270 likes | 544 Views
THE OXYACETYLENE TORCH. AENT2803 ASSIGNMENT #10 DR.CURTIS BORNE. #1 PART I CUTTING TORCH RIG. LABELLING O/A EQUIPMENT 1. WORKING PRESSURE GAUGE 2. CYLINDER PRESSURE GAUGE 3. OXYGEN REGULATOR. 1. 2. 1. 2. 3. O x y g e n. gas. LABELLING PARTS CONTINUED. 4. ACETYLENE REGULATOR
E N D
THE OXYACETYLENE TORCH AENT2803 ASSIGNMENT #10 DR.CURTIS BORNE FORT VALLEY STATE UNIVERSITY
#1 PART I CUTTING TORCH RIG • LABELLING O/A EQUIPMENT • 1. WORKING PRESSURE GAUGE • 2. CYLINDER PRESSURE GAUGE • 3. OXYGEN REGULATOR 1 2 1 2 3 O x y g e n gas FORT VALLEY STATE UNIVERSITY
LABELLING PARTS CONTINUED • 4. ACETYLENE REGULATOR • 5. HOSES • 6. TIP • 7. TORCH • 8. SPARKLIGHTER • 9. WRENCH 3 O x y g e n gas 5 FORT VALLEY STATE UNIVERSITY
2. PRESSURE READINGS • HIGH PRESSURE IN CYLINDER • CYLINGER PRESSURE • LOW PRESSURE IN TORCH • WORKING PRESSURE FORT VALLEY STATE UNIVERSITY
TORCH HOSES • 3. OXYGEN HOSE IS GREEN • 4. ACETYLENE HOSE IS RED FORT VALLEY STATE UNIVERSITY
5. CUTTING PRESSURE SETTING • RATIO OF 2.5 PSI OF OXYGEN • TO 1 PSI OF ACETYLENE • NEVER OVER 15 PSI OF ACETYLENE • THICKNESS OF METAL AND TIP SIZE DETERMINES PRESSURE
OXYACETYLENE WELDING • USES LOWER PRESSURE • 3 PSI ACETYLENE • 7.5 PSI OXYGEN
6. OPEN OXYGEN CYLINDER • OPEN ALLTHE WAY
7. OPEN ACETYLENE CYLINDER • NOT MORE THAN1-1/2 TURNS
8. GAUGES • ON REGULATORS
9. MANIFOLD TORCH SYSTEM • AT FVSU CYLINDERS OUTSIDE • GASES PIPED INTO MULTIPLE STATIONS
10. OXYGEN CYLINDERS • RIGHT HAND CONNECTOR THREAD
11. OXYACETYLENE GOGGLE • #6 FILTER LENS USED FOR TORCH WORK • DON’T BE STUBBURN REMEMBER TO WEAR GOGGLES
12. CHECKING FOR TORCH LEAKS • USE SOAP AND WATER
13. HOSE CONNECTIONS • SHOULD BE HAND TIGHT
14. PARTS OF CUTTING TORCH 6 5 3 2 • 1. CUTTING TIP • 2. MIXING CHAMBER • 3. TORCH HEAD • 4. OXYGEN SET AT TWO PLACES • 5. ACETYLENE AT ONE PLACE • 6. OXYGEN LEVER 1 4
SETTING CUTTING FLAME • WEAR GLOVES & #6 LENS GOGGLES • HOLD TORCH IN BOTH HANDS • USE NEUTRAL FLAME • TOO MUCH ACETYLENE SENDS FLAME AWAY FROM TIP • TOO LITTLE CAUSES BLACK SMOKE
OBTAINING NEUTRAL FLAME • 1. OPEN ACETYLENE 1/2 TURN • 2. USE STRIKER TO LIGHT • 3. OPEN OXYGEN SLOWLY UNTIL FLAME IS NEUTRAL Flame Tip
CUTTING PROCEDURE • PREHEAT UNTIL CHERRY RED • PRESS OXYGEN LEVER • MOVE STEADLY ACROSS METAL • IF YOU MOVE TOO FAST CUTTING STOPS AND MUST PREHEAT AGAIN
TORCH SAFETY • #6 FILTER LENS • FASTEN CYLINDERS WITH CHAIN • KEEP SAFETY CAPS ON CYLINDERS • CHECK FOR LEAKS WITH SOAPY WATER • NEVER PUT OIL ON EQUIPMENT
SAFETY CONTINUED • OPEN ACETYLENE CYLINDER 1-1/2 TURNS • POINT TIP AWAY FROM YOU AND OTHERS • USE PROPER PRESSURE (LESS THAN 15 PSI) • USE STRIKER NOT MATCHES • NEVER LAY LIGTHED TORCH DOWN
SHUTTING DOWN PROCEDURE • TURN OFF ACETYLENE FIRST AT TORCH • TURN OFF OXYEN AT TORCH • CLOSE CYLINDERS • DRAIN HOSES