1 / 29

Some ECC features studied with GenIma

Some ECC features studied with GenIma. Efficiency with no fog Efficiencies with fog Micro-track number versus fog Distortions effects Sensitivity to grain density Compton or electrons background Neutrino events. Gen ima GEN : GEANT3 generation of

yael
Download Presentation

Some ECC features studied with GenIma

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Some ECC features studied with GenIma Efficiency with no fog Efficiencies with fog Micro-track number versus fog Distortions effects Sensitivity to grain density Compton or electrons background Neutrino events Jean Favier OPERA Meeting Ankara 3/04/09

  2. Genima GEN : GEANT3 generation of - single track (1 single field 200x200 2 , double layer emulsion set-up) - or neutrino, showers events in a complete brick set-up. - The correct grain density is set by randomly eliminating some GEANT track hits to obtain the m.i.p density at : 34 grains/100) IMA: single “classico” FORTRAN program: - read GEANT hits - add background fog - constructs the 32 images of grains, fog,etc present in the 2 emulsion layers - clusterises the images pixels - finds micro-track - finds base-track Jean Favier OPERA Meeting Ankara 3/04/09

  3. Fog generation Random generation; fog density from 0 to 30 grains/1000 3 • Clustering -Emulsion grain : 0.4  radius sphere -In input, pixels not saturated; then saturation to 256 above a threshold ( about 10 % of the saturated value); for layer 1 the threshold is 20 % lower to take account of light attenuation in emulsion ( att=300 micron)). Clusters of surface s  4 and s  64 pixels are eliminated No digital filter (coded but not used for timing reason…) Jean Favier OPERA Meeting Ankara 3/04/09

  4. Micro-tracks reconstruction - Initialisation: 2 hits tracks are made with each cluster found in plane 1 to 7 associated with any cluster found in plane 10 to 16. - Then try to fish other hits in the rest of planes by using roads ; road width depends of the track angle. Fog makes difficult a good evaluation of the residual sigmas - Select tracks with  6 points and qui2 < 4.5 REMARK: for the same physical track, you can obtain more than one (ex 10) sligthly different micro-tracks. All are kept for base-tracks reconstruction Jean Favier OPERA Meeting Ankara 3/04/09

  5. 0 mrad 100 mrad Residuals Fog=0 200 mrad 300 mrad 400 mrad 500 mrad 600 mrad Jean Favier OPERA Meeting Ankara 3/04/09

  6. 100 mrad 0 mrad Residuals fog=8 200 mrad 300 mrad 400 mrad 500 mrad 600 mrad Jean Favier OPERA Meeting Ankara 3/04/09

  7. b Widening of residuals when fog increases Jean Favier OPERA Meeting Ankara 3/04/09

  8. Jean Favier OPERA Meeting Ankara 3/04/09

  9. Not well adjusted parameters for sigmas variation with angle Jean Favier OPERA Meeting Ankara 3/04/09

  10. Base-tracks reconstruction -Comparison in the midle plane of the intercepts and the angles of the two tried micro-tracks. x, y  S1 slopex, slopey  S2 S1=C/ (1-tg ) S2=D/ (1-tg ) - C= 3 micron - D=16 mrad Jean Favier OPERA Meeting Ankara 3/04/09

  11. Base-track efficiency Fog=0 Jean Favier OPERA Meeting Ankara 3/04/09

  12. How fog can influence efficiency ? - Fog effects will be higher at large angle where the sensible volume around the track is higher • infection of a good cluster: the resulting barycentre becomes out of association: the hits number can go down from 6 to 5 - Deformations of good clusters by a fog one can produce a deterioration of qui2 • Oppositely, on a 5 hits track, one fog cluster can, by luck, occupy the sixth rank, so the track will be accepted Jean Favier OPERA Meeting Ankara 3/04/09

  13. Jean Favier OPERA Meeting Ankara 3/04/09

  14. Base-track efficiency Fog effect Jean Favier OPERA Meeting Ankara 3/04/09

  15. Jean Favier OPERA Meeting Ankara 3/04/09

  16. Base-track efficiencies when fog increases Jean Favier OPERA Meeting Ankara 3/04/09

  17. Distortion It is simulated by random rotation (0 to max) of the microtracks ,leaving fixed the intercept with the basis; we varied max from 0 to 40 mrad Emulsion layer 1 basis Jean Favier OPERA Meeting Ankara 3/04/09

  18. Jean Favier OPERA Meeting Ankara 3/04/09

  19. Micro-tracks number Jean Favier OPERA Meeting Ankara 3/04/09

  20. Random micro and base tracks with fog 500 mrad cut 700mrad cut Jean Favier OPERA Meeting Ankara 3/04/09

  21. Grain density fog=8 400 mrad 0 mrad Jean Favier OPERA Meeting Ankara 3/04/09

  22. Nhit 5 Grain density Fog=0 (preliminary) Nhit 6 Jean Favier OPERA Meeting Ankara 3/04/09

  23. Emulsion simulation Compton • 16 images Jean Favier OPERA Meeting Ankara 3/04/09

  24. Compton background( preliminary) • Hall C radio-activity is installed in GEANT3 (Borexino measurements) • 1.5 108 gammas cross 1 m2 per day • This reduces to 6 gammas per day crossing our field of view. • In 1 years: 2000 crossing ( neglecting detector self-screening factor of 400 !!) produce: (based on 50 years stat) - 2 Compton micro-tracksin each layer - 0.6-1 have grains in both layers - but: base-track association efficiency 0.05/100! • This will result in much less Compton electron background than electron from lead beta-radioactivity inside detector.( see internal note J.F 07/10/03) Jean Favier OPERA Meeting Ankara 3/04/09

  25. BRICK EVENT ( preliminary) Extension of set-up to a full brick; OK (in test) Scanning and reconstruction OK (in test) Actual time: 1hour (5600 cm2) for a tau-3h event Writes micro-tracks parameters ( or clusters ? Or both? ) towards FEDRA ? EMUREC ?(Amina) in progress…. Jean Favier OPERA Meeting Ankara 3/04/09

  26. Tau 3 hadrons Full brick Base-tracks Jean Favier OPERA Meeting Ankara 3/04/09

  27. Tau 3 hadrons 3cm Jean Favier OPERA Meeting Ankara 3/04/09

  28. Electron 2 Gev Jean Favier OPERA Meeting Ankara 3/04/09

  29. Conclusions • In simulation, no strong fog effect on efficiency. not simulated:the chemistry, stirring, etc of emulsion development! • Strong distortion effects • Grain density : not confortable • Compton not a problem inside detector; lead activity sould be dominant. Very low base-track efficiency for low energy electrons. • Soon: GENIMA neutrino events in Fedra ? Jean Favier OPERA Meeting Ankara 3/04/09