1 / 15

Plastic scintillator studies for future bb experiments

Plastic scintillator studies for future bb experiments. Ruben Saakyan University College London IDEA meeting Zaragoza 7-8 November 2005. Motivation. At least one of future bb experiments should be a “tracking calorimeter” SuperNEMO MOON A combination of the two…? ….

zamora
Download Presentation

Plastic scintillator studies for future bb experiments

An Image/Link below is provided (as is) to download presentation Download Policy: Content on the Website is provided to you AS IS for your information and personal use and may not be sold / licensed / shared on other websites without getting consent from its author. Content is provided to you AS IS for your information and personal use only. Download presentation by click this link. While downloading, if for some reason you are not able to download a presentation, the publisher may have deleted the file from their server. During download, if you can't get a presentation, the file might be deleted by the publisher.

E N D

Presentation Transcript


  1. Plastic scintillator studies for future bb experiments Ruben Saakyan University College London IDEA meeting Zaragoza 7-8 November 2005

  2. Motivation • At least one of future bb experiments should be a “tracking calorimeter” • SuperNEMO • MOON • A combination of the two…? • …. • Plastic scintillators is a good candidate • Cheap (large quantities will be needed) • Good timing resolution • Surface contamination measurement • Main task of R&D – to improve DE/E

  3. Plastic scintillator strips Advantages • Long strip ( ≥ 2m) read from both end “removes” PMTs from the sensitive part of the detector – good background wise for bb and radioactivity measurements • Especially for isotopes with long T1/22n • 130Te, 136Xe, 82Se… • Fewer PMT channels “Standard” readout method • Continuation of successful studies of plastic scintillator blocks funded by PPARC (seed corn money) • “Standard” method of WLS readout will not work for our needs (impossible to get more than ~40-50 p.e./MeV)

  4. ILIAS money spent for the project Total award 19200

  5. The Setup Left PMT Right PMT -100cm -80cm -60cm -40cm -20cm +20cm +40cm +60cm +80cm +100cm 0 0 207Bi AND/OR Scintillator material: polyvinyltoluene (PVT) from Bicron Existing DAQ electronics (CAMAC+NIM) and 207Bi source used

  6. The Method

  7. The measurement Subtracted electron spectra (sum from both ends)

  8. Single sided readout

  9. L/R ratio. Attenuation length. “Effective” attenuation length – 170 cm

  10. Energy resolution 400 p.e.

  11. Can we use timing from 2 pmts to reconstruct Z-coordinate? (Rpmt – Lpmt) time difference as a function of the source position Can reconstruct the position of the source within ~ 5cm (inclusive measurement)

  12. Time resolution s = 1ns ~9 cm The resolution is mainly determined by compton electrons from gammas. If e-like events can be identified the timing resolution should improve a lot and 5-10 cm accuracy (3s) might be reachable. An interesting possibility for background rejection

  13. Summary • At leastDE/E = 11% @ 1MeV (FWHM) is achievable with plastic scintillator strips of ≥ 2m. • Further improvements are likely to be possible with modest R&D • Reflective coating • Scintillator-PMT coupling • Z-reconstruction can be used for background rejection • Simulations are needed to determine requirements (DE/E, Dt/t etc…)for a particular bb experiment or contamination measurement • How to integrate this work into IDEA “official” activities

More Related