ioLogik E1200 meets the demanding requirements of a variety of hazardous applications, and enhances the safety and reliability for remote monitoring in harsh environments. Confidential
Target Market for C1D2/ATEX Oil & Gas will be the target market for C1D2/ATEX certified products Confidential
2014 New Products ioLogik W5340-HSPA – HSPA micro RTU controller ioLogik E1200H series – For offshore wind power applications Confidential
ioLogik W5300 Series Features Easily manage devices over dynamic/private IP cellular network Active communication with patented Active OPC Server Front-end intelligence with patented Click&Go control logic, up to 24 rules 3-in-1 RS-232/422/485 serial port for connecting to serial field devices Up to 32 GB SDHC data logging function Features ioLogik W5300 series * Datasheet: http://www.moxa.com/support/download.aspx?type=support&id=1485
HSPA Cellular – Much Faster Than HSDPA • Transmission speed is much faster than HSDPA solutions 15 times faster than HSDPA Mbps
Cellular Function Improvement More selections for cellular setup to fulfill different ISP requirements Confidential
Cellular Reconnection Improvement Provide two options for auto reconnection • Modem Restart – When an error occurs during the Carrier check or PING check, W5300 will restart the cellular module automatically • System Reconnect – After the cellular module restarts for a period of time and the device is still unable to connect back to network, W5340 will reinitiate the system Confidential
ioLogik E1261H/E1263H-T Target • For offshore wind power applications Features • I/O combination design for wind power applications • Active communication with patented Active OPC Server • User-defined Modbus/TCP addressing • User-friendly configuration via web browser • IEC 60945 approval for harsh maritime environments • Specifications subject to change without notice. 34 Confidential
Designed for Offshore Wind Turbine Monitoring I/O combination design for wind turbine monitoring Comply IEC 60945 – for offshore wind turbine / marine applications Robust design – wide temperature, aluminum enclosure, DIN-rail, spring-type terminal block for harsh environments
ioPAC 8500 / 5500 Series Implementation Introduction RTUxpress + ISaGRAF Confidential
RTUxpress An express tool to configure ioPAC 8500 and ioPAC 5500 devices Offline configuration for saving packet expenses Easy to setup device Easy to manage tags Easy to configure ready-to-run services Included in product package without extra charge and upgradable in the future
Configure Ready-to-Run Services without Using Function Blocks No need Function Blocks RTUxpress • Ready-to-Run Services • Simply configure Alarm, Data Logging, or Active OPC Server services through RTUxpress • No need to learn from FBs • Benefits • Get familiar with Moxa RTU easily • Lower down programming efforts • Focus on main application algorithm, numerical computing and control logic design
RTUxpress Simply Using RTUxpress to Configure Device • RTUxpress • An express tool for user to configure ioPAC 8500 and ioPAC 5500 devices. • Benefits • Offline configuration for saving packet expenses • Included in product package without extra charge and upgradable in the future Confidential
RTUxpress—ioPAC RTU Utility Title & Menu Bar Shortcuts Device Configuration Moxa ready-to-run service Tag dictionary
RTUxpress Title & Menu Bar Confidential
Title & Menu Bar For on-line command, password key-in is must. (default: root) Confidential
RTUxpress Device Configuration Confidential
Device Configuration • By slot no. • Serial Port Setting • LAN Port Setting • HSPA Setting • I/O Setting • Time Setting • FTP Account Setting • Internal Register • System Register Confidential
Device Configuration—Serial Port Confidential
Device Configuration—Serial Port Confidential
Device Configuration—LAN port LAN information LAN setting Global setting Confidential
Device Configuration—HSPA HSPA configuration (Setting) Tag information Confidential
Device Configuration—HSPA HSPA configuration (Reconnection) Confidential
Device Configuration—DI Channel information Channel configuration Tag information Confidential