1 / 4

The SEN-10245 50kg L oad Cell And The Wheatstone Bridge.

The SEN-10245 50kg L oad Cell And The Wheatstone Bridge. Basic setup and operation. Apply 12vDC to circuit. Connect three resistors and Strain gauge in a Wheatstone Bridge Configuration. Circuit Setup.

xuxa
Download Presentation

The SEN-10245 50kg L oad Cell And The Wheatstone Bridge.

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. The SEN-10245 50kg Load Cell And The Wheatstone Bridge. Basic setup and operation.

  2. Apply 12vDC to circuit. • Connect three resistors and Strain gauge in a Wheatstone Bridge Configuration. Circuit Setup

  3. With no strain on the load cell, adjust the potentiometer to balance the bridge. Once the voltage meter reads 0.00vDC, the bridge is said to be balanced. The voltage reading becomes more defined as you adjust the voltage range of the volt-meter to smaller scales. Keep zeroing the bridge until you reach the smallest range. In this example that would be 200mvDC. The bridge is very sensitive while balancing the last few µvDC. Using a ten turn trim pot (not pictured) will make the balancing process easier. Balancing the Bridge.

  4. Apply pressure to the sensor. Remove pressure. Documenting the effect of strain across the Wheatstone Bridge.

More Related