1 / 21

Halftoning and Objective Quality Measures for Halftoned Images

Halftoning and Objective Quality Measures for Halftoned Images. Halftoning With Pre-Computed Maps Objective Image Quality Measures. Halftoning With Pre-Computed Maps. FM halftoning using threshold matrices High computational speed Trade-off between quality of tints and quality of shades

yachi
Download Presentation

Halftoning and Objective Quality Measures for Halftoned Images

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Halftoning and Objective Quality Measures for Halftoned Images • Halftoning With Pre-Computed Maps • Objective Image Quality Measures

  2. Halftoning With Pre-Computed Maps • FM halftoning using threshold matrices • High computational speed • Trade-off between quality of tints and quality of shades • Optimization criteria can not be fulfilled for every tone value • PreCoM • Meet both requirements for all tint levels • Without any loss in speed

  3. Pre-Computed Maps, PreCoM • Pre-computed maps, representing every tone value • Halftone volume • Image value as index • No comparison • No information from neighboring pixels

  4. Computing the maps • Individually optimized- Full control of the dot pattern for each tone value • Dots in each map maximally dispersed- Avoid graininess • Correlation between adjacent maps- No discontinuity effects

  5. Computing the maps • Arbitrary pattern • Gaussian low-pass filter • Locate tightest cluster (maximum) and largest void (minimum) • Remove dot at tightest cluster • Move to largest void • Continue until no further change occur

  6. Computing the maps Gaussian low-pass filter Change the width accordingto tone value Circular convolution

  7. Creating the locally correlated volume • Optimize • Start with 20% tone value • Add extra dots to create new tone value • Optimize, using the new filter • Continue the iterative process until all maps are created

  8. Results PreCoM Error diffusion

  9. Summary, PreCoM • Pre-computed maps • Individually optimized • Locally correlated • Tints without graininess • Smoothly varying shades • No loss in computational speed

  10. Objective Image Quality Measures • Image quality? • A reproduced image’s resemblance to a digital original • Purpose: evaluate halftone images • Printed • Observed by humans • Evaluate the perceived difference between the printed halftone and the original

  11. Requirements • evaluate all kinds of halftones • evaluate halftones for all kinds of printing techniques • judge the quality of real images, not only synthetic test patterns • return measures for several aspects of quality that are well correlated with results from subjective tests An objective quality measure should be able to:

  12. The Evaluation model • Use printed images? • Uncontrolled variations • Possible artifacts from scanning • Use models! • Print model • Mechanical dot gain • Optical dot gain • Observer model • Contrast Sensitivity Function

  13. Separation of information • Two different types of errors will be mixed: • parts of the original that the halftone could not reproduce • errors introduced by the halftone algorithm • Separate image information: • Halftone carrier • Reconstructed original

  14. Reconstructing the original • Extract as much as possible of the original without including the carrier • Use original as reference • Fourier spectrum • Low-pass filter? • No simple band limit! • Use an adaptive filter in the Fourier domain

  15. The Adaptive filter • Both magnitude and phase of the frequency components are changed by the halftoning process • The greater the phase difference, the less of the original is described • Take the vector in phase with the halftone that minimizes the Euclidean distance to the original • The remainder of the halftone component is the halftone carrier, describing the halftone characteristics

  16. Measuring quality • Reconstructed original • The difference to the original shows information lost in the halftoning process • The capability for the halftone to reproduce the original • Halftone carrier • Extra information introduced into the halftone • May cause disturbances

  17. Measuring quality • Radial histogram in the Fourier domain • The average energy in each frequency band

  18. Weight functions • Numbers on certain aspects of quality • Use weight functions to emphasize different frequency bands

  19. The Quality Measures • Quality measures derived from the error functions: • Low Frequency deviation, LFDev • Loss of Detail, Lod • Loss of Fine Detail, LoFD • Quality measures derived from the carrier functions: • Low Frequency Disturbance, LFD • Medium High Frequency Disturbance, MFD • Very High Frequency Disturbance, VHFD

  20. Summary • Method for objective quality measures for halftone images • Evaluates the perceived printed image, using models for the print and the observer • Evaluates both the halftone’s truthfulness to the original and the halftoned characteristics • 6 Different quality measures, emphasizing on different aspects of image quality • Meets the requirements stated initially

More Related